Calculating Molecular Weight from Size Exclusion Chromatography

Size Exclusion Chromatography Molecular Weight Calculator :root { –primary-color: #004a99; –success-color: #28a745; –background-color: #f8f9fa; –text-color: #333; –border-color: #ddd; –card-background: #fff; –shadow-color: rgba(0, 0, 0, 0.1); } body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; line-height: 1.6; background-color: var(–background-color); color: var(–text-color); margin: 0; padding: 0; display: flex; justify-content: center; padding-top: 20px; padding-bottom: 40px; } .container { width: 95%; max-width: 960px; background-color: var(–card-background); padding: 30px; border-radius: 10px; box-shadow: 0 4px 15px var(–shadow-color); display: flex; flex-direction: column; gap: 30px; } header { text-align: center; margin-bottom: 20px; } header h1 { color: var(–primary-color); font-size: 2.5em; margin-bottom: 10px; } header p { font-size: 1.1em; color: #555; } .calculator-section { background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: 0 2px 10px var(–shadow-color); } .calculator-section h2 { color: var(–primary-color); margin-top: 0; margin-bottom: 20px; text-align: center; font-size: 2em; } .input-group { margin-bottom: 20px; width: 100%; } .input-group label { display: block; margin-bottom: 8px; font-weight: bold; color: var(–primary-color); } .input-group input[type="number"], .input-group input[type="text"], .input-group select { width: calc(100% – 22px); padding: 12px 10px; border: 1px solid var(–border-color); border-radius: 5px; font-size: 1em; margin-bottom: 5px; box-sizing: border-box; } .input-group .helper-text { font-size: 0.85em; color: #666; display: block; margin-top: 5px; } .error-message { color: #dc3545; font-size: 0.85em; margin-top: 5px; display: none; /* Hidden by default */ } .button-group { display: flex; gap: 10px; margin-top: 25px; justify-content: center; } button { padding: 12px 25px; border: none; border-radius: 5px; cursor: pointer; font-size: 1em; font-weight: bold; transition: background-color 0.3s ease; } button.primary { background-color: var(–primary-color); color: white; } button.primary:hover { background-color: #003366; } button.secondary { background-color: #6c757d; color: white; } button.secondary:hover { background-color: #5a6268; } button.success { background-color: var(–success-color); color: white; } button.success:hover { background-color: #218838; } #results { margin-top: 30px; padding: 25px; background-color: var(–primary-color); color: white; border-radius: 8px; text-align: center; box-shadow: inset 0 0 10px rgba(0,0,0,0.2); } #results .main-result { font-size: 2.5em; font-weight: bold; margin-bottom: 15px; display: inline-block; padding: 10px 20px; background-color: rgba(255, 255, 255, 0.2); border-radius: 5px; } #results .formula-explanation { font-size: 0.9em; margin-top: 15px; opacity: 0.8; } #results .intermediate-results div, #results .key-assumptions div { margin-top: 10px; font-size: 1.1em; opacity: 0.9; } #results .intermediate-results span, #results .key-assumptions span { font-weight: bold; } #results .intermediate-results { margin-top: 20px; border-top: 1px solid rgba(255, 255, 255, 0.3); padding-top: 15px; } #results .key-assumptions { margin-top: 15px; border-top: 1px solid rgba(255, 255, 255, 0.3); padding-top: 15px; font-size: 0.95em; opacity: 0.8; } table { width: 100%; border-collapse: collapse; margin-top: 20px; box-shadow: 0 2px 5px var(–shadow-color); } th, td { padding: 12px; text-align: left; border-bottom: 1px solid var(–border-color); } thead th { background-color: var(–primary-color); color: white; font-weight: bold; } tbody tr:nth-child(even) { background-color: #f2f2f2; } caption { caption-side: top; font-weight: bold; font-size: 1.1em; color: var(–primary-color); margin-bottom: 10px; text-align: left; } .chart-container { text-align: center; margin-top: 30px; background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: 0 2px 10px var(–shadow-color); } .chart-container h3 { color: var(–primary-color); margin-top: 0; font-size: 1.8em; margin-bottom: 20px; } canvas { max-width: 100%; height: auto; display: block; margin: 0 auto; border: 1px solid var(–border-color); border-radius: 5px; } .article-section { background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: 0 2px 10px var(–shadow-color); margin-top: 30px; } .article-section h2, .article-section h3 { color: var(–primary-color); margin-top: 0; margin-bottom: 15px; } .article-section h2 { font-size: 2.2em; text-align: center; } .article-section h3 { font-size: 1.6em; border-bottom: 2px solid var(–primary-color); padding-bottom: 5px; } .article-section p { margin-bottom: 15px; } .article-section ul, .article-section ol { margin-left: 20px; margin-bottom: 15px; } .article-section li { margin-bottom: 8px; } .internal-links-list { list-style: none; padding: 0; margin-top: 20px; } .internal-links-list li { margin-bottom: 15px; padding-bottom: 10px; border-bottom: 1px dashed var(–border-color); } .internal-links-list li:last-child { border-bottom: none; margin-bottom: 0; } .internal-links-list a { color: var(–primary-color); text-decoration: none; font-weight: bold; } .internal-links-list a:hover { text-decoration: underline; } .internal-links-list span { display: block; font-size: 0.9em; color: #666; margin-top: 5px; } .text-highlight { background-color: var(–primary-color); color: white; padding: 2px 5px; border-radius: 3px; } .key-factor { font-weight: bold; color: var(–primary-color); }

Size Exclusion Chromatography Molecular Weight Calculator

Determine polymer molecular weight distributions from SEC data accurately and efficiently.

SEC Molecular Weight Calculator

Enter the measured retention time of your sample in minutes.
Enter the void volume of the SEC column in mL.
Enter the exclusion limit volume in mL.
Enter the total permeation volume in mL.
Format: K_av, log10(MW). Kav = (Ko – tR) / (Vt – V0) or similar normalization.
Calculated using the relationship derived from the calibration curve: log10(MW) = m * log10(Kav) + c, where MW is Molecular Weight and Kav is the partition coefficient.
Kav:
log10(MW):
Calculated MW:
Key Assumptions:
Calibration curve is linear in the relevant Kav range.
Sample behaves ideally in SEC (e.g., no association/adsorption).
Kav calculation uses appropriate normalization.

Calibration Curve and Sample Point

Calibration curve based on provided standards, with sample point highlighted.

What is Size Exclusion Chromatography (SEC) Molecular Weight Determination?

Size Exclusion Chromatography (SEC), also known as Gel Permeation Chromatography (GPC), is a powerful liquid chromatography technique used to separate molecules based on their hydrodynamic volume or size in solution. When applied to polymers, this separation allows for the determination of their molecular weight and molecular weight distribution (MWD). The fundamental principle of SEC for calculating molecular weight relies on the fact that larger molecules elute from the column earlier than smaller ones because they are excluded from the pores of the stationary phase. This characteristic separation behavior forms the basis for constructing calibration curves using known standards, which are then used to predict the molecular weights of unknown samples based on their elution times.

Who should use it: This method is critical for researchers, quality control analysts, and material scientists working with polymers, proteins, and other macromolecules. Anyone involved in polymer synthesis, characterization, formulation, or research requiring precise information about the size and distribution of molecules will find SEC invaluable. Understanding the molecular weight distribution is crucial as it directly impacts a material's physical properties, such as viscosity, tensile strength, and processability.

Common misconceptions: A common misconception is that SEC directly measures molecular weight. Instead, it separates based on hydrodynamic volume, and molecular weight is *inferred* via calibration with standards. Another mistake is assuming all SEC systems yield identical results; differences in columns, mobile phases, and detectors can significantly impact elution behavior. Lastly, assuming ideal behavior without considering potential polymer-column interactions (adsorption, aggregation) can lead to inaccurate results in molecular weight determination. Proper calibration and method validation are key to accurate size exclusion chromatography molecular weight calculations.

Size Exclusion Chromatography Molecular Weight Formula and Mathematical Explanation

The calculation of molecular weight from Size Exclusion Chromatography (SEC) data typically involves a multi-step process, starting with the experimental data (retention times and known standards) and progressing to a calibrated molecular weight for the unknown sample. The core of the method relies on establishing a relationship between a molecule's size and its elution behavior, and then extrapolating this relationship to determine the molecular weight of an unknown.

The fundamental equation relating elution behavior to molecular size is often expressed through the partition coefficient, Kav, or a related hydrodynamic volume parameter. For many polymer-solution systems, the logarithm of the molecular weight (log10(MW)) exhibits a linear relationship with the logarithm of the hydrodynamic volume or with a parameter directly related to retention time.

A common approach involves plotting log10(MW) of known standards against their corresponding Kav values (or normalized retention times). The Kav is typically calculated as:

Kav = (Ve – V0) / (Vt – V0)

Where:

  • Ve is the elution volume of the sample (in mL).
  • V0 is the void volume (elution volume of an excluded molecule, in mL).
  • Vt is the total permeation volume (elution volume of a totally included molecule, in mL).

However, the calculator provided uses a simplified relation where Ve is directly represented by the sample's retention time (tR), and Kav is a term that correlates with (tR – t0) / (Vt – V0) or a similar normalized retention volume, where t0 is the void time. For simplicity in this calculator, we directly use retention time (tR) as a proxy that is then mapped to Kav derived from calibration.

Once the calibration data (pairs of Kav and log10(MW) for standards) are obtained, a calibration curve is constructed. This is often a linear regression fit, yielding an equation of the form:

log10(MW) = m * log10(Kav) + c

Or, if retention time (tR) is directly used in relation to a normalized Kav:

log10(MW) = m * (tR – toffset) + c

Where 'm' is the slope and 'c' is the intercept of the calibration line. The calculator simplifies this by directly mapping provided Kav values to log10(MW) and interpolating for the sample's Kav, derived from its retention time (tR) and the column parameters (V0, Vt).

Given a sample's retention time (tR), we first calculate its corresponding Kav value. If the calibration data is provided as Kav vs. log10(MW) pairs, and the sample's retention time tR corresponds to a certain Kav value, the calculator finds the associated log10(MW) using interpolation or regression based on the provided calibration points.

Then, the molecular weight (MW) is found by taking the antilogarithm:

MW = 10(log10(MW))

This process yields the *absolute* molecular weight if universal calibration (using log10(MW * [η]), where [η] is intrinsic viscosity) or accurate standards are used. The calculator primarily performs *relative* molecular weight determination based on the provided Kav-log10(MW) relationship.

Variables Explained:

Variable Meaning Unit Typical Range
tR Sample Retention Time minutes Varies widely depending on system and sample (e.g., 10-50 min)
V0 Void Volume (Dead Volume) mL Typically 5-15 mL for standard columns
Vex Exclusion Limit Volume mL Volume where molecules are fully excluded; often near V0
Vt Total Permeation Volume mL Volume where molecules are totally included; varies with column packing
Kav Partition Coefficient Unitless 0 to 1 (or higher depending on normalization)
log10(MW) Logarithm (base 10) of Molecular Weight Unitless Varies widely (e.g., 2 to 7+)
MW Molecular Weight g/mol or Da Varies widely (e.g., 1,000 to 1,000,000+)
m Slope of Calibration Curve Unitless Typically negative (e.g., -0.5 to -1.5)
c Intercept of Calibration Curve Unitless Varies based on standards and curve fit

Practical Examples of Size Exclusion Chromatography Molecular Weight Determination

SEC is applied across numerous fields, providing critical molecular weight data. Here are two practical examples:

Example 1: Characterizing a Synthetic Polymer Batch

Scenario: A chemical company synthesizes a batch of polystyrene. Quality control requires verifying its molecular weight distribution. They run the sample on an SEC system calibrated with narrow molecular weight distribution polystyrene standards.

Inputs:

  • Sample Retention Time (tR): 22.0 minutes
  • Void Volume (V0): 7.5 mL
  • Total Volume (Vt): 28.0 mL
  • Calibration Data: (provided in calculator, representing various MW standards)

Process (as performed by the calculator):

  1. The calculator first uses the provided calibration data (Kav vs. log10(MW) or equivalent retention time vs. log10(MW)) to establish a regression line or interpolation model.
  2. It calculates the Kav for the sample based on its retention time and column parameters. For instance, if using a Ve interpretation: Kav = (tR * flow_rate – V0) / (Vt – V0). Assuming a flow rate of 1 mL/min, Ve = 22.0 mL. Kav = (22.0 – 7.5) / (28.0 – 7.5) = 14.5 / 20.5 ≈ 0.707.
  3. Using the calibration curve derived from standards, the calculator finds the log10(MW) corresponding to this Kav (or directly from the tR). Let's assume the calibration yields log10(MW) = 4.85 for this Kav.
  4. The final molecular weight is calculated: MW = 104.85 ≈ 70,795 g/mol.

Output:

  • Calculated MW: ~70,795 g/mol
  • Intermediate values (Kav, log10(MW)) displayed.

Interpretation: This result provides an estimate of the peak molecular weight (Mp) for this polystyrene batch. QC checks compare this value against specifications. Significant deviations might indicate issues in the polymerization process.

Example 2: Analyzing Protein Aggregation

Scenario: A pharmaceutical company is investigating the stability of a therapeutic protein. They suspect that the protein may be forming aggregates during storage. SEC is used to detect and quantify these aggregates.

Inputs:

  • Sample Retention Time (tR): 18.5 minutes
  • Void Volume (V0): 8.2 mL
  • Total Volume (Vt): 32.0 mL
  • Calibration Data: (provided in calculator, using protein standards of known MW)

Process:

  1. Similar to Example 1, the calculator uses the calibration curve.
  2. Calculate Kav. Assuming flow rate 1 mL/min, Ve = 18.5 mL. Kav = (18.5 – 8.2) / (32.0 – 8.2) = 10.3 / 23.8 ≈ 0.433.
  3. The calibration curve, constructed from monomeric protein standards, yields a log10(MW) corresponding to Kav ≈ 0.433. Let's say this gives log10(MW) = 5.20.
  4. MW = 105.20 ≈ 158,489 g/mol.

Output:

  • Calculated MW: ~158,489 g/mol

Interpretation: The expected molecular weight of the monomeric protein is around 50,000 g/mol. The calculated MW of ~158,000 g/mol strongly suggests the presence of a trimer (3 x 50,000 ≈ 150,000). This indicates significant protein aggregation, which could affect the drug's efficacy and safety. Further investigation into storage conditions would be warranted. This example highlights how size exclusion chromatography molecular weight calculations aid in assessing drug product quality.

How to Use This Size Exclusion Chromatography Molecular Weight Calculator

Our Size Exclusion Chromatography (SEC) Molecular Weight Calculator is designed to be intuitive and user-friendly, helping you quickly estimate the molecular weight of your samples based on SEC data and a calibration curve.

  1. Input Sample Retention Time (tR): Enter the time, in minutes, at which your sample eluted from the SEC column. This is a critical measurement obtained from your chromatogram.
  2. Enter Column Parameters: Input the Void Volume (V0) and Total Volume (Vt) of your SEC column. These are intrinsic properties of the chromatography system and are usually provided by the column manufacturer or determined experimentally. Also, input the Exclusion Limit (Vex) if your calculation method relies on it for Kav normalization.
  3. Provide Calibration Data: This is the most crucial step for accurate molecular weight determination. Enter your calibration data in the provided text area. Each line should contain a pair of values: the partition coefficient (Kav) or a value directly proportional to it (like normalized retention volume), and the logarithm of the molecular weight (log10(MW)) of the corresponding known standard. Use the format `K_av, log10(MW)`. For example: `0.1, 5.0` followed by `0.5, 4.5`. The calculator will use this data to build a calibration curve (or interpolate).
  4. Calculate: Click the "Calculate Molecular Weight" button. The calculator will process your inputs, derive the Kav for your sample, use the calibration data to find the corresponding log10(MW), and then calculate the final molecular weight.
  5. Review Results: The primary result (Molecular Weight) will be displayed prominently. You will also see key intermediate values like Kav and log10(MW), along with the formula explanation and key assumptions. The calibration curve and your sample's position on it will be visualized in the chart.
  6. Reset: If you need to start over or input new data, click the "Reset" button to revert the fields to sensible default values.
  7. Copy Results: Use the "Copy Results" button to quickly copy the calculated molecular weight, intermediate values, and assumptions for reporting or documentation.

How to Read Results: The main number displayed is your estimated molecular weight. The intermediate values provide insight into the calculation steps. The chart visually confirms if your sample falls within the range of your calibration standards. If your sample point is far outside the calibration range, the calculated molecular weight may be less reliable.

Decision-Making Guidance: Compare the calculated molecular weight against your expected values or specifications. Deviations can signal problems with your sample, your calibration standards, or your experimental setup. For example, a calculated MW significantly higher than expected might indicate protein aggregation or polymer branching, while a lower MW could suggest sample degradation or instrumental issues. Accurate Size Exclusion Chromatography molecular weight determination is key to making informed decisions about sample integrity and material properties.

Key Factors That Affect Size Exclusion Chromatography Molecular Weight Results

Accurate molecular weight determination using SEC relies on several critical factors. Variations in these can significantly impact the results obtained from your Size Exclusion Chromatography molecular weight calculations.

  • Calibration Standards: The choice and quality of calibration standards are paramount. They must be chemically similar to the analyte (e.g., polystyrene standards for polystyrene samples), have narrow molecular weight distributions, and cover the molecular weight range of interest. Using inappropriate standards (e.g., polymer standards for proteins) leads to inaccurate "apparent" molecular weights.
  • Column Performance and Choice: SEC columns are designed with specific pore sizes and chemistries to separate molecules within certain ranges. Using a column inappropriate for your sample's molecular weight range will result in poor separation (e.g., sample eluting at V0 or Vt) and unreliable calculations. Column degradation over time also affects retention times and thus calculated MW.
  • Mobile Phase Composition: The mobile phase (solvent) plays a crucial role. It must keep the analyte and standards soluble, prevent adsorption to the column, and avoid aggregation. Changes in solvent strength, pH, or ionic strength can alter the hydrodynamic volume of polymers or proteins, affecting elution behavior and the calculated molecular weight. For accurate size exclusion chromatography molecular weight, the mobile phase must be consistent.
  • Temperature Control: SEC systems often incorporate a column oven to maintain a constant temperature. Temperature fluctuations can affect solvent viscosity and polymer chain dynamics, leading to variations in retention times and calculated molecular weights. Stable temperatures are essential for reproducible results.
  • Instrumental Factors (Flow Rate, Detector): Consistent flow rate is critical, as retention times are directly measured. Deviations from the calibrated flow rate alter Ve and thus Kav. Detector settings (e.g., refractive index sensitivity, UV absorbance) and response time can also influence the accuracy of peak detection and integration, impacting the calculated molecular weight distribution.
  • Analyte Behavior (Non-Ideality): Real-world samples may not behave ideally. Polymers can exhibit specific interactions (adsorption) with the stationary phase, leading to longer retention times and overestimation of MW. Conversely, aggregation or association of molecules can cause them to elute earlier than expected, potentially indicating higher MW. Understanding and mitigating these non-ideal behaviors is vital for accurate size exclusion chromatography molecular weight assessment.
  • Data Processing and Calibration Model: The method used to generate the calibration curve (e.g., linear regression, polynomial fit) and how the sample's retention time is mapped onto this curve significantly influences the final calculated molecular weight. The calculator uses interpolation/regression based on provided data, assuming the chosen model accurately represents the relationship.

Frequently Asked Questions (FAQ) about SEC Molecular Weight

Q1: Can I use universal calibration for any polymer?

A: Universal calibration, which plots log10([η]MW) vs. elution volume, is more universally applicable than single-polymer calibration because it accounts for differences in polymer chain dimensions. However, it requires accurate measurement of intrinsic viscosity ([η]) for each polymer type, which can be challenging. It's most effective when standards and samples have similar hydrodynamic behaviors.

Q2: My sample eluted much faster than expected. What could be wrong?

A: This often indicates that the molecule is larger than the calibration standards used, or that the sample has aggregated. It could also be due to adsorption onto the column, which is a form of non-ideal SEC behavior. Ensure your standards span the molecular weight range of your sample and consider using additives in your mobile phase to minimize adsorption.

Q3: What is the difference between Mn, Mw, and Mp?

A: These are key metrics of molecular weight distribution. Mn (Number average molecular weight) is the total weight of all molecules divided by the total number of molecules. Mw (Weight average molecular weight) is a sum weighted by molecular weight, sensitive to larger molecules. Mp (Peak molecular weight) is the molecular weight at the highest point of the chromatogram. The calculated value in this calculator typically represents Mp or Mw depending on the calibration method and data processed.

Q4: How often should I re-calibrate my SEC system?

A: Re-calibration frequency depends on system stability and usage. Daily or weekly checks with a reference standard are recommended. A full re-calibration using a broad range of standards should be performed when system components are changed (e.g., new column), mobile phase is altered, or significant drift in results is observed. Regular calibration is vital for reliable size exclusion chromatography molecular weight.

Q5: Can SEC determine the molecular structure of a polymer?

A: No, SEC primarily determines molecular weight and distribution based on size. It does not provide information about the chemical structure, branching architecture, or tacticity of a polymer. Techniques like NMR spectroscopy or Mass Spectrometry are needed for structural analysis.

Q6: What is the role of the void volume (V0) and total volume (Vt)?

A: V0 represents the volume of mobile phase accessible to molecules that are too large to enter the pores of the stationary phase (elute first). Vt represents the total volume of mobile phase within the column and pores accessible to small molecules that can explore the entire column volume (elute last). These values are crucial for normalizing retention volumes and calculating parameters like Kav, which are used in the SEC molecular weight calculation.

Q7: How does high-temperature SEC differ?

A: High-temperature SEC (HT-SEC) is used for polymers that are insoluble or difficult to process at room temperature, such as polyolefins (polyethylene, polypropylene). It requires specialized heated columns, instruments, and mobile phases (e.g., trichlorobenzene). The principles of molecular weight determination remain similar, but experimental conditions are significantly different.

Q8: Can this calculator be used for proteins?

A: Yes, provided you use appropriate protein standards for calibration and a compatible mobile phase (often buffered aqueous solutions). The fundamental principle of separation by hydrodynamic volume applies. Ensure your calibration data (Kav vs. log10(MW)) reflects protein standards.

Related Tools and Internal Resources

© 2023 Your Company Name. All rights reserved. | Disclaimer: This calculator provides estimates for educational and informational purposes only. Always validate results with rigorous experimental procedures.

// Function to validate input fields function validateInputs() { var retentionTime = document.getElementById("retentionTime").value; var voidVolume = document.getElementById("voidVolume").value; var exclusionLimit = document.getElementById("exclusionLimit").value; var totalVolume = document.getElementById("totalVolume").value; var calibrationData = document.getElementById("calibrationData").value; var isValid = true; // Reset errors document.getElementById("retentionTimeError").style.display = 'none'; document.getElementById("voidVolumeError").style.display = 'none'; document.getElementById("exclusionLimitError").style.display = 'none'; document.getElementById("totalVolumeError").style.display = 'none'; document.getElementById("calibrationDataError").style.display = 'none'; if (retentionTime === "" || isNaN(parseFloat(retentionTime)) || parseFloat(retentionTime) < 0) { document.getElementById("retentionTimeError").textContent = "Please enter a valid positive number for retention time."; document.getElementById("retentionTimeError").style.display = 'block'; isValid = false; } if (voidVolume === "" || isNaN(parseFloat(voidVolume)) || parseFloat(voidVolume) <= 0) { document.getElementById("voidVolumeError").textContent = "Please enter a valid positive number for void volume."; document.getElementById("voidVolumeError").style.display = 'block'; isValid = false; } if (exclusionLimit === "" || isNaN(parseFloat(exclusionLimit)) || parseFloat(exclusionLimit) < 0) { document.getElementById("exclusionLimitError").textContent = "Please enter a valid non-negative number for exclusion limit."; document.getElementById("exclusionLimitError").style.display = 'block'; isValid = false; } if (totalVolume === "" || isNaN(parseFloat(totalVolume)) || parseFloat(totalVolume) = parseFloat(totalVolume)) { document.getElementById("totalVolumeError").textContent = "Total volume must be greater than void volume."; document.getElementById("totalVolumeError").style.display = 'block'; isValid = false; } if (parseFloat(exclusionLimit) >= parseFloat(totalVolume)) { document.getElementById("exclusionLimitError").textContent = "Exclusion limit must be less than total volume."; document.getElementById("exclusionLimitError").style.display = 'block'; isValid = false; } if (parseFloat(exclusionLimit) < parseFloat(voidVolume)) { document.getElementById("exclusionLimitError").textContent = "Exclusion limit should generally be greater than or equal to void volume."; document.getElementById("exclusionLimitError").style.display = 'block'; // Not strictly invalid, but a warning } var calibrationLines = calibrationData.trim().split('\n'); var parsedCalibrationData = []; var calibrationDataValid = true; if (calibrationLines.length < 2) { document.getElementById("calibrationDataError").textContent = "Please provide at least two calibration data points."; document.getElementById("calibrationDataError").style.display = 'block'; isValid = false; calibrationDataValid = false; } else { for (var i = 0; i = 0 && logMw !== null) { // K_av usually >= 0 parsedCalibrationData.push({ kav: kav, logMw: logMw }); } else { document.getElementById("calibrationDataError").textContent = "Invalid format or value in calibration data on line " + (i + 1) + ". Use 'K_av, log10(MW)'."; document.getElementById("calibrationDataError").style.display = 'block'; isValid = false; calibrationDataValid = false; break; } } else { document.getElementById("calibrationDataError").textContent = "Invalid format on calibration data line " + (i + 1) + ". Use 'K_av, log10(MW)'."; document.getElementById("calibrationDataError").style.display = 'block'; isValid = false; calibrationDataValid = false; break; } } // Sort data by K_av for interpolation if (calibrationDataValid) { parsedCalibrationData.sort(function(a, b) { return a.kav – b.kav; }); // Check if sample K_av will be within range var sampleKav = calculateKav(parseFloat(retentionTime), parseFloat(voidVolume), parseFloat(totalVolume)); if (sampleKav !== null && (sampleKav parsedCalibrationData[parsedCalibrationData.length – 1].kav)) { document.getElementById("calibrationDataError").textContent = "Sample K_av is outside the calibration range. Extrapolation may be unreliable."; document.getElementById("calibrationDataError").style.display = 'block'; // This is a warning, not a complete stop, but it's good to flag. } } } return isValid ? parsedCalibrationData : null; } // Function to calculate K_av function calculateKav(retentionTime, voidVolume, totalVolume) { // Simplified K_av calculation based on relative elution volumes. // Actual K_av can be derived from (Ve – V0) / (Vt – V0) or normalized retention times. // For this calculator, we'll use a proxy that relates retention time to the (V0, Vt) range. // A common normalization is (tR – t0) / (t1 – t0) where t0 is void time and t1 is total permeation time. // Let's approximate t0 proportional to V0 and t1 proportional to Vt. // If tR maps linearly to the K_av range [0, 1] from V0 to Vt: // K_av_proxy = (retentionTime – V0_proxy_time) / (Vt_proxy_time – V0_proxy_time) // A simpler approach for direct mapping if calibration is K_av vs log10(MW): // Calculate a normalized retention volume (VR) // VR = (Ve – V0) / (Vt – V0) // Assuming Ve is proportional to tR, V0 to t0 (void time), Vt to t1 (total time): // t0 is roughly proportional to V0. Let's assume t0 = V0 / flowrate and t1 = Vt / flowrate. // If flowrate = 1 mL/min, then Ve=tR, V0=V0, Vt=Vt. // So, Kav_approx = (retentionTime – voidVolume) / (totalVolume – voidVolume) if retentionTime represents Ve. // Let's stick to K_av = (Ve – V0) / (Vt – V0) where Ve is implied by tR. // If we assume tR scales linearly with Ve, and V0/Vt are volumes: // It's more standard to use K = (Ve – V0) / (Vt – V0). // The calculator needs a K_av value to look up on the calibration curve. // Let's directly use (retentionTime – V0) / (Vt – V0) as our "K_av" proxy if tR is effectively Ve. // This needs careful interpretation based on how the calibration data is provided. // The calibration data is provided as K_av, log10(MW). So we MUST produce a K_av. // K_av = (Ve – V0) / (Vt – V0). Here Ve corresponds to the elution volume of the sample. // If we assume flow rate is constant and Ve ~ tR, then K_av_sample ~ (tR_sample – V0) / (Vt – V0) // This requires careful unit consistency (mL). If tR is in minutes, and V0/Vt are in mL, // this implies a flow rate of 1 mL/min for Ve to be numerically equal to tR. // Let's assume this implicit flow rate for K_av calculation. var sampleVe = retentionTime; // Assuming Ve numerically equals tR in mL when flow is 1 mL/min if (totalVolume – voidVolume <= 0) return null; // Avoid division by zero var kav = (sampleVe – voidVolume) / (totalVolume – voidVolume); // Clamp K_av between 0 and 1, as it represents a relative partitioning. // Molecules larger than exclusion limit should have K_av = 0 (or close to it). // Molecules smaller than total permeation limit should have K_av = 1 (or close to it). // Our formula might yield values outside [0,1] if tR is outside [V0, Vt] range. // A K_av of 0 implies exclusion, K_av of 1 implies total permeation. // Let's refine: Kav calculation often uses (Ve – V0) / (Vi – V0) where Vi is inclusion volume. // If the calibration data is provided as K_av, log10(MW), we need to generate *that* K_av. // Let's assume the calibration data uses K_av = (Ve – V0) / (Vt – V0). // Therefore, our sample K_av should be calculated consistently. // If sample tR is LESS than V0 (e.g., void time), it's fully excluded, K_av ~ 0. // If sample tR is GREATER than Vt, it's fully included, K_av ~ 1. if (retentionTime totalVolume) return 1; // Fully included return (retentionTime – voidVolume) / (totalVolume – voidVolume); // Linear interpolation between V0 and Vt } // Function for linear interpolation function interpolateLogMw(kav, calibrationData) { if (kav calibrationData[calibrationData.length – 1].kav) return calibrationData[calibrationData.length – 1].logMw; // After last point, use last value for (var i = 0; i = calibrationData[i].kav && kav <= calibrationData[i + 1].kav) { var x1 = calibrationData[i].kav; var y1 = calibrationData[i].logMw; var x2 = calibrationData[i + 1].kav; var y2 = calibrationData[i + 1].logMw; // Linear interpolation formula: y = y1 + (x – x1) * (y2 – y1) / (x2 – x1) var logMw = y1 + (kav – x1) * (y2 – y1) / (x2 – x1); return logMw; } } return NaN; // Should not reach here if kav is within bounds } // Main calculation function function calculateMW() { var parsedCalibrationData = validateInputs(); if (!parsedCalibrationData) { document.getElementById("molecularWeightResult").textContent = "–"; document.getElementById("kavResult").querySelector("span").textContent = "–"; document.getElementById("logMwResult").querySelector("span").textContent = "–"; document.getElementById("calculatedMwResult").querySelector("span").textContent = "–"; updateChart([], null, null); // Clear chart return; } var retentionTime = parseFloat(document.getElementById("retentionTime").value); var voidVolume = parseFloat(document.getElementById("voidVolume").value); var totalVolume = parseFloat(document.getElementById("totalVolume").value); var sampleKav = calculateKav(retentionTime, voidVolume, totalVolume); var logMw = interpolateLogMw(sampleKav, parsedCalibrationData); var molecularWeight = Math.pow(10, logMw); document.getElementById("molecularWeightResult").textContent = molecularWeight.toExponential(2) + " g/mol"; document.getElementById("kavResult").querySelector("span").textContent = sampleKav.toFixed(3); document.getElementById("logMwResult").querySelector("span").textContent = logMw.toFixed(3); document.getElementById("calculatedMwResult").querySelector("span").textContent = molecularWeight.toExponential(2) + " g/mol"; updateChart(parsedCalibrationData, sampleKav, logMw); } // Reset calculator to default values function resetCalculator() { document.getElementById("retentionTime").value = "25.5"; document.getElementById("voidVolume").value = "8.0"; document.getElementById("exclusionLimit").value = "2.0"; // This is not directly used in MW calc but good to reset document.getElementById("totalVolume").value = "30.0"; document.getElementById("calibrationData").value = "0.1, 5.0\n0.5, 4.5\n1.0, 4.0\n1.5, 3.5\n2.0, 3.0"; // Clear errors document.getElementById("retentionTimeError").style.display = 'none'; document.getElementById("voidVolumeError").style.display = 'none'; document.getElementById("exclusionLimitError").style.display = 'none'; document.getElementById("totalVolumeError").style.display = 'none'; document.getElementById("calibrationDataError").style.display = 'none'; calculateMW(); // Recalculate with defaults } // Copy results to clipboard function copyResults() { var mainResult = document.getElementById("molecularWeightResult").textContent; var kav = document.getElementById("kavResult").querySelector("span").textContent; var logMw = document.getElementById("logMwResult").querySelector("span").textContent; var calculatedMw = document.getElementById("calculatedMwResult").querySelector("span").textContent; var assumptions = "Key Assumptions:\n"; var assumptionsDivs = document.querySelectorAll('#results .key-assumptions div'); for (var i = 0; i 0 ? kavPadding : 0.5; logMwPadding = logMwPadding > 0 ? logMwPadding : 0.5; myChart = new Chart(ctx, { type: 'scatter', data: { datasets: [{ label: 'Calibration Curve Standards', data: calibrationPoints.map(function(p) { return { x: p.kav, y: p.logMw }; }), backgroundColor: 'rgba(0, 74, 153, 0.6)', // Primary color borderColor: 'rgba(0, 74, 153, 1)', borderWidth: 1, pointRadius: 5, showLine: false // We will draw a line separately if needed, but scatter is good for points }, { label: 'Interpolated Line', data: calibrationPoints.map(function(p) { return { x: p.kav, y: p.logMw }; }), // Use calibration points to draw line borderColor: 'rgba(40, 167, 69, 0.8)', // Success color for line borderWidth: 2, pointRadius: 0, showLine: true, // Draw the line fill: false }] }, options: { responsive: true, maintainAspectRatio: false, // Allow custom height/width scales: { x: { type: 'linear', position: 'bottom', title: { display: true, label: 'Kav (Partition Coefficient)', font: { size: 14, weight: 'bold' }, color: 'var(–primary-color)' }, min: minKav – kavPadding, max: maxKav + kavPadding, grid: { color: 'rgba(200, 200, 200, 0.3)' } }, y: { title: { display: true, label: 'log10(Molecular Weight)', font: { size: 14, weight: 'bold' }, color: 'var(–primary-color)' }, min: minLogMw – logMwPadding, max: maxLogMw + logMwPadding, grid: { color: 'rgba(200, 200, 200, 0.3)' } } }, plugins: { legend: { display: false // Hide legend, will use custom labels/tooltips if needed }, tooltip: { callbacks: { label: function(context) { var label = context.dataset.label || "; if (label) { label += ': '; } if (context.parsed.x !== null && context.parsed.y !== null) { label += `Kav=${context.parsed.x.toFixed(3)}, log10(MW)=${context.parsed.y.toFixed(3)}`; } return label; } } } } } }); // Add the sample point if valid data exists if (sampleKav !== null && !isNaN(sampleKav) && sampleLogMw !== null && !isNaN(sampleLogMw)) { myChart.data.datasets.push({ label: 'Sample Point', data: [{ x: sampleKav, y: sampleLogMw }], backgroundColor: 'rgba(255, 99, 132, 1)', // Red for sample point borderColor: 'rgba(255, 99, 132, 1)', pointRadius: 7, pointHoverRadius: 9 }); myChart.update(); // Update chart to include the new dataset } } // Initial calculation on page load document.addEventListener('DOMContentLoaded', function() { calculateMW(); // Set canvas dimensions for better aspect ratio control if needed var canvas = document.getElementById('calibrationChart'); canvas.width = 700; // Example width canvas.height = 400; // Example height // Re-run calculation after dimensions are set, if needed calculateMW(); }); // Inject Chart.js dynamically if not present if (typeof Chart === 'undefined') { var script = document.createElement('script'); script.src = 'https://cdn.jsdelivr.net/npm/chart.js@3.9.1/dist/chart.min.js'; // Use a specific version script.onload = function() { console.log("Chart.js loaded."); // Recalculate after Chart.js is loaded calculateMW(); }; script.onerror = function() { console.error("Failed to load Chart.js"); }; document.head.appendChild(script); } else { // Chart.js already loaded, ensure calculation happens calculateMW(); }

Leave a Comment