Fluid Rate Calculator Cat

Cat Fluid Therapy Rate Calculator .cat-fluid-calculator-container { font-family: -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, Helvetica, Arial, sans-serif; max-width: 800px; margin: 0 auto; padding: 20px; background: #f9f9f9; border-radius: 8px; border: 1px solid #e0e0e0; } .cat-fluid-calculator-container h2 { color: #2c3e50; text-align: center; margin-bottom: 20px; } .form-group { margin-bottom: 15px; background: #fff; padding: 15px; border-radius: 6px; box-shadow: 0 1px 3px rgba(0,0,0,0.05); } .form-group label { display: block; margin-bottom: 8px; font-weight: 600; color: #444; } .form-group input, .form-group select { width: 100%; padding: 10px; border: 1px solid #ccc; border-radius: 4px; font-size: 16px; box-sizing: border-box; } .form-group .help-text { font-size: 12px; color: #777; margin-top: 5px; } .calc-btn { width: 100%; padding: 12px; background-color: #3498db; color: white; border: none; border-radius: 4px; font-size: 18px; font-weight: bold; cursor: pointer; transition: background 0.3s; } .calc-btn:hover { background-color: #2980b9; } .results-area { margin-top: 25px; background: #fff; border: 1px solid #ddd; border-radius: 6px; padding: 20px; display: none; } .results-area h3 { margin-top: 0; color: #2c3e50; border-bottom: 2px solid #3498db; padding-bottom: 10px; } .result-row { display: flex; justify-content: space-between; padding: 10px 0; border-bottom: 1px solid #eee; } .result-row:last-child { border-bottom: none; } .result-label { font-weight: 600; color: #555; } .result-value { font-weight: 700; color: #2c3e50; } .highlight-result { background-color: #e8f6f3; padding: 15px; border-radius: 5px; margin-top: 10px; border: 1px solid #a2d9ce; } .highlight-result .result-value { color: #16a085; font-size: 1.2em; } .error-msg { color: #e74c3c; text-align: center; margin-top: 10px; display: none; } .article-content { margin-top: 40px; line-height: 1.6; color: #333; } .article-content h3 { color: #2c3e50; } .article-content ul { padding-left: 20px; } .article-content li { margin-bottom: 10px; }

Cat Fluid Therapy Rate Calculator

Enter the current body weight of the cat in kilograms.
0% – Well Hydrated 5% – Mild (Tacky MM, subtle skin tent) 7% – Moderate (Dry MM, delayed skin tent) 10% – Severe (Dry MM, skin tent remains, weak pulses) 12-15% – Critical (Shock, sunken eyes)
Select clinical assessment of dehydration.
Estimate daily volume lost via vomiting, diarrhea, or polyuria.
Standard practice is 24 hours. Enter fewer hours for rapid rehydration.
60 drops/ml (Micro/Pediatric) 15 drops/ml (Macro/Standard) 20 drops/ml (Macro) 10 drops/ml (Macro)
Most cats require a 60 gtt/ml micro-drip set.
Please enter a valid weight and correction time.

Fluid Therapy Plan

Maintenance Requirement (24h): 0 ml
Dehydration Deficit Volume: 0 ml
Ongoing Losses (24h): 0 ml
Total Volume Required (24h): 0 ml
Hourly Infusion Rate: 0 ml/hr
Drip Rate: 0 drops/min
Timing: 1 drop every 0 sec

Understanding Fluid Therapy Calculations for Cats

Calculating the correct fluid rate is critical in feline veterinary medicine. Unlike dogs, cats have a smaller blood volume relative to their body weight and are significantly more prone to fluid overload, which can lead to pulmonary edema or congestive heart failure. This calculator uses the standard components of fluid therapy: Maintenance, Rehydration (Deficit), and Ongoing Losses.

1. Maintenance Fluid Rate

Maintenance fluids are required to support basic physiological functions like respiration, metabolism, and urine production. While older formulas often used 60ml/kg/day, modern feline guidelines suggest a more conservative approach for indoor, inactive cats to prevent over-hydration.

  • Formula used: 50 ml/kg/day (Approximation for adult cats).
  • Note: For kittens or extremely active cats, requirements may be higher.

2. Dehydration Deficit

This component replaces fluid that has already been lost from the body tissues. It is calculated based on the estimated percentage of dehydration assessed during the physical exam.

  • Formula: Body Weight (kg) × % Dehydration × 10 = Deficit in Liters (converted to ml in this tool).
  • Example: A 4kg cat with 5% dehydration has a deficit of 4 × 5 × 10 = 200 ml.

3. Ongoing Losses

If the patient is continuing to lose fluids through vomiting, diarrhea, or excessive urination (polyuria), these anticipated losses must be added to the fluid plan to prevent the cat from falling behind again.

Calculating the Hourly Rate

The final flow rate (ml/hr) is determined by summing the daily maintenance needs, the deficit (usually replaced over 12-24 hours), and the anticipated ongoing losses, then dividing by the number of hours in the plan.

Warning: Always monitor respiratory rate and heart rate closely when administering IV fluids to cats. If signs of fluid overload occur (increased respiratory rate/effort, chemosis), stop fluids immediately and reassess.

function calculateCatFluids() { // Inputs var weight = parseFloat(document.getElementById('catWeight').value); var dehydration = parseFloat(document.getElementById('dehydrationLevel').value); var losses = parseFloat(document.getElementById('ongoingLosses').value); var hours = parseFloat(document.getElementById('correctionTime').value); var dripFactor = parseFloat(document.getElementById('dripFactor').value); // Validation if (isNaN(weight) || weight <= 0 || isNaN(hours) || hours 0) { secondsPerDrop = 60 / dropsPerMin; } // Display Results document.getElementById('resMaint').innerHTML = Math.round(maintenanceTotal) + " ml"; document.getElementById('resDeficit').innerHTML = Math.round(deficitTotal) + " ml"; document.getElementById('resLosses').innerHTML = Math.round(losses) + " ml"; document.getElementById('resTotal').innerHTML = Math.round(total24hVolume) + " ml"; document.getElementById('resHourlyRate').innerHTML = finalHourlyRate.toFixed(1) + " ml/hr"; document.getElementById('resDripRate').innerHTML = Math.round(dropsPerMin) + " gtt/min"; if (secondsPerDrop > 0 && isFinite(secondsPerDrop)) { document.getElementById('resSeconds').innerHTML = "1 drop every " + secondsPerDrop.toFixed(1) + " sec"; } else { document.getElementById('resSeconds').innerHTML = "No flow"; } }

Leave a Comment