Ac Load Calculator

AC Load Calculator: Calculate Your Electrical Load Needs body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; line-height: 1.6; color: #333; background-color: #f8f9fa; margin: 0; padding: 0; } .container { max-width: 1000px; margin: 20px auto; padding: 25px; background-color: #fff; border-radius: 8px; box-shadow: 0 2px 10px rgba(0, 0, 0, 0.1); } h1, h2, h3 { color: #004a99; text-align: center; } h1 { margin-bottom: 15px; font-size: 2.2em; } h2 { margin-top: 30px; margin-bottom: 20px; font-size: 1.8em; border-bottom: 2px solid #004a99; padding-bottom: 5px; } h3 { margin-top: 25px; margin-bottom: 15px; font-size: 1.4em; } .loan-calc-container { background-color: #eef4fa; padding: 25px; border-radius: 8px; margin-bottom: 30px; border: 1px solid #cce0ff; } .input-group { margin-bottom: 20px; text-align: left; } .input-group label { display: block; margin-bottom: 8px; font-weight: bold; color: #004a99; } .input-group input[type="number"], .input-group select { width: calc(100% – 22px); padding: 10px; border: 1px solid #ccc; border-radius: 4px; box-sizing: border-box; font-size: 1em; } .input-group select { cursor: pointer; } .input-group small { display: block; margin-top: 5px; color: #666; font-size: 0.9em; } .error-message { color: #dc3545; font-size: 0.9em; margin-top: 5px; height: 18px; /* Reserve space for error message */ } button { background-color: #004a99; color: white; border: none; padding: 12px 25px; border-radius: 5px; cursor: pointer; font-size: 1em; margin: 5px; transition: background-color 0.3s ease; } button:hover { background-color: #003a7a; } #result, #intermediate-results div { background-color: #d4edda; color: #155724; border: 1px solid #c3e6cb; padding: 15px; border-radius: 5px; margin-top: 20px; text-align: center; font-size: 1.2em; } #result h3 { margin-top: 0; color: #155724; text-align: center; } #intermediate-results { margin-top: 25px; padding: 15px; border-radius: 5px; background-color: #f0f0f0; border: 1px solid #ddd; } #intermediate-results h3 { margin-top: 0; color: #333; text-align: center; } #intermediate-results div { margin-bottom: 10px; background-color: #fff; border: 1px solid #eee; padding: 10px; font-size: 1.1em; display: flex; justify-content: space-between; align-items: center; } #intermediate-results div span:first-child { font-weight: bold; } #intermediate-results div span:last-child { font-weight: normal; color: #555; } .formula-explanation { margin-top: 20px; font-style: italic; color: #555; text-align: center; font-size: 0.95em; } .chart-container { width: 100%; max-width: 800px; margin: 30px auto; background-color: #fff; padding: 20px; border-radius: 8px; box-shadow: 0 2px 5px rgba(0,0,0,0.1); } caption { font-size: 1.1em; margin-bottom: 10px; font-weight: bold; color: #004a99; text-align: left; } table { width: 100%; border-collapse: collapse; margin-top: 15px; } th, td { border: 1px solid #ddd; padding: 10px; text-align: right; } th { background-color: #004a99; color: white; text-align: center; } td { background-color: #f2f8ff; } td:first-child, th:first-child { text-align: left; } .article-content { margin-top: 40px; background-color: #fff; padding: 30px; border-radius: 8px; box-shadow: 0 2px 10px rgba(0,0,0,0.1); } .article-content h2 { text-align: left; border-bottom: 2px solid #004a99; margin-top: 30px; } .article-content p { margin-bottom: 15px; } .article-content ul, .article-content ol { margin-left: 25px; margin-bottom: 15px; } .article-content li { margin-bottom: 8px; } .faq-item { margin-bottom: 15px; } .faq-item strong { display: block; color: #004a99; margin-bottom: 5px; } .chart-legend { text-align: center; margin-top: 10px; font-size: 0.9em; } .chart-legend span { display: inline-block; margin: 0 15px; } .chart-legend div { display: inline-block; width: 15px; height: 15px; margin-right: 5px; vertical-align: middle; } .color-watts { background-color: #1f77b4; } /* Muted blue */ .color-amps { background-color: #ff7f0e; } /* Safety orange */ .color-breaker { background-color: #d62728; } /* Brick red */ /* Specific styling for the AC Load Calculator */ .ac-calc-input-label { color: #0056b3; /* Slightly different shade for emphasis */ font-weight: bold; } .ac-calc-helper-text { color: #555; font-size: 0.85em; }

AC Load Calculator

Accurately determine the electrical load for your air conditioning systems.

AC Load Calculation Inputs

Enter the cooling output of your AC unit in British Thermal Units per hour.
Enter the EER (Energy Efficiency Ratio) or SEER (Seasonal Energy Efficiency Ratio) of your AC unit. Higher is better.
0.8 (Typical for AC) 0.7 0.9 1.0 (Resistive Load – Rare for AC) Represents the ratio of real power to apparent power. Usually around 0.8 for AC units.
120V (Standard Residential) 208V 230V (Common Residential) 240V 277V 480V (Commercial) The operating voltage of your electrical system. Common residential voltages are 120V or 240V.
A multiplier to ensure the breaker or fuse is rated higher than the continuous load (e.g., 1.25 for 125%).

Key Calculations

Real Power (Watts):
Apparent Power (VA):
Running Amperage (A):

Recommended Breaker Size (Amps)

Formula Used: Watts = (BTU/hr) / (3.412 BTU/Wh) VA = Watts / Power Factor Amps = VA / Voltage Recommended Breaker Size = Amps * Safety Factor

Watts
Amps
Breaker Size (Approx.)
AC Load Calculation Summary
Metric Value Unit Notes
Cooling Capacity BTU/hr Input: AC Unit Capacity
Energy Efficiency Ratio EER/SEER Input: AC Unit Efficiency
Real Power Watts (W) Actual power consumed by the AC.
Apparent Power Volt-Amperes (VA) Total power supplied, including reactive power.
Running Amperage Amperes (A) Current drawn during normal operation.
Recommended Breaker Size Amperes (A) Calculated for safe circuit protection.

What is an AC Load Calculator?

An AC load calculator is a specialized tool designed to help homeowners, electricians, and HVAC professionals determine the electrical power requirements for air conditioning units. It translates the cooling capacity of an AC system (measured in BTU/hr) and its energy efficiency into essential electrical metrics like watts, volt-amperes (VA), running amperage, and ultimately, the recommended circuit breaker size. Understanding the electrical load is crucial for ensuring the safety, efficiency, and longevity of your electrical system and HVAC equipment. This tool simplifies complex electrical calculations, making it accessible to a broader audience.

Anyone installing, upgrading, or troubleshooting an air conditioning system should consider using an AC load calculator. This includes:

  • Homeowners planning to install a new AC unit or add a sub-panel.
  • Electricians sizing circuits, breakers, and wiring for HVAC installations.
  • HVAC technicians diagnosing power issues or ensuring correct equipment matching.
  • Contractors estimating electrical needs for construction or renovation projects.

Common misconceptions about AC electrical load include assuming that a higher BTU rating directly translates to a proportional increase in amperage without considering efficiency (EER/SEER) or voltage. Another misconception is that the breaker size should exactly match the running amperage; in reality, electrical codes mandate a safety margin (often 25%) for continuous loads. This calculator helps clarify these aspects.

AC Load Calculator Formula and Mathematical Explanation

The AC load calculator works by converting the cooling output of an air conditioner into electrical power units. The process involves several key steps, taking into account efficiency, voltage, and power factor.

Step 1: Convert BTU/hr to Watts (Real Power) Air conditioning capacity is typically rated in British Thermal Units per hour (BTU/hr), which measures heat removal. To find the electrical power consumed, we convert BTU/hr to Watts. The conversion factor is approximately 3.412 BTU per Watt-hour. Watts (W) = Cooling Capacity (BTU/hr) / 3.412

Step 2: Calculate Apparent Power (VA) Electrical power has two components: real power (Watts), which does the actual work, and reactive power, which is necessary for devices with motors and coils like AC compressors. The combination of real and reactive power is called apparent power, measured in Volt-Amperes (VA). The power factor (PF) is the ratio of real power to apparent power. Apparent Power (VA) = Real Power (Watts) / Power Factor (PF) A typical power factor for AC units is around 0.8, meaning the apparent power is higher than the real power.

Step 3: Calculate Running Amperage Amperage (current) is the flow of electrical charge. It's calculated by dividing the apparent power (VA) by the system voltage (V). Running Amperage (A) = Apparent Power (VA) / Voltage (V) This value represents the current the AC unit draws under normal operating conditions.

Step 4: Determine Recommended Breaker Size Electrical codes (like the NEC in the US) require that circuit breakers and conductors be sized to handle 125% of the continuous load to prevent overheating and ensure safety. The safety factor (often 1.25) is applied to the calculated running amperage. Recommended Breaker Size (A) = Running Amperage (A) * Safety Factor (e.g., 1.25) The result is the minimum ampere rating for the circuit breaker protecting the AC unit.

Variables Table

Variable Meaning Unit Typical Range / Values
Cooling Capacity The rate at which the AC unit can remove heat. BTU/hr 6,000 – 36,000+
Energy Efficiency Rating (EER/SEER) Measures the AC unit's energy efficiency. Higher values indicate better efficiency. Unitless (Ratio) 8 – 25+
Power Factor (PF) Ratio of real power to apparent power; indicates how effectively electrical power is being converted into useful work. Unitless (0 to 1) 0.7 – 0.9 (Typical for AC); 1.0 for purely resistive loads.
System Voltage (V) The nominal operating voltage of the electrical circuit. Volts (V) 120V, 208V, 230V, 240V, 277V, 480V
Safety Factor Multiplier applied to continuous load current for circuit protection, typically 125% (1.25). Unitless 1.25 (Standard); Varies by code and application.
Real Power (Watts) The actual power consumed by the AC unit to perform cooling. Watts (W) Calculated result.
Apparent Power (VA) The total power supplied to the AC unit, including real and reactive power. Volt-Amperes (VA) Calculated result.
Running Amperage The current drawn by the AC unit during operation. Amperes (A) Calculated result.
Recommended Breaker Size The minimum ampere rating for the circuit breaker protecting the AC unit. Amperes (A) Calculated result.

Practical Examples (Real-World Use Cases)

Understanding the AC load calculator with practical examples helps illustrate its importance.

Example 1: Standard Residential Split System

Consider a homeowner installing a new 18,000 BTU/hr split AC system with an EER of 12. The home uses a standard 240V electrical service, and the electrician aims to follow the 125% safety factor rule. The power factor is estimated at 0.8.

  • Inputs:
  • Cooling Capacity: 18,000 BTU/hr
  • Efficiency Rating (EER): 12
  • Power Factor: 0.8
  • System Voltage: 240V
  • Safety Factor: 1.25

Calculations:

  • Watts = 18,000 / 3.412 ≈ 5,275 W
  • VA = 5,275 / 0.8 ≈ 6,594 VA
  • Running Amperage = 6,594 / 240V ≈ 27.48 A
  • Recommended Breaker Size = 27.48 A * 1.25 ≈ 34.35 A

Interpretation: This 18,000 BTU AC unit consumes approximately 5,275 Watts of real power and draws about 27.5 Amps while running. For safe operation, a circuit breaker rated at least 35 Amps (rounding up to the next standard size) on a 240V circuit is recommended. The calculation highlights that the breaker size is significantly higher than the running amperage due to the safety factor required for continuous loads.

Example 2: Smaller Window AC Unit

A resident is installing a 10,000 BTU/hr window AC unit with an EER of 10 in a room served by a 120V outlet. The power factor is assumed to be 0.75, and a safety factor of 1.25 is applied.

  • Inputs:
  • Cooling Capacity: 10,000 BTU/hr
  • Efficiency Rating (EER): 10
  • Power Factor: 0.75
  • System Voltage: 120V
  • Safety Factor: 1.25

Calculations:

  • Watts = 10,000 / 3.412 ≈ 2,931 W
  • VA = 2,931 / 0.75 ≈ 3,908 VA
  • Running Amperage = 3,908 / 120V ≈ 32.57 A
  • Recommended Breaker Size = 32.57 A * 1.25 ≈ 40.71 A

Interpretation: This smaller unit requires approximately 2,931 Watts and draws around 32.6 Amps at 120V. The calculated breaker size is about 41 Amps. This result suggests that a standard 15A or 20A circuit typically found for outlets might be insufficient for the continuous load. It indicates the need for a dedicated circuit, potentially requiring a 40A breaker (next standard size up) if code allows for such high amperage on a 120V circuit for this load, or reconsideration of the unit's suitability for the existing electrical infrastructure. This example emphasizes how efficiency and voltage significantly impact amperage.

How to Use This AC Load Calculator

Using the AC load calculator is straightforward. Follow these steps to get accurate electrical load estimations for your air conditioning needs:

  1. Locate AC Unit Specifications: Find the cooling capacity (BTU/hr) and the Energy Efficiency Ratio (EER or SEER) from your AC unit's nameplate, manual, or manufacturer's website.
  2. Identify System Voltage: Determine the voltage of the electrical circuit that will power the AC unit. This is typically 120V or 240V for residential applications. Check your electrical panel or consult an electrician.
  3. Estimate Power Factor: For most AC units, a power factor of 0.8 is a reasonable estimate. If unsure, you can use this value or consult the manufacturer's specifications.
  4. Set Safety Factor: The default value of 1.25 (representing 125%) is standard for continuous loads as per electrical codes. Adjust only if you have specific requirements or professional guidance.
  5. Enter Values: Input the gathered information into the corresponding fields in the calculator: Cooling Capacity, Efficiency Rating, Power Factor, System Voltage, and Safety Factor.
  6. Calculate: Click the "Calculate Load" button.

How to Read Results:

  • Real Power (Watts): The actual energy consumed by the AC unit.
  • Apparent Power (VA): The total power the electrical system must supply.
  • Running Amperage: The current the AC unit draws during operation. This is crucial for wire sizing.
  • Recommended Breaker Size: The minimum ampere rating for the circuit breaker required to safely protect the circuit. This is the most critical output for electrical safety.

Decision-Making Guidance:

  • If the recommended breaker size is larger than your existing circuit breaker, you will need a new, dedicated circuit installed by a qualified electrician.
  • Ensure the wiring gauge is appropriate for the calculated running amperage (not the breaker size) to prevent overheating. Consult electrical codes or an electrician.
  • Comparing the calculated loads of different AC units can help in selecting the most suitable model for your home's electrical capacity.
  • Always consult a licensed electrician or HVAC professional before making any electrical modifications or installations.

Key Factors That Affect AC Load Calculator Results

Several factors influence the accuracy and outcome of an AC load calculator. Understanding these can help in interpreting the results and making informed decisions:

  • Cooling Capacity (BTU/hr): A higher BTU/hr rating signifies a more powerful AC unit capable of cooling larger spaces. Consequently, it will require more electrical power, leading to higher Watts, VA, Amps, and a larger breaker size.
  • Energy Efficiency Rating (EER/SEER): A higher EER/SEER indicates that the AC unit uses less electricity to produce the same amount of cooling. Therefore, for the same BTU/hr capacity, a more efficient unit will consume fewer Watts, draw less Amperage, and result in a smaller recommended breaker size compared to a less efficient unit. This is a critical factor in long-term operating costs and electrical load.
  • System Voltage (V): Voltage directly impacts the running amperage. For a given amount of power (VA), a lower voltage system requires a higher amperage. For instance, a 240V system will draw roughly half the amperage of a 120V system for the same power requirement, affecting wire sizing and circuit protection.
  • Power Factor (PF): This factor accounts for the difference between real power (Watts) and apparent power (VA). AC units with motors have inductive loads, leading to a power factor less than 1. A lower power factor means the system needs to supply more apparent power (VA) to deliver the same amount of real power (Watts), resulting in higher amperage draw and requiring larger conductors and breakers.
  • Continuous Load and Safety Factor: Electrical codes mandate that circuits supplying continuous loads (like AC units running for 3+ hours) must be sized at 125% of the load. This safety margin accounts for heat generated in wires and prevents nuisance tripping of breakers. Ignoring this factor can lead to unsafe installations.
  • Starting vs. Running Amperage: The calculator typically estimates the *running* amperage. However, AC units (especially those with compressors) draw a significantly higher current surge (inrush current) when they start. While this surge is temporary and doesn't usually dictate the breaker size for continuous loads, it's a factor to consider for components like Variable Frequency Drives (VFDs) or when sizing generators.
  • Altitude and Ambient Temperature: While not directly in the basic formula, extremely high altitudes or temperatures can affect AC unit performance and efficiency, potentially leading to increased power consumption. Professional HVAC load calculations often factor these in.

Frequently Asked Questions (FAQ)

Q1: What is the difference between Watts, VA, and Amps for my AC?

Watts (W) represent the real power used to do work (cooling). Volt-Amperes (VA) represent the total apparent power supplied, including reactive power needed for motors. Amps (A) represent the current flowing through the circuit. For AC units, VA and Amps are typically higher than Watts and Amps, respectively, due to the power factor.

Q2: Why is the recommended breaker size higher than the running amps?

Electrical codes (like the NEC) require circuit breakers and wiring to be sized at 125% of the continuous load. This safety margin prevents overheating and ensures reliable operation, as AC units are considered continuous loads.

Q3: Can I use my existing 15A or 20A circuit for a new AC unit?

It depends entirely on the AC unit's specifications. Many standard window AC units under 10,000 BTU might run on a 15A or 20A circuit (ensure it's dedicated), but larger central AC systems or even some powerful window units will require higher amperage circuits (e.g., 30A, 40A, 50A) and potentially a dedicated circuit. Always check the calculator's recommended breaker size and the unit's nameplate.

Q4: Does SEER rating affect the calculated load?

Yes, indirectly. A higher SEER (or EER) rating means the unit is more efficient. While the BTU/hr capacity determines the fundamental cooling power needed, a higher SEER unit will use fewer Watts and Amps to achieve that cooling capacity compared to a lower SEER unit of the same BTU/hr. Our calculator uses EER/SEER to derive the Watts more accurately.

Q5: What is a typical power factor for an air conditioner?

For most residential AC units, the power factor is typically around 0.7 to 0.85. A value of 0.8 is a common estimate used in calculations when the exact figure isn't available.

Q6: What happens if I use a breaker that's too small?

Using a breaker that's too small can cause it to trip frequently, indicating an overloaded circuit. In the worst-case scenario, if the breaker fails or is improperly sized, it could lead to overheating of the wiring, posing a significant fire risk.

Q7: Do I need a special type of circuit breaker for my AC?

Generally, a standard circuit breaker of the correct ampere rating and voltage is sufficient. However, some jurisdictions or specific installations might require specific types (e.g., GFCI or AFCI breakers for certain locations or under specific code requirements), but the primary consideration is the ampere rating based on the load calculation. Consult your local electrical codes and a qualified electrician.

Q8: How does the AC load calculator help with multiple AC units?

If you have multiple AC units, you should calculate the load for each unit individually using this calculator. The total electrical demand on your panel would be the sum of the individual running amperages (plus a diversity factor for other home loads), and each unit requires its own appropriately sized dedicated circuit and breaker. This calculator is designed for one unit at a time.

Q9: Should I use the calculator's output for wire sizing?

The calculator provides the *running amperage*. Wire sizing depends on this value, the type of wire, insulation temperature rating, conduit fill, and ambient temperature, often factoring in the 125% continuous load rule. While the calculated running amperage is a key input, always refer to NEC tables or consult an electrician for correct wire gauge selection. This calculator focuses on the breaker size determination.

Related Tools and Internal Resources

Explore these related resources to further enhance your understanding of electrical systems and energy efficiency:

© 2023 Your Company Name. All rights reserved.

var canvas = document.getElementById("acLoadChart"); var ctx = canvas.getContext("2d"); var acLoadChartInstance = null; function validateInput(id, minValue, maxValue, errorMessageElementId, label) { var input = document.getElementById(id); var value = parseFloat(input.value); var errorElement = document.getElementById(errorMessageElementId); errorElement.textContent = ""; // Clear previous error if (isNaN(value) || input.value.trim() === "") { errorElement.textContent = "Please enter a valid number."; return false; } if (value <= 0) { errorElement.textContent = "Value cannot be zero or negative."; return false; } if (minValue !== null && value maxValue) { errorElement.textContent = label + " cannot exceed " + maxValue + "."; return false; } return true; } function updateChart() { if (acLoadChartInstance) { acLoadChartInstance.destroy(); } var coolingCapacity = parseFloat(document.getElementById("coolingCapacity").value); var efficiencyRating = parseFloat(document.getElementById("efficiencyRating").value); var powerFactor = parseFloat(document.getElementById("powerFactor").value); var voltage = parseFloat(document.getElementById("voltage").value); var safetyFactor = parseFloat(document.getElementById("safetyFactor").value); // Recalculate based on current values for chart data var watts = (coolingCapacity / 3.412); var va = watts / powerFactor; var amps = va / voltage; var breakerSizeApprox = amps * safetyFactor; // Ensure values are valid numbers before plotting if (isNaN(watts) || isNaN(amps) || isNaN(breakerSizeApprox) || watts <= 0 || amps <= 0 || breakerSizeApprox <= 0) { // Don't draw chart if data is invalid return; } canvas.width = canvas.offsetWidth; // Adjust canvas size canvas.height = 300; // Fixed height for chart acLoadChartInstance = new Chart(ctx, { type: 'bar', data: { labels: ['AC Load Metrics'], datasets: [ { label: 'Watts', data: [watts], backgroundColor: 'rgba(31, 119, 180, 0.7)', // Muted blue borderColor: 'rgba(31, 119, 180, 1)', borderWidth: 1 }, { label: 'Amps (Running)', data: [amps], backgroundColor: 'rgba(255, 127, 14, 0.7)', // Safety orange borderColor: 'rgba(255, 127, 14, 1)', borderWidth: 1 }, { label: 'Breaker Size (Approx)', data: [breakerSizeApprox], backgroundColor: 'rgba(214, 39, 40, 0.7)', // Brick red borderColor: 'rgba(214, 39, 40, 1)', borderWidth: 1 } ] }, options: { responsive: true, maintainAspectRatio: false, scales: { y: { beginAtZero: true, title: { display: true, text: 'Value' } } }, plugins: { legend: { display: false // Legend is handled by the div below the chart }, title: { display: true, text: 'AC Load Breakdown' } } } }); } // Function to add Chart.js if not present function loadChartJs() { if (typeof Chart === 'undefined') { var script = document.createElement('script'); script.src = 'https://cdn.jsdelivr.net/npm/chart.js'; script.onload = function() { // Chart.js loaded, now initialize chart updateChart(); }; document.head.appendChild(script); } else { // Chart.js already loaded updateChart(); } } function calculateACLoad() { var isValid = true; isValid = validateInput("coolingCapacity", 1, null, "coolingCapacityError", "Cooling Capacity") && isValid; isValid = validateInput("efficiencyRating", 1, null, "efficiencyRatingError", "Efficiency Rating") && isValid; isValid = validateInput("safetyFactor", 1, null, "safetyFactorError", "Safety Factor") && isValid; // Power Factor and Voltage are selects, so validation is less critical for non-numeric, // but we still ensure they have values. var pfSelect = document.getElementById("powerFactor"); if (pfSelect.value === "") { document.getElementById("powerFactorError").textContent = "Please select a Power Factor."; isValid = false; } var voltageSelect = document.getElementById("voltage"); if (voltageSelect.value === "") { document.getElementById("voltageError").textContent = "Please select a System Voltage."; isValid = false; } if (!isValid) { // Clear results if inputs are invalid document.getElementById("wattsValue").textContent = "–"; document.getElementById("vaValue").textContent = "–"; document.getElementById("ampsValue").textContent = "–"; document.getElementById("breakerSizeValue").textContent = "–"; clearTable(); return; } var coolingCapacity = parseFloat(document.getElementById("coolingCapacity").value); var efficiencyRating = parseFloat(document.getElementById("efficiencyRating").value); var powerFactor = parseFloat(document.getElementById("powerFactor").value); var voltage = parseFloat(document.getElementById("voltage").value); var safetyFactor = parseFloat(document.getElementById("safetyFactor").value); // Calculations var watts = coolingCapacity / 3.412; var va = watts / powerFactor; var amps = va / voltage; var breakerSize = amps * safetyFactor; // Display intermediate results document.getElementById("wattsValue").textContent = watts.toFixed(2); document.getElementById("vaValue").textContent = va.toFixed(2); document.getElementById("ampsValue").textContent = amps.toFixed(2); // Display primary result document.getElementById("breakerSizeValue").textContent = breakerSize.toFixed(2) + " A"; // Update table document.getElementById("tblCoolingCapacity").textContent = coolingCapacity; document.getElementById("tblEfficiencyRating").textContent = efficiencyRating; document.getElementById("tblWatts").textContent = watts.toFixed(2); document.getElementById("tblVA").textContent = va.toFixed(2); document.getElementById("tblAmps").textContent = amps.toFixed(2); document.getElementById("tblBreakerSize").textContent = breakerSize.toFixed(2); // Update chart loadChartJs(); } function clearTable() { document.getElementById("tblCoolingCapacity").textContent = "–"; document.getElementById("tblEfficiencyRating").textContent = "–"; document.getElementById("tblWatts").textContent = "–"; document.getElementById("tblVA").textContent = "–"; document.getElementById("tblAmps").textContent = "–"; document.getElementById("tblBreakerSize").textContent = "–"; } function resetACLoad() { document.getElementById("coolingCapacity").value = "12000"; document.getElementById("efficiencyRating").value = "10"; document.getElementById("powerFactor").value = "0.8"; document.getElementById("voltage").value = "120"; document.getElementById("safetyFactor").value = "1.25"; // Clear errors document.getElementById("coolingCapacityError").textContent = ""; document.getElementById("efficiencyRatingError").textContent = ""; document.getElementById("powerFactorError").textContent = ""; document.getElementById("voltageError").textContent = ""; document.getElementById("safetyFactorError").textContent = ""; // Clear results and table document.getElementById("wattsValue").textContent = "–"; document.getElementById("vaValue").textContent = "–"; document.getElementById("ampsValue").textContent = "–"; document.getElementById("breakerSizeValue").textContent = "–"; clearTable(); // Clear chart if (acLoadChartInstance) { acLoadChartInstance.destroy(); acLoadChartInstance = null; } var canvas = document.getElementById("acLoadChart"); var ctx = canvas.getContext("2d"); ctx.clearRect(0, 0, canvas.width, canvas.height); // Clear canvas drawing } function copyResults() { var watts = document.getElementById("wattsValue").textContent; var va = document.getElementById("vaValue").textContent; var amps = document.getElementById("ampsValue").textContent; var breakerSize = document.getElementById("breakerSizeValue").textContent; var coolingCapacity = document.getElementById("coolingCapacity").value; var efficiencyRating = document.getElementById("efficiencyRating").value; var powerFactor = document.getElementById("powerFactor").value; var voltage = document.getElementById("voltage").value; var safetyFactor = document.getElementById("safetyFactor").value; var resultText = "AC Load Calculation Results:\n\n"; resultText += "Primary Result (Recommended Breaker Size): " + breakerSize + "\n"; resultText += "—————————————–\n"; resultText += "Key Intermediate Values:\n"; resultText += "- Real Power (Watts): " + watts + " W\n"; resultText += "- Apparent Power (VA): " + va + "\n"; resultText += "- Running Amperage: " + amps + " A\n"; resultText += "\n"; resultText += "Input Assumptions:\n"; resultText += "- Cooling Capacity: " + coolingCapacity + " BTU/hr\n"; resultText += "- Efficiency Rating (EER/SEER): " + efficiencyRating + "\n"; resultText += "- Power Factor: " + powerFactor + "\n"; resultText += "- System Voltage: " + voltage + " V\n"; resultText += "- Safety Factor: " + safetyFactor + "\n"; // Use a temporary textarea to copy text var textArea = document.createElement("textarea"); textArea.value = resultText; textArea.style.position = "fixed"; // Avoid scrolling to bottom textArea.style.left = "-9999px"; document.body.appendChild(textArea); textArea.focus(); textArea.select(); try { var successful = document.execCommand('copy'); var msg = successful ? 'Results copied to clipboard!' : 'Copying failed!'; // Optional: Display a temporary message to the user var notification = document.createElement('div'); notification.textContent = msg; notification.style.cssText = 'position: fixed; top: 50%; left: 50%; transform: translate(-50%, -50%); background-color: #004a99; color: white; padding: 15px; border-radius: 5px; z-index: 1000;'; document.body.appendChild(notification); setTimeout(function() { document.body.removeChild(notification); }, 2000); } catch (err) { console.error('Fallback: Oops, unable to copy', err); // Display error message to user if copy fails var notification = document.createElement('div'); notification.textContent = 'Copying failed. Please copy manually.'; notification.style.cssText = 'position: fixed; top: 50%; left: 50%; transform: translate(-50%, -50%); background-color: #dc3545; color: white; padding: 15px; border-radius: 5px; z-index: 1000;'; document.body.appendChild(notification); setTimeout(function() { document.body.removeChild(notification); }, 2000); } document.body.removeChild(textArea); } // Initial calculation on page load document.addEventListener("DOMContentLoaded", function() { calculateACLoad(); // Perform initial calculation with default values });