Theoretical Flow Rate Calculator

Theoretical Flow Rate Calculator body { font-family: -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, Helvetica, Arial, sans-serif; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; background-color: #f9f9f9; } .calculator-wrapper { background: #ffffff; border-radius: 12px; box-shadow: 0 4px 20px rgba(0,0,0,0.1); padding: 30px; margin-bottom: 40px; border: 1px solid #e0e0e0; } .calc-title { text-align: center; color: #2c3e50; margin-bottom: 25px; font-size: 24px; font-weight: 700; } .input-group { margin-bottom: 20px; } .input-group label { display: block; margin-bottom: 8px; font-weight: 600; color: #4a5568; } .input-row { display: flex; gap: 15px; } .input-field { flex: 1; padding: 12px 15px; border: 2px solid #e2e8f0; border-radius: 8px; font-size: 16px; transition: border-color 0.2s; } .input-field:focus { border-color: #3182ce; outline: none; } select.input-field { background-color: #fff; cursor: pointer; } .calc-btn { width: 100%; background-color: #3182ce; color: white; border: none; padding: 15px; font-size: 18px; font-weight: 600; border-radius: 8px; cursor: pointer; transition: background-color 0.2s; margin-top: 10px; } .calc-btn:hover { background-color: #2c5282; } .results-box { background-color: #ebf8ff; border-radius: 8px; padding: 25px; margin-top: 25px; border-left: 5px solid #3182ce; display: none; } .result-row { display: flex; justify-content: space-between; align-items: center; margin-bottom: 12px; padding-bottom: 12px; border-bottom: 1px solid #bee3f8; } .result-row:last-child { border-bottom: none; margin-bottom: 0; padding-bottom: 0; } .result-label { font-weight: 600; color: #2d3748; } .result-value { font-size: 20px; font-weight: 700; color: #2b6cb0; } .article-content h2 { color: #2c3e50; margin-top: 30px; border-bottom: 2px solid #eee; padding-bottom: 10px; } .article-content p { margin-bottom: 15px; color: #4a5568; } .formula-box { background: #f1f5f9; padding: 15px; border-radius: 6px; font-family: "Courier New", monospace; margin: 15px 0; border: 1px solid #cbd5e1; } .error-msg { color: #e53e3e; font-size: 14px; margin-top: 5px; display: none; }
Theoretical Hydraulic Flow Rate Calculator
cc / rev in³ / rev
Please enter a valid displacement.
Please enter a valid RPM.
Metric Flow Rate: 0 LPM
US Gallons Flow Rate: 0 GPM
Imperial Gallons Flow Rate: 0 Imp GPM

Understanding Theoretical Flow Rate

The theoretical flow rate of a positive displacement pump is a fundamental calculation in hydraulic engineering. It represents the volume of fluid a pump transports over a specific period, assuming 100% efficiency. This value is purely geometric, based on the internal dimensions of the pump and the speed at which it rotates.

Engineers use this metric as a baseline to size components such as motors, valves, and actuators. While actual flow rate will always be slightly lower due to internal leakage (slip) and fluid properties, the theoretical flow rate determines the maximum potential capacity of the system.

The Formula

The calculation depends on the unit system used for the pump's displacement (volume moved per single revolution of the shaft).

Metric System (cc/rev)

Q (LPM) = (d × n) / 1000

Where:
Q = Theoretical Flow Rate in Liters per Minute (LPM)
d = Displacement in cubic centimeters per revolution (cc/rev)
n = Rotational Speed in Revolutions per Minute (RPM)
1000 = Conversion factor from cc to Liters

Imperial System (in³/rev)

Q (GPM) = (d × n) / 231

Where:
Q = Theoretical Flow Rate in US Gallons per Minute (GPM)
d = Displacement in cubic inches per revolution (in³/rev)
n = Rotational Speed in RPM
231 = Conversion factor (231 cubic inches = 1 US Gallon)

Theoretical vs. Actual Flow

It is critical to distinguish between Theoretical Flow and Actual Flow.

  • Theoretical Flow: Assumes zero leakage and perfect sealing. It is the geometric volume displaced.
  • Actual Flow: The real output measured at the pump outlet. It is always less than theoretical flow due to internal leakage (slip) as pressure increases.

The relationship is defined by Volumetric Efficiency (ηvol):
Actual Flow = Theoretical Flow × Volumetric Efficiency.

Example Calculation

Consider a hydraulic gear pump with a displacement of 50 cc/rev driven by an electric motor at 1450 RPM.

Using the formula:
Q = (50 × 1450) / 1000
Q = 72,500 / 1000
Q = 72.5 LPM

This means, theoretically, the pump will move 72.5 liters of oil every minute. If the pump is 95% efficient, the actual flow would be roughly 68.9 LPM.

function calculateTheoreticalFlow() { // 1. Get Input Elements var dispInput = document.getElementById('displacement'); var unitInput = document.getElementById('dispUnit'); var rpmInput = document.getElementById('rpm'); var resultsBox = document.getElementById('results'); var dispError = document.getElementById('dispError'); var rpmError = document.getElementById('rpmError'); var resLPM = document.getElementById('resLPM'); var resGPM = document.getElementById('resGPM'); var resImpGPM = document.getElementById('resImpGPM'); // 2. Reset Errors dispError.style.display = 'none'; rpmError.style.display = 'none'; resultsBox.style.display = 'none'; dispInput.style.borderColor = '#e2e8f0'; rpmInput.style.borderColor = '#e2e8f0'; // 3. Get Values and Parse var displacement = parseFloat(dispInput.value); var unit = unitInput.value; var rpm = parseFloat(rpmInput.value); var isValid = true; // 4. Validation Logic if (isNaN(displacement) || displacement <= 0) { dispError.style.display = 'block'; dispInput.style.borderColor = '#e53e3e'; isValid = false; } if (isNaN(rpm) || rpm < 0) { rpmError.style.display = 'block'; rpmInput.style.borderColor = '#e53e3e'; isValid = false; } if (!isValid) return; // 5. Calculation Logic var flowLPM = 0; var flowGPM = 0; var flowImpGPM = 0; // Convert everything to basic Metric (LPM) first, then convert out if (unit === 'cc') { // Formula: (cc/rev * rpm) / 1000 = LPM flowLPM = (displacement * rpm) / 1000; } else if (unit === 'cir') { // Formula: (in3/rev * rpm) / 231 = GPM (US) // Then convert GPM to LPM flowGPM = (displacement * rpm) / 231; flowLPM = flowGPM * 3.78541; // Convert US GPM to LPM } // 6. Final Conversions for Output // If we started with cc, we have LPM, need GPM if (unit === 'cc') { flowGPM = flowLPM / 3.78541; } // Imperial Gallons (UK) // 1 Imp Gallon = 4.54609 Liters flowImpGPM = flowLPM / 4.54609; // 7. Display Results resLPM.innerText = flowLPM.toFixed(2) + " LPM"; resGPM.innerText = flowGPM.toFixed(2) + " GPM"; resImpGPM.innerText = flowImpGPM.toFixed(2) + " Imp GPM"; resultsBox.style.display = 'block'; }