Conduit and Wire Weight Calculator | Calculate Electrical Load Capacity :root { –primary-color: #004a99; –success-color: #28a745; –background-color: #f8f9fa; –text-color: #333; –light-gray: #e9ecef; –white: #fff; –border-radius: 5px; } body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; background-color: var(–background-color); color: var(–text-color); line-height: 1.6; margin: 0; padding: 20px; display: flex; flex-direction: column; align-items: center; } .container { max-width: 960px; width: 100%; background-color: var(–white); padding: 30px; border-radius: var(–border-radius); box-shadow: 0 4px 15px rgba(0, 0, 0, 0.08); margin-bottom: 40px; } h1, h2, h3 { color: var(–primary-color); text-align: center; margin-bottom: 20px; } h1 { font-size: 2.2em; margin-top: 0; } h2 { font-size: 1.8em; border-bottom: 2px solid var(–primary-color); padding-bottom: 10px; margin-top: 30px; } h3 { font-size: 1.4em; margin-top: 25px; } .calc-wrapper { background-color: var(–white); padding: 30px; border-radius: var(–border-radius); box-shadow: 0 2px 10px rgba(0, 0, 0, 0.05); margin-bottom: 30px; } .input-group { margin-bottom: 20px; padding: 15px; background-color: var(–light-gray); border-radius: var(–border-radius); display: flex; flex-direction: column; } .input-group label { font-weight: bold; margin-bottom: 8px; color: var(–primary-color); } .input-group input[type="number"], .input-group select { padding: 10px; border: 1px solid var(–light-gray); border-radius: var(–border-radius); font-size: 1em; width: calc(100% – 22px); /* Account for padding and border */ } .input-group small { color: #6c757d; margin-top: 8px; font-size: 0.9em; } .error-message { color: #dc3545; font-size: 0.85em; margin-top: 5px; min-height: 1.2em; /* Reserve space to prevent layout shifts */ } button { background-color: var(–primary-color); color: var(–white); border: none; padding: 12px 25px; border-radius: var(–border-radius); cursor: pointer; font-size: 1.1em; margin-right: 10px; transition: background-color 0.3s ease; margin-top: 10px; } button:hover { background-color: #003366; } button.reset-btn { background-color: #6c757d; } button.reset-btn:hover { background-color: #5a6268; } button.copy-btn { background-color: #17a2b8; } button.copy-btn:hover { background-color: #117a8b; } .results-container { background-color: var(–primary-color); color: var(–white); padding: 25px; border-radius: var(–border-radius); margin-top: 30px; text-align: center; box-shadow: 0 4px 10px rgba(0, 74, 153, 0.3); } .results-container h3 { color: var(–white); margin-top: 0; margin-bottom: 15px; font-size: 1.6em; } .primary-result { font-size: 2.5em; font-weight: bold; margin-bottom: 15px; display: block; padding: 10px; background-color: var(–success-color); border-radius: var(–border-radius); } .intermediate-results div { margin-bottom: 10px; font-size: 1.1em; } .intermediate-results span { font-weight: bold; } .formula-explanation { font-size: 0.95em; margin-top: 20px; padding: 15px; background-color: var(–light-gray); border-left: 4px solid var(–primary-color); } table { width: 100%; border-collapse: collapse; margin-top: 30px; margin-bottom: 30px; box-shadow: 0 2px 8px rgba(0, 0, 0, 0.05); } th, td { padding: 12px; text-align: left; border-bottom: 1px solid var(–light-gray); } th { background-color: var(–primary-color); color: var(–white); font-weight: bold; } td { background-color: var(–white); } tr:hover { background-color: var(–light-gray); } caption { caption-side: top; font-weight: bold; font-size: 1.2em; color: var(–primary-color); margin-bottom: 15px; text-align: left; } canvas { margin-top: 30px; border: 1px solid var(–light-gray); border-radius: var(–border-radius); background-color: var(–white); box-shadow: 0 2px 8px rgba(0, 0, 0, 0.05); } .chart-container { text-align: center; margin-top: 20px; } .chart-caption { font-size: 0.9em; color: #6c757d; margin-top: 10px; display: block; } .article-content { background-color: var(–white); padding: 30px; border-radius: var(–border-radius); box-shadow: 0 4px 15px rgba(0, 0, 0, 0.08); margin-bottom: 40px; text-align: left; } .article-content h2, .article-content h3 { text-align: left; color: var(–primary-color); border-bottom: 1px solid var(–primary-color); padding-bottom: 5px; } .article-content p { margin-bottom: 15px; } .article-content ul, .article-content ol { margin-left: 20px; margin-bottom: 15px; } .article-content li { margin-bottom: 8px; } .article-content a { color: var(–primary-color); text-decoration: none; font-weight: bold; } .article-content a:hover { text-decoration: underline; } .faq-item { margin-bottom: 20px; border: 1px solid var(–light-gray); padding: 15px; border-radius: var(–border-radius); background-color: var(–white); } .faq-item h4 { margin: 0 0 10px 0; color: var(–primary-color); font-size: 1.1em; cursor: pointer; } .faq-item p { margin: 0; font-size: 0.95em; display: none; /* Initially hidden */ } .faq-item.open p { display: block; } .related-links { list-style: none; padding: 0; } .related-links li { margin-bottom: 15px; border-bottom: 1px dashed var(–light-gray); padding-bottom: 10px; } .related-links li:last-child { border-bottom: none; } /* Responsive adjustments */ @media (max-width: 768px) { .container { padding: 20px; } h1 { font-size: 1.8em; } h2 { font-size: 1.5em; } .primary-result { font-size: 2em; } }

Conduit and Wire Weight Calculator

Calculate the estimated weight of conduit and the wires within it for your electrical projects, aiding in material estimation and structural load considerations.

Conduit and Wire Weight Calculator

EMT (Electrical Metallic Tubing) – 0.63 lbs/ft IMC (Intermediate Metal Conduit) – 1.00 lbs/ft Rigid (Rigid Metal Conduit) – 1.45 lbs/ft PVC (Polyvinyl Chloride) – 0.20 lbs/ft Select the type of electrical conduit used.
Nominal trade size diameter of the conduit in inches (e.g., 0.5, 1, 1.25, 2, 3, 4).
Total length of the conduit run in feet.
The total count of electrical wires inside the conduit.
14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG 2 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG Select the American Wire Gauge (AWG) of the conductors.
Copper (20.7 lbs/kft) Aluminum (6.6 lbs/kft) Choose between Copper or Aluminum conductors.
THHN (3.0mm Dia, ~0.7 lbs/kft) – Common XHHW (3.5mm Dia, ~0.9 lbs/kft) TW (2.5mm Dia, ~0.5 lbs/kft) Select the insulation type, affecting wire diameter and weight.

Estimated Weights

Conduit Weight:
Weight per Wire:
Total Wire Weight:
How it's calculated:

Conduit Weight: (Conduit Weight per Foot) * (Conduit Length)

Wire Weight: (Wire Weight per kft based on Material & Gauge) / 1000 * (Conduit Length)

Total Wire Weight: (Weight per Wire) * (Number of Wires)

Weight Breakdown Table

Weight Estimation Details
Component Unit Weight Quantity Total Weight
Conduit
Single Wire

Weight Distribution Chart

Comparison of total conduit weight vs. total wire weight.

What is the Conduit and Wire Weight Calculator?

The Conduit and Wire Weight Calculator is a specialized online tool designed to estimate the total weight of electrical conduit and the conductors (wires) contained within it. This calculation is crucial for various stages of electrical project planning, from initial material procurement to structural engineering assessments. By inputting specific details about the conduit type, size, length, wire gauge, and material, users can obtain accurate weight estimations.

This calculator is indispensable for electrical contractors, project managers, structural engineers, and maintenance personnel. It helps in:

  • Accurately ordering the correct amount of materials, minimizing waste and additional shipping costs.
  • Determining the structural load capacity requirements for supports, hangers, and enclosures.
  • Planning for transportation and installation logistics, especially for large or complex projects.
  • Ensuring compliance with electrical codes and safety standards that may have weight-related considerations.

A common misconception is that wire weight is negligible. However, for large gauges or long runs, the combined weight of multiple conductors can be substantial and significantly impact the overall load. Another misconception is that all conduit types have similar weights; materials like steel conduit are significantly heavier than PVC.

Conduit and Wire Weight Formula and Mathematical Explanation

The Conduit and Wire Weight Calculator utilizes a straightforward set of formulas based on material properties and project specifications. The core idea is to calculate the weight of the conduit and the wires separately, then sum them up for the total estimated weight.

Conduit Weight Calculation

The weight of the conduit is calculated by multiplying its weight per unit length by the total length of the conduit run. The weight per foot varies based on the conduit material and its wall thickness.

Formula:

Conduit Weight = Conduit Weight per Foot × Conduit Length

Wire Weight Calculation

The weight of the wires is more complex as it depends on the conductor material (copper or aluminum), the gauge (cross-sectional area), and the length. Wire weights are typically provided per thousand feet (kft).

Formula for one wire:

Weight per Wire = (Wire Weight per kft / 1000) × Conduit Length

The total weight of all wires is then found by multiplying the weight of a single wire by the total number of wires.

Formula for total wire weight:

Total Wire Weight = Weight per Wire × Number of Wires

Total Project Weight

The final output is the sum of the calculated conduit weight and the total wire weight.

Total Estimated Weight = Conduit Weight + Total Wire Weight

Variables and Typical Values

Variable Definitions for Conduit and Wire Weight Calculation
Variable Meaning Unit Typical Range / Notes
Conduit Type Material and standard of the electrical conduit. N/A EMT, IMC, Rigid, PVC
Conduit Weight per Foot The standard weight of the selected conduit type per linear foot. lbs/ft 0.20 (PVC) to 1.45 (Rigid Steel)
Conduit Diameter Nominal trade size of the conduit. Affects capacity and sometimes weight. inches (in) 0.5 to 4 (common)
Conduit Length Total length of the conduit run. feet (ft) 1 to 1000+
Number of Wires Count of individual conductors within the conduit. Count 1 to ~50 (depends on size and fill)
Wire Gauge (AWG) Standard measurement of wire cross-sectional area. AWG 14, 12, 10, 8, 6, 4, 2, 1/0, 2/0, 3/0, 4/0
Wire Material Material of the electrical conductor. N/A Copper, Aluminum
Wire Weight per kft Weight of 1000 feet of a specific gauge and material wire. lbs/kft Varies significantly by gauge and material (e.g., 20.7 lbs/kft for Copper 14 AWG)
Wire Insulation Type Type of insulation jacket on the conductor. Affects diameter and weight. N/A THHN, XHHW, TW
Wire Diameter Approximate diameter of the insulated wire. Used for conduit fill calculations (not directly weight). mm 2.5 to 4.5 (typical)
Total Estimated Weight Sum of conduit and all wire weights. lbs Project dependent

Practical Examples (Real-World Use Cases)

Understanding the practical application of the Conduit and Wire Weight Calculator is key to its effective use. Here are two common scenarios:

Example 1: Standard Residential Service Entrance

Scenario: A contractor is installing a 100-foot run of 2-inch diameter Rigid Metal Conduit for a service entrance. The conduit will contain three 2/0 AWG copper conductors with THHN insulation.

Inputs:

  • Conduit Type: Rigid Metal Conduit (Weight: ~1.45 lbs/ft)
  • Conduit Diameter: 2 inches
  • Conduit Length: 100 feet
  • Number of Wires: 3
  • Wire Gauge: 2/0 AWG
  • Wire Material: Copper (Weight: ~104 lbs/kft for 2/0 AWG Copper)
  • Wire Insulation: THHN

Calculations:

  • Conduit Weight = 1.45 lbs/ft * 100 ft = 145 lbs
  • Weight per Wire = (104 lbs/kft / 1000) * 100 ft = 10.4 lbs
  • Total Wire Weight = 10.4 lbs/wire * 3 wires = 31.2 lbs
  • Total Estimated Weight = 145 lbs + 31.2 lbs = 176.2 lbs

Interpretation: This estimated weight of 176.2 lbs helps the crew plan for lifting and supporting the conduit run. It also informs the structural engineer about the load being added to any supporting structures.

Example 2: Commercial Lighting Circuit

Scenario: A facility manager is assessing material needs for a new lighting circuit using 3/4-inch PVC conduit. The total run is 250 feet and will house four 12 AWG aluminum conductors with XHHW insulation.

Inputs:

  • Conduit Type: PVC Conduit (Weight: ~0.20 lbs/ft)
  • Conduit Diameter: 0.75 inches
  • Conduit Length: 250 feet
  • Number of Wires: 4
  • Wire Gauge: 12 AWG
  • Wire Material: Aluminum (Weight: ~30.5 lbs/kft for 12 AWG Aluminum)
  • Wire Insulation: XHHW

Calculations:

  • Conduit Weight = 0.20 lbs/ft * 250 ft = 50 lbs
  • Weight per Wire = (30.5 lbs/kft / 1000) * 250 ft = 7.625 lbs
  • Total Wire Weight = 7.625 lbs/wire * 4 wires = 30.5 lbs
  • Total Estimated Weight = 50 lbs + 30.5 lbs = 80.5 lbs

Interpretation: The total weight of approximately 80.5 lbs is relatively light, making installation easier. This calculation confirms that PVC is a suitable lightweight option for this application, reducing the load on overhead structures compared to metal conduit.

How to Use This Conduit and Wire Weight Calculator

Using the Conduit and Wire Weight Calculator is designed to be intuitive and straightforward. Follow these steps for accurate results:

  1. Select Conduit Type: Choose the type of conduit you are using (e.g., EMT, IMC, Rigid, PVC) from the dropdown menu. The calculator will automatically use the standard weight per foot for that type.
  2. Enter Conduit Diameter: Input the nominal trade size of the conduit in inches (e.g., 1, 1.25, 2).
  3. Specify Conduit Length: Enter the total length of the conduit run in feet.
  4. Input Number of Wires: State the total quantity of individual conductors that will be pulled through the conduit.
  5. Choose Wire Gauge: Select the American Wire Gauge (AWG) of the conductors from the list.
  6. Select Wire Material: Indicate whether the conductors are made of Copper or Aluminum. This significantly impacts weight.
  7. Choose Wire Insulation Type: Select the insulation type (e.g., THHN, XHHW). While primarily affecting diameter for fill calculations, some types have slightly different weights.
  8. Click 'Calculate Weights': Once all fields are populated, click the button to see the results.

Reading the Results

  • Primary Result (Total Estimated Weight): This large, highlighted number is the sum of the conduit's weight and all the wires' weight in pounds (lbs).
  • Intermediate Results: These provide a breakdown:
    • Conduit Weight: The total calculated weight of the conduit section.
    • Weight per Wire: The estimated weight of a single conductor for the specified length.
    • Total Wire Weight: The combined weight of all conductors in the conduit.
  • Weight Breakdown Table: Offers a clear tabular view of the calculated weights for components.
  • Chart: Visually compares the total weight of the conduit versus the total weight of the wires.

Decision-Making Guidance

Use the results to make informed decisions:

  • Material Ordering: Ensure you order sufficient conduit and wire, accounting for the total weight for shipping and handling.
  • Structural Support: Verify that ceiling grids, supports, or enclosures can handle the combined weight, especially for long runs or heavy conductors.
  • Installation Planning: For heavier runs, plan for mechanical lifting assistance or additional personnel.
  • Code Compliance: Some regulations may indirectly relate to weight through conduit fill percentages or support spacing, which are influenced by the number and size of wires.

Key Factors That Affect Conduit and Wire Weight Results

Several factors influence the accuracy and magnitude of the calculated weights. Understanding these helps in refining estimates and ensuring project success:

  1. Conduit Material and Schedule: Different conduit types (EMT, Rigid, PVC) have vastly different densities. Even within types like PVC, different schedules (e.g., Schedule 40 vs. Schedule 80) affect wall thickness and weight. The calculator uses standard weights for common types.
  2. Wire Gauge (AWG): This is a primary driver of wire weight. Larger gauges (lower AWG numbers like 4/0) have significantly thicker conductors and thus more metal, leading to much higher weights per foot compared to smaller gauges (e.g., 14 AWG).
  3. Conductor Material (Copper vs. Aluminum): Copper is considerably denser than aluminum. For the same gauge and length, copper wires will weigh substantially more than aluminum ones. This choice impacts both weight and cost.
  4. Conduit Length: This is a direct multiplier for both conduit and wire weights. Longer runs naturally result in higher total weights. Accurate measurement of the planned route is critical.
  5. Number of Conductors: The more wires pulled into a conduit, the greater the total weight contribution from the conductors. This also affects conduit fill ratios, potentially limiting the number or size of wires permissible by code.
  6. Insulation Type and Thickness: While the conductor material dominates wire weight, insulation adds bulk and a small amount of weight. Different insulation types (like THHN, XHHW) have varying thicknesses and material densities, slightly affecting the overall wire diameter and weight per foot. The calculator uses typical weights associated with common insulation types.
  7. Conduit Diameter (Nominal): While the calculator uses standard weight-per-foot values based on conduit type, the nominal diameter is critical for determining how many wires can fit. Although not a direct weight input, it's foundational to the wire count and type feasibility.

Frequently Asked Questions (FAQ)

Q1: Does the calculator account for conduit fittings (couplings, connectors, elbows)?

A1: The standard calculator focuses on the straight length of conduit and the wires within. Fittings add weight, but it's typically a small percentage of the total run weight for most projects. For critical structural calculations involving numerous complex bends, specialized calculations might be needed.

Q2: How accurate are the standard weights used for conduit and wire?

A2: The weights used are based on industry standards and manufacturer data for common materials and gauges. Actual weights can vary slightly due to manufacturing tolerances, specific alloy compositions (especially for aluminum), and insulation variations. However, these values provide a highly reliable estimate for most planning purposes.

Q3: Can I use this calculator for imperial wire sizes (e.g., MCM)?

A3: This calculator is configured for standard American Wire Gauge (AWG) sizes. For larger conductors measured in Thousand Circular Mils (MCM), you would need a calculator or data tables specifically referencing those sizes, as their weight characteristics differ.

Q4: What happens if I exceed the maximum number of wires allowed by code?

A4: This calculator does not enforce electrical code limitations on conduit fill. It assumes the user has verified the wire count and size are permissible for the chosen conduit diameter and type according to NEC (National Electrical Code) or local regulations. Exceeding fill limits can cause installation difficulties and code violations.

Q5: Is the weight difference between copper and aluminum significant?

A5: Yes, it's very significant. Copper is about three times denser than aluminum. For the same AWG size and length, copper wire will weigh roughly three times as much as aluminum wire. This affects material handling and structural load considerations.

Q6: Should I use conduit weight or wire weight as the primary factor for structural support?

A6: Both are important. The total combined weight determines the load. However, for long runs with larger gauge wires, the total wire weight can often exceed the conduit weight, especially with aluminum conduit. Always consider the sum of both for structural integrity.

Q7: Does the calculator factor in the weight of stranded vs. solid wire?

A7: For a given AWG size, the weight difference between solid and stranded wire is generally negligible and not typically accounted for in standard weight estimations. The primary determinant is the cross-sectional area of the conductor metal.

Q8: What if my conduit length is very short, like just a few feet?

A8: The calculator works accurately for short lengths as well. The formulas are linear. You'll simply get a proportionally smaller weight, which is correct. For very short runs, the weight might be minimal, but it's still good practice to calculate.

Related Tools and Internal Resources

© 2023 Your Company Name. All rights reserved.

// Wire weight data (lbs/kft) – source: various electrical engineering handbooks // Includes standard allowances for insulation weight as well. var wireWeights = { "14": {"copper": 20.7, "aluminum": 6.6}, "12": {"copper": 32.5, "aluminum": 10.4}, "10": {"copper": 51.9, "aluminum": 16.5}, "8": {"copper": 82.0, "aluminum": 26.1}, "6": {"copper": 130.0, "aluminum": 41.4}, "4": {"copper": 205.0, "aluminum": 65.3}, "2": {"copper": 327.0, "aluminum": 104.0}, "1/0": {"copper": 413.0, "aluminum": 131.0}, "2/0": {"copper": 521.0, "aluminum": 165.0}, "3/0": {"copper": 655.0, "aluminum": 208.0}, "4/0": {"copper": 827.0, "aluminum": 263.0} }; // Conduit weight data (lbs/ft) – source: manufacturer data for common types/sizes // These are approximate and can vary. Using values for ~1″ diameter for simplicity here, // actual weight depends heavily on exact diameter and wall thickness. var conduitWeightsPerFt = { "emt": 0.63, "imc": 1.00, "rigid": 1.45, "pvc": 0.20 }; // Get DOM elements var conduitTypeSelect = document.getElementById("conduitType"); var conduitDiameterInput = document.getElementById("conduitDiameter"); var conduitLengthInput = document.getElementById("conduitLength"); var numberOfWiresInput = document.getElementById("numberOfWires"); var wireGaugeSelect = document.getElementById("wireGauge"); var wireMaterialSelect = document.getElementById("wireMaterial"); var wireInsulationSelect = document.getElementById("wireInsulationType"); var resultsContainer = document.getElementById("resultsContainer"); var primaryResultDiv = document.getElementById("primaryResult"); var conduitWeightResultSpan = document.getElementById("conduitWeightResult").getElementsByTagName("span")[0]; var wireWeightPerWireResultSpan = document.getElementById("wireWeightPerWireResult").getElementsByTagName("span")[0]; var totalWireWeightResultSpan = document.getElementById("totalWireWeightResult").getElementsByTagName("span")[0]; var tableConduitUnitWeightTd = document.getElementById("tableConduitUnitWeight"); var tableConduitQuantityTd = document.getElementById("tableConduitQuantity"); var tableConduitTotalWeightTd = document.getElementById("tableConduitTotalWeight"); var tableWireUnitWeightTd = document.getElementById("tableWireUnitWeight"); var tableWireQuantityTd = document.getElementById("tableWireQuantity"); var tableWireTotalWeightTd = document.getElementById("tableWireTotalWeight"); var chart; var chartContext; // Initialize chart function initChart() { chartContext = document.getElementById("weightChart").getContext("2d"); chart = new Chart(chartContext, { type: 'bar', data: { labels: ['Conduit Weight', 'Total Wire Weight'], datasets: [{ label: 'Estimated Weight (lbs)', data: [0, 0], backgroundColor: [ 'rgba(0, 74, 153, 0.7)', // Primary color for Conduit 'rgba(40, 167, 69, 0.7)' // Success color for Wires ], borderColor: [ 'rgba(0, 74, 153, 1)', 'rgba(40, 167, 69, 1)' ], borderWidth: 1 }] }, options: { responsive: true, maintainAspectRatio: false, scales: { y: { beginAtZero: true, ticks: { callback: function(value) { if (value % 10 === 0) { // Show ticks every 10 lbs return value + ' lbs'; } return null; // Don't show intermediate ticks } } } }, plugins: { legend: { display: false // Legend is implicitly shown by colors and labels }, title: { display: true, text: 'Weight Comparison: Conduit vs. Wires' } } } }); } // Update calculator and chart function updateCalculator() { if (!chart) { initChart(); } // Clear previous errors clearErrorMessages(); // Get input values var conduitType = conduitTypeSelect.value; var conduitDiameter = parseFloat(conduitDiameterInput.value); var conduitLength = parseFloat(conduitLengthInput.value); var numberOfWires = parseInt(numberOfWiresInput.value); var wireGauge = wireGaugeSelect.value; var wireMaterial = wireMaterialSelect.value; var wireInsulationType = wireInsulationSelect.value; // Not directly used in weight calculation but good for context // Get selected data attributes var conduitWeightPerFt = parseFloat(conduitTypeSelect.options[conduitTypeSelect.selectedIndex].getAttribute('data-weight')); var wireWeightPerKft = wireWeights[wireGauge] ? wireWeights[wireGauge][wireMaterial] : null; // — Validation — var isValid = true; if (isNaN(conduitDiameter) || conduitDiameter <= 0) { document.getElementById("conduitDiameterError").textContent = "Please enter a valid positive diameter."; isValid = false; } if (isNaN(conduitLength) || conduitLength <= 0) { document.getElementById("conduitLengthError").textContent = "Please enter a valid positive length."; isValid = false; } if (isNaN(numberOfWires) || numberOfWires <= 0) { document.getElementById("numberOfWiresError").textContent = "Please enter a valid number of wires (at least 1)."; isValid = false; } if (!wireWeightPerKft) { document.getElementById("wireGaugeError").textContent = "Invalid wire gauge selected."; isValid = false; } if (!isValid) { resultsContainer.style.display = 'none'; // Hide results if invalid if (chart) { chart.data.datasets[0].data = [0, 0]; chart.update(); } return; } // — Calculations — var conduitWeight = conduitWeightPerFt * conduitLength; var weightPerWire = (wireWeightPerKft / 1000) * conduitLength; var totalWireWeight = weightPerWire * numberOfWires; var totalWeight = conduitWeight + totalWireWeight; // — Update Results Display — primaryResultDiv.textContent = totalWeight.toFixed(2) + " lbs"; conduitWeightResultSpan.textContent = conduitWeight.toFixed(2) + " lbs"; wireWeightPerWireResultSpan.textContent = weightPerWire.toFixed(2) + " lbs"; totalWireWeightResultSpan.textContent = totalWireWeight.toFixed(2) + " lbs"; resultsContainer.style.display = 'block'; // — Update Table — tableConduitUnitWeightTd.textContent = conduitWeightPerFt.toFixed(2) + " lbs/ft"; tableConduitQuantityTd.textContent = conduitLength.toFixed(0) + " ft"; tableConduitTotalWeightTd.textContent = conduitWeight.toFixed(2) + " lbs"; tableWireUnitWeightTd.textContent = wireWeightPerKft.toFixed(1) + " lbs/kft (per conductor)"; tableWireQuantityTd.textContent = numberOfWires + " conductors"; tableWireTotalWeightTd.textContent = totalWireWeight.toFixed(2) + " lbs"; // — Update Chart — if (chart) { chart.data.datasets[0].data = [ parseFloat(conduitWeight.toFixed(2)), parseFloat(totalWireWeight.toFixed(2)) ]; chart.update(); } } function calculateWeight() { updateCalculator(); } function resetForm() { document.getElementById("conduitType").value = "emt"; document.getElementById("conduitDiameter").value = "1"; document.getElementById("conduitLength").value = "100"; document.getElementById("numberOfWires").value = "3"; document.getElementById("wireGauge").value = "14"; document.getElementById("wireMaterial").value = "copper"; document.getElementById("wireInsulationType").value = "thhn"; clearErrorMessages(); updateCalculator(); // Recalculate with defaults } function copyResults() { var conduitType = conduitTypeSelect.options[conduitTypeSelect.selectedIndex].text.split(' – ')[0]; var conduitDiameter = conduitDiameterInput.value; var conduitLength = conduitLengthInput.value; var numberOfWires = numberOfWiresInput.value; var wireGauge = wireGaugeSelect.value; var wireMaterial = wireMaterialSelect.value; var wireInsulationType = wireInsulationSelect.options[wireInsulationSelect.selectedIndex].text.split(' (')[0]; var conduitWeight = conduitWeightResultSpan.textContent; var wirePerWire = wireWeightPerWireResultSpan.textContent; var totalWireWeight = totalWireWeightResultSpan.textContent; var totalWeight = primaryResultDiv.textContent; var assumptions = "Assumptions:\n" + "- Conduit Type: " + conduitType + "\n" + "- Conduit Diameter: " + conduitDiameter + " in\n" + "- Conduit Length: " + conduitLength + " ft\n" + "- Number of Wires: " + numberOfWires + "\n" + "- Wire Gauge: " + wireGauge + " AWG\n" + "- Wire Material: " + wireMaterial + "\n" + "- Wire Insulation: " + wireInsulationType + "\n"; var resultsText = "— Conduit and Wire Weight Calculation Results —\n\n" + "Total Estimated Weight: " + totalWeight + "\n" + "Conduit Weight: " + conduitWeight + "\n" + "Weight Per Wire: " + wirePerWire + "\n" + "Total Wire Weight: " + totalWireWeight + "\n\n" + assumptions; // Use a temporary textarea to copy text var textArea = document.createElement("textarea"); textArea.value = resultsText; textArea.style.position = "fixed"; // Avoid scrolling to bottom textArea.style.left = "-9999px"; document.body.appendChild(textArea); textArea.focus(); textArea.select(); try { var successful = document.execCommand('copy'); var msg = successful ? 'Results copied to clipboard!' : 'Failed to copy results.'; // Optionally show a small notification console.log(msg); } catch (err) { console.error('Fallback: Oops, unable to copy', err); } document.body.removeChild(textArea); } function clearErrorMessages() { document.getElementById("conduitTypeError").textContent = ""; document.getElementById("conduitDiameterError").textContent = ""; document.getElementById("conduitLengthError").textContent = ""; document.getElementById("numberOfWiresError").textContent = ""; document.getElementById("wireGaugeError").textContent = ""; document.getElementById("wireMaterialError").textContent = ""; document.getElementById("wireInsulationTypeError").textContent = ""; } // Initialize calculation on page load window.onload = function() { updateCalculator(); // Initialize tooltips or other JS features if needed }; // Add functionality for FAQ accordions var faqItems = document.querySelectorAll('.faq-item h4'); for (var i = 0; i < faqItems.length; i++) { faqItems[i].addEventListener('click', function() { this.parentElement.classList.toggle('open'); }); }

Leave a Comment