How to Calculate Air Exchange Rate per Hour

Air Exchange Rate (ACH) Calculator body { font-family: -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, Helvetica, Arial, sans-serif; line-height: 1.6; color: #333; max-width: 1200px; margin: 0 auto; padding: 20px; background-color: #f9f9f9; } .calculator-container { background: #ffffff; border: 1px solid #e0e0e0; border-radius: 8px; padding: 30px; max-width: 600px; margin: 20px auto; box-shadow: 0 4px 6px rgba(0,0,0,0.05); } .calculator-title { text-align: center; margin-bottom: 25px; color: #2c3e50; font-size: 24px; font-weight: 700; border-bottom: 2px solid #3498db; padding-bottom: 10px; display: inline-block; width: 100%; } .form-group { margin-bottom: 20px; } .form-group label { display: block; margin-bottom: 8px; font-weight: 600; color: #555; } .input-wrapper { position: relative; } .form-control { width: 100%; padding: 12px; border: 1px solid #ccc; border-radius: 4px; font-size: 16px; box-sizing: border-box; transition: border-color 0.3s; } .form-control:focus { border-color: #3498db; outline: none; } .unit-label { position: absolute; right: 12px; top: 50%; transform: translateY(-50%); color: #888; font-size: 14px; pointer-events: none; } .btn-calculate { background-color: #3498db; color: white; border: none; padding: 15px 30px; font-size: 18px; font-weight: bold; border-radius: 4px; cursor: pointer; width: 100%; transition: background-color 0.3s; margin-top: 10px; } .btn-calculate:hover { background-color: #2980b9; } .results-section { margin-top: 30px; background-color: #f0f7fb; padding: 20px; border-radius: 4px; border-left: 5px solid #3498db; display: none; } .result-row { display: flex; justify-content: space-between; margin-bottom: 10px; padding-bottom: 10px; border-bottom: 1px solid #dae1e7; } .result-row:last-child { border-bottom: none; margin-bottom: 0; padding-bottom: 0; } .result-label { font-weight: 600; color: #555; } .result-value { font-weight: 700; color: #2c3e50; font-size: 18px; } .highlight-result { color: #e74c3c; font-size: 22px; } .article-content { background: #fff; padding: 40px; margin-top: 40px; border-radius: 8px; box-shadow: 0 2px 4px rgba(0,0,0,0.05); } h2 { color: #2c3e50; margin-top: 30px; border-bottom: 1px solid #eee; padding-bottom: 10px; } p { margin-bottom: 15px; color: #444; } ul { margin-bottom: 20px; padding-left: 20px; } li { margin-bottom: 8px; } .info-table { width: 100%; border-collapse: collapse; margin: 20px 0; } .info-table th, .info-table td { border: 1px solid #ddd; padding: 12px; text-align: left; } .info-table th { background-color: #f2f2f2; font-weight: 600; } .error-msg { color: #e74c3c; font-size: 14px; margin-top: 5px; display: none; } @media (max-width: 600px) { .article-content { padding: 20px; } .calculator-container { padding: 20px; } }

Air Exchange Rate (ACH) Calculator

ft
ft
ft
CFM
Cubic Feet per Minute rating of your fan or HVAC system.
Please enter valid positive numbers for all fields.
Room Volume: 0 ft³
Airflow per Hour: 0 ft³/hr
Time for 1 Air Change: 0 min
Air Changes Per Hour (ACH): 0.00
function calculateACH() { // Get input elements var lengthInput = document.getElementById('roomLength'); var widthInput = document.getElementById('roomWidth'); var heightInput = document.getElementById('roomHeight'); var cfmInput = document.getElementById('systemCFM'); var errorMsg = document.getElementById('errorMsg'); var resultsDiv = document.getElementById('results'); // Parse values var length = parseFloat(lengthInput.value); var width = parseFloat(widthInput.value); var height = parseFloat(heightInput.value); var cfm = parseFloat(cfmInput.value); // Validation if (isNaN(length) || length <= 0 || isNaN(width) || width <= 0 || isNaN(height) || height <= 0 || isNaN(cfm) || cfm <= 0) { errorMsg.style.display = 'block'; resultsDiv.style.display = 'none'; return; } errorMsg.style.display = 'none'; // Calculations // 1. Calculate Volume in Cubic Feet var volume = length * width * height; // 2. Calculate Cubic Feet per Hour (CFH) var cfh = cfm * 60; // 3. Calculate Air Changes per Hour (ACH) = (CFM * 60) / Volume var ach = cfh / volume; // 4. Time for one complete air change in minutes var timePerChange = 60 / ach; // Display Results document.getElementById('resVolume').textContent = volume.toLocaleString('en-US', {maximumFractionDigits: 0}) + " ft³"; document.getElementById('resAirflowHour').textContent = cfh.toLocaleString('en-US', {maximumFractionDigits: 0}) + " ft³/hr"; // Format time logic var timeDisplay = ""; if (timePerChange < 1) { timeDisplay = (timePerChange * 60).toFixed(1) + " seconds"; } else { timeDisplay = timePerChange.toFixed(1) + " minutes"; } document.getElementById('resTimePerChange').textContent = timeDisplay; document.getElementById('resACH').textContent = ach.toFixed(2); // Show results resultsDiv.style.display = 'block'; }

How to Calculate Air Exchange Rate per Hour

Calculating the Air Exchange Rate per Hour (often referred to as ACH or ACPH) is a critical step in ensuring proper ventilation for residential homes, commercial buildings, and industrial spaces. The Air Exchange Rate measures how many times the entire volume of air within a specific room or space is replaced with new air every hour.

Whether you are installing a new HVAC system, setting up an air purifier, or ensuring safety compliance in a workshop, understanding your ACH is vital for maintaining healthy Indoor Air Quality (IAQ).

The Air Exchange Rate Formula

To calculate the Air Changes per Hour manually, you need two primary pieces of data: the volume of the room and the airflow capacity of your ventilation equipment (usually measured in Cubic Feet per Minute, or CFM).

ACH Formula:
ACH = (CFM × 60) / Volume of Room

Step-by-Step Calculation Guide:

  1. Measure Room Dimensions: Measure the Length, Width, and Height of the room in feet.
  2. Calculate Room Volume: Multiply Length × Width × Height to get the volume in cubic feet (ft³).
  3. Determine Airflow (CFM): Check the specifications of your fan, air purifier, or HVAC system to find its CFM rating.
  4. Convert CFM to CFH: Multiply the CFM by 60 (since there are 60 minutes in an hour) to get Cubic Feet per Hour.
  5. Divide: Divide the total hourly airflow by the room volume.

Calculation Example

Let's say you have a living room that is 20 feet long, 15 feet wide, and has an 8-foot ceiling. You are using an air purifier rated at 300 CFM.

  • Step 1 (Volume): 20 × 15 × 8 = 2,400 cubic feet.
  • Step 2 (Hourly Airflow): 300 CFM × 60 minutes = 18,000 cubic feet per hour.
  • Step 3 (ACH): 18,000 / 2,400 = 7.5 ACH.

This means the air in your living room is completely replaced 7.5 times every hour, or roughly once every 8 minutes.

Recommended Air Exchange Rates

Different spaces require different levels of ventilation depending on their usage and the presence of pollutants. Below are general guidelines for recommended ACH levels:

Room Type Recommended ACH
Residential Bedroom 2 – 4
Kitchens 15 – 20
Bathrooms 6 – 10
Offices 4 – 6
Laboratories/Workshops 6 – 12
Warehouses 1 – 2

Why is Air Exchange Important?

1. Pollutant Removal: High ACH helps dilute and remove airborne contaminants like dust, allergens, VOCs (Volatile Organic Compounds), and viruses.

2. Humidity Control: Proper air exchange prevents moisture buildup, reducing the risk of mold growth, particularly in bathrooms and basements.

3. CO2 Reduction: In crowded spaces, CO2 levels can rise quickly, causing drowsiness and reduced cognitive function. Adequate fresh air exchange keeps CO2 levels low.

Factors That Affect ACH

While the calculation provides a theoretical number, real-world performance can be influenced by:

  • Obstructions: Furniture and layout can impede airflow circulation.
  • Leakage: Drafty windows or poor insulation can introduce uncontrolled air exchange (infiltration).
  • System Efficiency: Clogged filters or dirty ducts reduce the actual CFM of your HVAC system.

Leave a Comment