Air Mass Flow Rate Calculator body { font-family: -apple-system, BlinkMacSystemFont, "Segoe UI", Roboto, Helvetica, Arial, sans-serif; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; background-color: #f4f7f6; } .calculator-container { background: #ffffff; padding: 30px; border-radius: 12px; box-shadow: 0 4px 6px rgba(0,0,0,0.1); margin-bottom: 40px; } .calculator-title { text-align: center; color: #2c3e50; margin-bottom: 25px; font-size: 24px; font-weight: 700; } .input-group { margin-bottom: 20px; } .input-group label { display: block; margin-bottom: 8px; font-weight: 600; color: #444; } .input-wrapper { display: flex; gap: 10px; } .form-control { flex: 2; padding: 12px; border: 1px solid #ddd; border-radius: 6px; font-size: 16px; transition: border-color 0.3s; } .form-select { flex: 1; padding: 12px; border: 1px solid #ddd; border-radius: 6px; background-color: #f8f9fa; font-size: 14px; } .form-control:focus, .form-select:focus { border-color: #3498db; outline: none; } .btn-calculate { width: 100%; padding: 15px; background-color: #3498db; color: white; border: none; border-radius: 6px; font-size: 18px; font-weight: bold; cursor: pointer; transition: background-color 0.2s; margin-top: 10px; } .btn-calculate:hover { background-color: #2980b9; } .result-box { margin-top: 30px; padding: 20px; background-color: #e8f6f3; border: 1px solid #c3e6cb; border-radius: 8px; display: none; } .result-title { color: #155724; font-weight: bold; margin-bottom: 15px; border-bottom: 1px solid #c3e6cb; padding-bottom: 10px; } .result-row { display: flex; justify-content: space-between; margin-bottom: 10px; font-size: 16px; } .result-value { font-weight: bold; color: #2c3e50; } .error-msg { color: #e74c3c; margin-top: 10px; display: none; font-weight: bold; text-align: center; } .info-icon { display: inline-block; width: 16px; height: 16px; background: #95a5a6; color: white; border-radius: 50%; text-align: center; line-height: 16px; font-size: 12px; margin-left: 5px; cursor: help; } /* Content Styles */ .content-section { background: #fff; padding: 30px; border-radius: 12px; box-shadow: 0 2px 4px rgba(0,0,0,0.05); } h2 { color: #2c3e50; border-bottom: 2px solid #3498db; padding-bottom: 10px; margin-top: 30px; } h3 { color: #34495e; margin-top: 25px; } p, li { color: #555; margin-bottom: 15px; } ul { padding-left: 20px; } .formula-box { background: #f8f9fa; padding: 15px; border-left: 4px solid #3498db; font-family: "Courier New", monospace; margin: 20px 0; overflow-x: auto; }

Air Mass Flow Rate Calculator

PSI Bar Pascal (Pa) Kilopascal (kPa)
Same as Upstream
Pressure after the orifice or restriction.
Celsius (°C) Fahrenheit (°F) Kelvin (K)
Millimeters (mm) Inches (in) Centimeters (cm)
Dimensionless
Calculation Results
Mass Flow Rate: – kg/s
Mass Flow Rate (Hourly): – kg/h
Standard Volumetric Flow: – SCFM
Air Density (Computed): – kg/m³
Pressure Drop: – Pa
Flow Condition:

Understanding Air Mass Flow Rate from Pressure

Calculating the mass flow rate of air based on pressure differential is a critical task in pneumatic engineering, HVAC system design, and fluid dynamics. This calculation determines how much air (in terms of mass) passes through a restriction, such as an orifice plate, nozzle, or valve, given a specific pressure drop.

The Physics of Air Flow

Air is a compressible fluid, meaning its density changes with pressure and temperature. When air flows through a restriction, potential energy (pressure) is converted into kinetic energy (velocity). The relationship between the pressure drop across the restriction and the flow rate is governed by Bernoulli's principle, adjusted for compressibility and friction losses via the Discharge Coefficient (Cd).

The Formula

For sub-sonic (unchoked) flow, this calculator uses the standard orifice flow equation derived from the ideal gas law and fluid mechanics principles:

ṁ = Cd × A × √ ( 2 × ρ × (P₁ – P₂) )

Where:

  • ṁ (m_dot): Mass flow rate (kg/s)
  • Cd: Discharge coefficient (typically ~0.61 for sharp-edged orifices)
  • A: Cross-sectional area of the orifice (m²)
  • ρ (rho): Density of air at upstream conditions (kg/m³)
  • P₁: Upstream absolute pressure (Pa)
  • P₂: Downstream absolute pressure (Pa)

Key Parameters Explained

  • Upstream Pressure (P₁): The absolute pressure of the air before it enters the restriction. Higher pressure generally increases density and flow potential.
  • Pressure Differential (ΔP): The difference between P₁ and P₂. This provides the driving force for the flow.
  • Temperature: Air temperature inversely affects density. Warmer air is less dense, which impacts the mass flow rate for a given volume.
  • Choked Flow: If the downstream pressure drops below approximately 52.8% of the upstream pressure (for air), the flow reaches the speed of sound (Mach 1). At this point, lowering the downstream pressure further does not increase the mass flow rate. This state is called "Choked Flow". This calculator detects this condition.

Common Applications

Engineers use these calculations for sizing pneumatic valves, calibrating flow meters, estimating leaks in compressed air systems, and designing engine intake manifolds.

function calculateAirFlow() { // Clear previous results/errors var errorBox = document.getElementById('errorBox'); var resultBox = document.getElementById('resultBox'); errorBox.style.display = 'none'; resultBox.style.display = 'none'; // 1. Get Inputs var p1Input = document.getElementById('upstreamPressure').value; var p2Input = document.getElementById('downstreamPressure').value; var tempInput = document.getElementById('airTemp').value; var diaInput = document.getElementById('orificeDiameter').value; var cdInput = document.getElementById('dischargeCoeff').value; // 2. Units var pUnit = document.getElementById('pressureUnit').value; var tUnit = document.getElementById('tempUnit').value; var dUnit = document.getElementById('diameterUnit').value; // 3. Validation if (p1Input === "" || p2Input === "" || tempInput === "" || diaInput === "" || cdInput === "") { errorBox.innerText = "Please fill in all fields."; errorBox.style.display = 'block'; return; } var p1 = parseFloat(p1Input); var p2 = parseFloat(p2Input); var t = parseFloat(tempInput); var d = parseFloat(diaInput); var cd = parseFloat(cdInput); if (isNaN(p1) || isNaN(p2) || isNaN(t) || isNaN(d) || isNaN(cd)) { errorBox.innerText = "Please enter valid numbers."; errorBox.style.display = 'block'; return; } if (d <= 0 || cd <= 0 || p1 = p1_pa) { errorBox.innerText = "Upstream pressure (P1) must be greater than Downstream pressure (P2)."; errorBox.style.display = 'block'; return; } // Temperature to Kelvin var t_k = 0; if (tUnit === "c") { t_k = t + 273.15; } else if (tUnit === "f") { t_k = (t – 32) * 5/9 + 273.15; } else { t_k = t; } // Diameter to Meters var d_m = 0; if (dUnit === "mm") { d_m = d / 1000; } else if (dUnit === "in") { d_m = d * 0.0254; } else if (dUnit === "cm") { d_m = d / 100; } // 5. Physics Constants var R_air = 287.05; // Specific gas constant for dry air J/(kg·K) var k_air = 1.4; // Heat capacity ratio (adiabatic index) // 6. Calculation Logic // Calculate Density at Upstream (Ideal Gas Law: rho = P / RT) var rho = p1_pa / (R_air * t_k); // Calculate Orifice Area (A = pi * r^2) var area = Math.PI * Math.pow((d_m / 2), 2); // Check for Choked Flow // Critical pressure ratio for air = (2/(k+1))^(k/(k-1)) ≈ 0.528 var criticalRatio = 0.528; var actualRatio = p2_pa / p1_pa; var isChoked = actualRatio 0 // Simplified Y ≈ 1 – (1/k) * (dP/P1) * (some factor). // For this simpler tool, we stick to the widely used hydraulic approximation: // m = Cd * A * sqrt(2 * rho * dP) // Note: This overestimates slightly as dP increases, but is standard for basic tools. var dP = p1_pa – p2_pa; massFlow = cd * area * Math.sqrt(2 * rho * dP); } // 7. Result Conversions var massFlowKgHr = massFlow * 3600; // SCFM Calculation // Standard conditions: 1 atm (101325 Pa), 20°C (293.15 K) -> Density_std approx 1.204 kg/m3 // Sometimes SCFM uses 15C or 0C. Let's use 20C/1atm (NIST normal). var rho_std = 1.2041; var volFlowStd_m3s = massFlow / rho_std; var scfm = volFlowStd_m3s * 2118.88; // m3/s to cfm // 8. Display Results document.getElementById('resKgS').innerText = massFlow.toFixed(4) + " kg/s"; document.getElementById('resKgHr').innerText = massFlowKgHr.toFixed(2) + " kg/h"; document.getElementById('resSCFM').innerText = scfm.toFixed(2) + " SCFM"; document.getElementById('resDensity').innerText = rho.toFixed(3) + " kg/m³"; document.getElementById('resDrop').innerText = (p1_pa – p2_pa).toFixed(0) + " Pa"; document.getElementById('resCondition').innerText = flowConditionText; resultBox.style.display = 'block'; }