Calculating Effective Seismic Weight

Effective Seismic Weight Calculator & Guide :root { –primary-color: #004a99; –success-color: #28a745; –background-color: #f8f9fa; –text-color: #333; –border-color: #ccc; –card-background: #fff; –error-color: #dc3545; } body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; background-color: var(–background-color); color: var(–text-color); line-height: 1.6; margin: 0; padding: 0; } .container { max-width: 1000px; margin: 20px auto; padding: 20px; background-color: var(–card-background); box-shadow: 0 2px 10px rgba(0, 0, 0, 0.1); border-radius: 8px; } header { text-align: center; margin-bottom: 30px; border-bottom: 2px solid var(–primary-color); padding-bottom: 20px; } h1, h2, h3 { color: var(–primary-color); } h1 { font-size: 2.5em; margin-bottom: 10px; } h2 { font-size: 1.8em; margin-top: 30px; margin-bottom: 15px; } h3 { font-size: 1.4em; margin-top: 25px; margin-bottom: 10px; } .sub-heading { font-size: 1.1em; color: #555; margin-bottom: 20px; } .loan-calc-container { background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: inset 0 1px 5px rgba(0,0,0,0.05); margin-bottom: 30px; } .input-group { margin-bottom: 20px; text-align: left; } .input-group label { display: block; margin-bottom: 8px; font-weight: bold; color: #444; } .input-group input[type="number"], .input-group select { width: calc(100% – 22px); /* Adjust for padding and border */ padding: 10px; border: 1px solid var(–border-color); border-radius: 5px; font-size: 1em; box-sizing: border-box; } .input-group input[type="number"]:focus, .input-group select:focus { outline: none; border-color: var(–primary-color); box-shadow: 0 0 0 2px rgba(0, 74, 153, 0.2); } .input-group small { display: block; margin-top: 5px; color: #6c757d; font-size: 0.9em; } .error-message { color: var(–error-color); font-size: 0.9em; margin-top: 5px; height: 1.2em; /* Reserve space to prevent layout shifts */ } .button-group { display: flex; justify-content: space-between; margin-top: 25px; gap: 10px; } .btn { padding: 12px 20px; border: none; border-radius: 5px; cursor: pointer; font-size: 1em; font-weight: bold; transition: background-color 0.3s ease, transform 0.2s ease; text-decoration: none; display: inline-block; text-align: center; } .btn-primary { background-color: var(–primary-color); color: white; } .btn-primary:hover { background-color: #003366; transform: translateY(-2px); } .btn-secondary { background-color: #6c757d; color: white; } .btn-secondary:hover { background-color: #5a6268; transform: translateY(-2px); } .btn-reset { background-color: #ffc107; color: #212529; } .btn-reset:hover { background-color: #e0a800; transform: translateY(-2px); } #results { margin-top: 30px; padding: 25px; background-color: var(–primary-color); color: white; border-radius: 8px; text-align: center; box-shadow: inset 0 3px 8px rgba(0,0,0,0.2); } #results h3 { color: white; margin-top: 0; margin-bottom: 15px; } #results .main-result { font-size: 2.5em; font-weight: bold; margin-bottom: 15px; padding: 10px; background-color: rgba(255, 255, 255, 0.2); border-radius: 5px; } #results .intermediate-values { font-size: 1.2em; margin-bottom: 20px; display: flex; flex-wrap: wrap; justify-content: center; gap: 20px; } #results .intermediate-values div { text-align: center; } #results .intermediate-values span { font-weight: bold; display: block; font-size: 1.5em; } #results .formula-explanation { font-size: 0.95em; font-style: italic; color: rgba(255, 255, 255, 0.8); margin-top: 15px; border-top: 1px solid rgba(255, 255, 255, 0.3); padding-top: 15px; } table { width: 100%; margin-top: 30px; border-collapse: collapse; border-radius: 8px; overflow: hidden; /* Ensures rounded corners apply to cells */ } thead { background-color: var(–primary-color); color: white; } th, td { padding: 12px 15px; text-align: left; border: 1px solid var(–border-color); } tbody tr:nth-child(even) { background-color: #e9ecef; } tbody tr:hover { background-color: #dee2e6; } caption { font-size: 1.1em; font-weight: bold; margin-bottom: 15px; color: #333; caption-side: top; /* Standard for tables */ text-align: left; } canvas { display: block; margin: 30px auto; background-color: var(–card-background); border: 1px solid var(–border-color); border-radius: 5px; max-width: 100%; height: auto; /* Maintain aspect ratio */ } .article-content { margin-top: 40px; background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: inset 0 1px 5px rgba(0,0,0,0.05); } .article-content p, .article-content ul, .article-content ol { margin-bottom: 20px; color: #444; } .article-content ul, .article-content ol { padding-left: 25px; } .article-content li { margin-bottom: 10px; } .article-content strong { color: var(–primary-color); } .faq-section .faq-item { margin-bottom: 15px; border-left: 4px solid var(–primary-color); padding-left: 15px; background-color: #f1f1f1; border-radius: 0 5px 5px 0; } .faq-section .faq-item h4 { margin-bottom: 5px; cursor: pointer; font-size: 1.2em; color: var(–primary-color); } .faq-section .faq-item p { margin-top: 5px; display: none; /* Initially hidden */ color: #555; } .faq-section .faq-item.open p { display: block; } .related-links ul { list-style: none; padding: 0; } .related-links li { margin-bottom: 15px; } .related-links a { color: var(–primary-color); text-decoration: none; font-weight: bold; } .related-links a:hover { text-decoration: underline; } .related-links span { display: block; font-size: 0.9em; color: #555; margin-top: 3px; } footer { text-align: center; margin-top: 40px; padding-top: 20px; border-top: 1px solid var(–border-color); font-size: 0.9em; color: #6c757d; } /* Specific styles for seismic weight calculator */ .input-group label[for="floorArea"], .input-group label[for="floorHeight"], .input-group label[for="concreteDensity"], .input-group label[for="deadLoadFactor"], .input-group label[for="liveLoadFactor"], .input-group label[for="occupancyLoad"], .input-group label[for="partitionLoad"] { color: #004a99; } .input-group small { color: #555; } #results .main-result-label { font-size: 1.3em; font-weight: normal; color: white; display: block; margin-bottom: 10px; } #chart-legend { text-align: center; margin-top: 15px; font-size: 0.9em; color: #555; } #chart-legend span { display: inline-block; margin: 0 10px; } #chart-legend .legend-item { display: inline-flex; align-items: center; margin: 0 10px; } #chart-legend .legend-color-box { display: inline-block; width: 15px; height: 15px; margin-right: 5px; border: 1px solid #ccc; } .legend-color-box.total-load { background-color: #004a99; } .legend-color-box.seismic-load { background-color: #28a745; }

Effective Seismic Weight Calculator

Accurately calculate the seismic weight of your structure for earthquake-resistant design.

Seismic Weight Calculation Inputs

Enter the total area of one typical floor in square meters (m²).
Enter the clear height of one floor in meters (m).
Enter the total number of stories in the building.
Typical density of reinforced concrete in kg/m³ (e.g., 2400 kg/m³).
Factor for permanent structural loads (e.g., 1.2 kN/m² for slabs).
Factor for variable non-structural loads (e.g., 2.0 kN/m² for typical occupancy).
Additional load for specific occupancies (e.g., 1.5 kN/m² for library).
Estimated load from interior partitions in kN/m² (e.g., 1.0 kN/m²).

Seismic Weight Calculation Results

0 kN
Effective Seismic Weight
Total Dead Load Per Floor 0 kN/m²
Total Live Load Per Floor 0 kN/m²
Total Weight Per Floor 0 kN
Effective Seismic Weight = Sum of (Total Dead Load + Seismic Live Load + Partition Load) for each floor, applied at each floor's center of mass. This calculation uses a simplified approach considering typical loads. For detailed seismic design, consult relevant building codes and structural engineers.

Seismic Weight Distribution

Total Load per Floor Seismic Weight per Floor
Seismic Weight Calculation Breakdown by Floor
Floor Area (m²) Total Dead Load (kN/m²) Seismic Live Load (kN/m²) Partition Load (kN/m²) Total Load Per Floor (kN/m²) Total Weight Per Floor (kN)

What is Effective Seismic Weight?

Effective seismic weight is a crucial concept in structural engineering, particularly for designing buildings and structures in earthquake-prone regions. It represents the portion of the total building weight that is considered active during seismic events and contributes to the inertial forces generated by ground motion. Essentially, it's the weight that "pushes" against the structure when the ground shakes. It's not simply the total dead weight of the building; rather, it's a carefully calculated value that accounts for how different loads are distributed and their behavior under dynamic seismic loading.

Who should use it? This calculation is primarily used by structural engineers, architects, seismic retrofit specialists, and building code officials involved in the design and assessment of structures for earthquake resistance. Homeowners or building managers might use a calculator like this to gain a basic understanding of seismic design principles or to discuss design parameters with their engineers.

Common misconceptions about effective seismic weight include assuming it's the same as the total dead load, or that all live load contributes equally to seismic forces. In reality, building codes often specify factors for reducing the live load considered for seismic calculations, as it's less likely for a building to be at its maximum live load capacity during a significant earthquake. Furthermore, the distribution of weight and the stiffness of the structure significantly influence the effective seismic weight and its impact.

Effective Seismic Weight Formula and Mathematical Explanation

The calculation of effective seismic weight can vary based on the specific building code and the complexity of the structure. A simplified approach, often used for preliminary estimations, involves summing the dead loads and a fraction of the live loads at each floor level. The effective seismic weight of a building is the summation of the seismic weight of each floor.

Formula Derivation:

For each floor, the total load is a combination of dead loads (structural elements, finishes) and live loads (occupants, furniture, equipment). For seismic calculations, building codes typically require considering a significant portion of the dead load and a reduced, or seismic-specific, portion of the live load.

1. Calculate Total Load per Square Meter for a Floor (L_floor):

L_floor = (DL_factor * Unit_DL) + (LL_factor * Unit_LL) + Partition_Load + Occupancy_Load

Where:

  • DL_factor: Factor applied to the unit dead load (often related to material density and slab thickness).
  • Unit_DL: Unit dead load of the floor structure (e.g., kN/m²).
  • LL_factor: Factor applied to the unit live load (usually stipulated by codes for seismic considerations).
  • Unit_LL: Unit live load based on building use (e.g., kN/m²).
  • Partition_Load: Additional load from non-structural partitions (kN/m²).
  • Occupancy_Load: Specific load due to intended occupancy (e.g., kN/m² for libraries, archives).

2. Calculate Total Weight of a Floor (W_floor):

W_floor = L_floor * Floor_Area

Where:

  • Floor_Area: The total area of the floor in m².

3. Determine Seismic Live Load Contribution:

Building codes often specify a percentage of the specified live load to be considered for seismic design. For simplicity in this calculator, we'll use a common approach where a portion of the live load is considered. The calculator's "Live Load Factor" and "Occupancy Load" implicitly handle this for estimation.

4. Calculate Effective Seismic Weight for the Building (W_seismic_total):

W_seismic_total = Σ (W_floor_i) for all floors i.

This summation represents the total effective seismic weight of the structure.

Variables Table:

Seismic Weight Calculation Variables
Variable Meaning Unit Typical Range / Notes
Floor Area Area of a single floor e.g., 200 – 2000 m²
Floor Height Vertical distance between floors m e.g., 2.5 – 4.0 m
Number of Floors Total stories in the building e.g., 1 – 50
Concrete Density Mass per unit volume of concrete kg/m³ 1500 – 2500 kg/m³ (Lightweight to Normal Weight)
Dead Load Factor Coefficient for permanent structural loads kN/m² Often derived from material properties (e.g., 1.0 – 2.0)
Live Load Factor Coefficient for variable non-structural loads (seismic consideration) kN/m² Codes specify, often lower than static load factors (e.g., 0.5 – 1.5)
Occupancy Load Additional load due to specific building use kN/m² e.g., 0.5 – 5.0 kN/m² (Residential, Commercial, Storage)
Partition Load Load from non-structural interior walls kN/m² e.g., 0.5 – 1.5 kN/m²
Total Dead Load Per Floor Sum of permanent loads per floor area kN/m² Calculated value
Total Live Load Per Floor Sum of variable loads per floor area (incl. seismic factors) kN/m² Calculated value
Total Weight Per Floor Total load on a floor multiplied by its area kN Calculated value
Effective Seismic Weight Total weight contributing to seismic inertial forces kN Calculated value

Practical Examples (Real-World Use Cases)

Example 1: Mid-Rise Office Building Floor

Consider a typical floor in a 5-story office building:

  • Floor Area: 800 m²
  • Floor Height: 3.2 m
  • Number of Floors: 5
  • Concrete Density: 2400 kg/m³ (weight ≈ 24 kN/m³)
  • Dead Load Factor: 1.2 (for self-weight of slab, finishes)
  • Live Load Factor (Seismic): 1.0 (typical office occupancy, code-based reduction)
  • Occupancy Load: 0 kN/m² (standard office doesn't need extra)
  • Partition Load: 1.0 kN/m² (for interior walls)

Calculation Steps:

  1. Unit Dead Load (DL): Assume slab thickness and finishes result in approx. 10 kN/m² (DL_factor * avg_concrete_density_converted).
  2. Unit Live Load (LL): Standard office live load is typically 2.0 kN/m².
  3. Total Dead Load Per Floor: 1.2 * 10 kN/m² = 12 kN/m²
  4. Total Live Load Per Floor (Seismic): 1.0 * 2.0 kN/m² = 2.0 kN/m²
  5. Total Load Per Floor (kN/m²): 12 kN/m² (Dead) + 2.0 kN/m² (Live) + 1.0 kN/m² (Partition) = 15 kN/m²
  6. Total Weight Per Floor: 15 kN/m² * 800 m² = 12,000 kN

Result Interpretation: This single floor contributes 12,000 kN to the building's total seismic weight. If all floors are similar, the total seismic weight would be 12,000 kN/floor * 5 floors = 60,000 kN.

Example 2: Residential Building Floor with Storage Area

Consider a floor in a 3-story residential building with a dedicated storage area:

  • Floor Area: 400 m²
  • Floor Height: 3.0 m
  • Number of Floors: 3
  • Concrete Density: 2300 kg/m³ (weight ≈ 23 kN/m³)
  • Dead Load Factor: 1.1
  • Live Load Factor (Seismic): 0.7 (residential code factor)
  • Occupancy Load: 1.0 kN/m² (for storage area portion)
  • Partition Load: 0.8 kN/m²

Calculation Steps:

  1. Unit Dead Load (DL): Assume slab and finishes contribute 9 kN/m².
  2. Unit Live Load (LL): Standard residential live load is 1.5 kN/m².
  3. Total Dead Load Per Floor: 1.1 * 9 kN/m² = 9.9 kN/m²
  4. Seismic Live Load (Residential): 0.7 * 1.5 kN/m² = 1.05 kN/m²
  5. Total Load Per Floor (kN/m²): 9.9 kN/m² (Dead) + 1.05 kN/m² (Live) + 0.8 kN/m² (Partition) + 1.0 kN/m² (Storage) = 12.75 kN/m²
  6. Total Weight Per Floor: 12.75 kN/m² * 400 m² = 5,100 kN

Result Interpretation: Each floor of this residential building weighs approximately 5,100 kN under seismic consideration. The total seismic weight for the structure is 5,100 kN/floor * 3 floors = 15,300 kN.

How to Use This Effective Seismic Weight Calculator

Using our calculator is straightforward and designed to provide quick estimates for structural analysis.

  1. Enter Floor Area: Input the total square meter area of a typical floor.
  2. Enter Floor Height: Provide the vertical distance between floors in meters.
  3. Enter Number of Floors: Specify the total number of stories in the building.
  4. Input Material Properties: Enter the concrete density (kg/m³) and relevant load factors. Default values are provided for common scenarios.
  5. Add Additional Loads: Include estimated values for partition walls and specific occupancy loads if applicable.
  6. Calculate: Click the "Calculate Seismic Weight" button.

How to Read Results:

  • Effective Seismic Weight (Main Result): This is the total calculated seismic weight of the entire structure in kilonewtons (kN).
  • Intermediate Values: These show the calculated total dead load, seismic live load, and total weight for a single typical floor.
  • Table Breakdown: The table provides a detailed view of the calculation for each floor, allowing you to see how the total weight is distributed.
  • Chart: Visualizes the distribution of total load versus seismic weight across the floors.

Decision-Making Guidance: The calculated effective seismic weight is a primary input for determining seismic design forces according to building codes. A higher effective seismic weight generally leads to higher required seismic resistance. This calculation helps engineers understand the seismic mass of the structure, informing decisions on structural system selection, member sizing, and seismic detailing. Always consult the relevant local building codes (e.g., IBC, Eurocode) and a qualified structural engineer for actual design purposes.

Key Factors That Affect Effective Seismic Weight Results

Several factors significantly influence the calculated effective seismic weight of a structure:

  1. Building Geometry and Size: Larger floor areas and taller buildings naturally have greater weight, thus increasing the seismic mass. The number of floors directly impacts the total summation.
  2. Material Properties: The density of construction materials is fundamental. Heavier materials like dense concrete or steel result in a higher seismic weight compared to lighter materials like timber or lightweight concrete.
  3. Dead Loads: These are permanent structural elements (slabs, beams, columns, walls) and non-structural elements (cladding, finishes, fixed equipment). Higher dead loads directly increase seismic weight.
  4. Live Loads: While codes often reduce the stipulated live load for seismic calculations, the intended use of the space is critical. Areas designated for heavy storage, equipment, or high occupancy will contribute more to the seismic weight than standard residential or office spaces.
  5. Partition and Finishes: The type and density of interior partition walls, ceiling systems, and floor finishes add to the overall dead load and must be accounted for. Heavy masonry partitions, for example, significantly increase seismic mass.
  6. Irregularities and Mass Distribution: Unusual building shapes, significant setbacks, or heavy equipment concentrated on specific floors can create torsional effects and alter the distribution of seismic forces. While this calculator uses a simplified floor-by-floor approach, actual seismic analysis considers these complexities.
  7. Code Provisions: Building codes dictate how live loads are reduced, what minimum loads are applied, and specific factors for different occupancies. Adherence to these codes ensures a standardized and safe approach.
  8. Foundation Type and Soil Conditions: While not directly part of the seismic weight calculation itself, foundation behavior and soil-site interaction can amplify or mitigate seismic effects, indirectly influencing the overall seismic performance design which relies on accurate seismic weight.

Frequently Asked Questions (FAQ)

Q1: Is the Effective Seismic Weight the same as the Total Building Weight?

A1: No. The effective seismic weight is the portion of the total building weight that is considered to exert inertial forces during an earthquake. It often involves applying specific factors (especially for live loads) as dictated by seismic design codes, and may exclude certain non-contributing weights.

Q2: Why do building codes reduce the live load for seismic calculations?

A2: It's highly improbable that a building will be at its maximum design live load capacity during a major earthquake. Codes use reduced live load factors to reflect this statistical reality and prevent over-designing for rarely occurring combined load scenarios, focusing on the more consistent dead loads and a representative portion of live loads.

Q3: What is the difference between Dead Load and Live Load in seismic terms?

A3: Dead Load includes the permanent weight of structural components, finishes, and permanently attached fixtures. Live Load includes temporary or variable loads like occupants, furniture, and movable equipment. For seismic calculations, dead loads are typically fully considered, while live loads are adjusted by code-specified factors.

Q4: How does the number of floors affect the seismic weight?

A4: The effective seismic weight is cumulative. Each additional floor increases the total weight of the structure, and therefore increases the total seismic weight that must be resisted by the structure's lateral force-resisting system.

Q5: Can heavy partitions increase seismic risk?

A5: Yes. Heavy partition walls add significantly to the dead load and thus the seismic weight. If these partitions are not adequately braced or isolated from the main structure, they can also behave dynamically and potentially impact structural integrity or pose a falling hazard during an earthquake.

Q6: Does this calculator account for the seismic force itself (e.g., acceleration)?

A6: No. This calculator determines the effective seismic weight, which is a component used to calculate seismic forces. The actual seismic force is determined by multiplying this weight by seismic coefficients (related to seismic zone, soil type, building importance, and structural response characteristics), as defined by engineering codes.

Q7: What is the role of floor height in seismic weight calculation?

A7: Floor height itself doesn't directly factor into the weight calculation per se, but it influences the overall building height and volume. In dynamic analysis, the distribution of seismic forces along the height of the building is crucial, and the floor height contributes to the height of the center of mass for each floor.

Q8: Can I use these results for actual building design?

A8: This calculator provides an estimate for educational and preliminary purposes. Actual building design requires detailed analysis by a licensed structural engineer, considering specific local building codes, site-specific seismic hazard analysis, and complex structural behaviors not captured in simplified calculators.

© 2023 Your Company Name. All rights reserved.

function isValidNumber(value, min = -Infinity, max = Infinity) { if (value === null || value === "") return false; var num = parseFloat(value); return !isNaN(num) && num >= min && num = 1 m²)."; errors = true; } if (!isValidNumber(floorHeight, 1)) { document.getElementById("floorHeightError").textContent = "Please enter a valid floor height (>= 1 m)."; errors = true; } if (!isValidNumber(numberOfFloors, 1, 100)) { document.getElementById("numberOfFloorsError").textContent = "Please enter a valid number of floors (1-100)."; errors = true; } if (!isValidNumber(concreteDensity, 1000, 3000)) { document.getElementById("concreteDensityError").textContent = "Please enter a valid concrete density (1000-3000 kg/m³)."; errors = true; } if (!isValidNumber(deadLoadFactor, 0.1, 10)) { document.getElementById("deadLoadFactorError").textContent = "Please enter a valid dead load factor (0.1-10)."; errors = true; } if (!isValidNumber(liveLoadFactor, 0.1, 10)) { document.getElementById("liveLoadFactorError").textContent = "Please enter a valid live load factor (0.1-10)."; errors = true; } if (!isValidNumber(occupancyLoad, 0, 10)) { document.getElementById("occupancyLoadError").textContent = "Please enter a valid occupancy load (0-10 kN/m²)."; errors = true; } if (!isValidNumber(partitionLoad, 0, 5)) { document.getElementById("partitionLoadError").textContent = "Please enter a valid partition load (0-5 kN/m²)."; errors = true; } if (errors) { document.getElementById("results").style.display = "none"; document.getElementById("chartContainer").style.display = "none"; return; } var totalSeismicWeight = 0; var tbody = document.getElementById("tbody-seismic-breakdown"); tbody.innerHTML = ""; // Clear previous table rows // Approximate Unit Dead Load from concrete density (assuming standard slab thickness and finishes) // This is a simplification. A more accurate calculation would involve slab thickness and material weights. // For this calculator, let's assume a base dead load component from materials. // Example: Concrete weight is approx 24 kN/m³. Let's use this as a base. var unitDeadLoadFromConcrete = concreteDensity / 1000 * 9.81; // Convert kg/m³ to kN/m³ (approx 23.55 kN/m³ for 2400 kg/m³) // Add a component for finishes, ceiling etc. Let's assume 1-2 kN/m² extra. var additionalFinishesLoad = 1.5; // kN/m² var totalSeismicWeightValues = []; var totalLoadPerFloorValues = []; for (var i = 1; i index % 2 === 0)); // Pass floor weights } function updateChart(numFloors, totalLoadsPerSqMeter, floorWeights) { var ctx = document.getElementById("seismicWeightChart").getContext("2d"); var labels = []; for(var i = 1; i weight.toFixed(2)); var totalLoadsPerFloorSqMeter = totalLoadsPerSqMeter.map(load => load.toFixed(2)); // Destroy previous chart instance if it exists var existingChart = Chart.getChart("seismicWeightChart"); if (existingChart) { existingChart.destroy(); } new Chart(ctx, { type: 'bar', data: { labels: labels, datasets: [{ label: 'Total Load per Floor (kN)', data: totalWeightsPerFloor, // Represents total weight per floor backgroundColor: 'rgba(0, 74, 153, 0.6)', // Primary color borderColor: 'rgba(0, 74, 153, 1)', borderWidth: 1 }, { label: 'Seismic Weight per Floor (kN)', data: floorWeights, // Represents calculated seismic weight per floor backgroundColor: 'rgba(40, 167, 69, 0.6)', // Success color borderColor: 'rgba(40, 167, 69, 1)', borderWidth: 1 }] }, options: { responsive: true, maintainAspectRatio: false, scales: { y: { beginAtZero: true, title: { display: true, text: 'Weight (kN)' } }, x: { title: { display: true, text: 'Floor Level' } } }, plugins: { legend: { display: false // Using custom legend }, tooltip: { callbacks: { label: function(context) { var label = context.dataset.label || "; if (label) { label += ': '; } if (context.parsed.y !== null) { label += context.parsed.y + ' kN'; } return label; } } } } } }); } function copyResults() { var mainResult = document.getElementById("effectiveSeismicWeight").textContent; var intermediateValues = document.getElementsByClassName("intermediate-values")[0].innerText.replace(/kN\//g, 'kN / ').replace(/kN$/, 'kN'); var assumptions = "Key Assumptions:\n"; assumptions += "- Floor Area: " + document.getElementById("floorArea").value + " m²\n"; assumptions += "- Floor Height: " + document.getElementById("floorHeight").value + " m\n"; assumptions += "- Number of Floors: " + document.getElementById("numberOfFloors").value + "\n"; assumptions += "- Concrete Density: " + document.getElementById("concreteDensity").value + " kg/m³\n"; assumptions += "- Dead Load Factor: " + document.getElementById("deadLoadFactor").value + "\n"; assumptions += "- Live Load Factor: " + document.getElementById("liveLoadFactor").value + "\n"; assumptions += "- Occupancy Load: " + document.getElementById("occupancyLoad").value + " kN/m²\n"; assumptions += "- Partition Load: " + document.getElementById("partitionLoad").value + " kN/m²\n"; var table = document.getElementById("tbody-seismic-breakdown"); var tableRows = table.rows; var tableData = "Floor Breakdown:\n"; tableData += "Floor\tArea (m²)\tDead Load (kN/m²)\tLive Load (kN/m²)\tPartition Load (kN/m²)\tTotal Load/m² (kN/m²)\tTotal Weight/Floor (kN)\n"; for (var i = 0; i < tableRows.length; i++) { for (var j = 0; j < tableRows[i].cells.length; j++) { tableData += tableRows[i].cells[j].textContent + "\t"; } tableData += "\n"; } var resultText = "Effective Seismic Weight Calculator Results:\n\n"; resultText += "Effective Seismic Weight: " + mainResult + " kN\n\n"; resultText += "Key Floor Values:\n" + intermediateValues + "\n\n"; resultText += assumptions + "\n\n"; resultText += tableData; navigator.clipboard.writeText(resultText).then(function() { alert("Results copied to clipboard!"); }).catch(function(err) { console.error("Failed to copy results: ", err); alert("Failed to copy results. Please copy manually."); }); } function resetForm() { document.getElementById("floorArea").value = ""; document.getElementById("floorHeight").value = ""; document.getElementById("numberOfFloors").value = ""; document.getElementById("concreteDensity").value = "2400"; document.getElementById("deadLoadFactor").value = "1.2"; document.getElementById("liveLoadFactor").value = "2.0"; document.getElementById("occupancyLoad").value = ""; document.getElementById("partitionLoad").value = ""; clearErrorMessages(); document.getElementById("results").style.display = "none"; document.getElementById("chartContainer").style.display = "none"; document.getElementById("tbody-seismic-breakdown").innerHTML = ""; // Clear table } // Initialize Tooltip behavior for Faqs var faqItems = document.querySelectorAll('.faq-item h4'); for (var i = 0; i < faqItems.length; i++) { faqItems[i].addEventListener('click', function() { var parent = this.parentElement; parent.classList.toggle('open'); }); }

Leave a Comment