How to Calculate UF Rate in Dialysis

Ultrafiltration (UF) is the process of removing excess fluid from the blood during hemodialysis. Calculating the correct UF rate is critical to ensure patient safety and prevent complications like hypotension, muscle cramps, or cardiovascular stress.

The UF Rate Formula

The calculation involves determining the total fluid volume that needs to be removed and dividing it by the treatment time:

1. Total Fluid (mL) = [(Pre-Weight – Dry Weight) × 1000] + Intake + Rinseback
2. UF Rate (mL/hr) = Total Fluid / Treatment Hours

Example Calculation

A patient has a pre-dialysis weight of 75 kg and a target dry weight of 73 kg. They plan to drink 200 mL of water during a 4-hour treatment, and the machine rinseback is 200 mL.

  • Weight difference: 75 – 73 = 2.0 kg (2000 mL)
  • Additional fluids: 200 mL (intake) + 200 mL (rinseback) = 400 mL
  • Total Goal: 2000 + 400 = 2400 mL
  • UF Rate: 2400 mL / 4 hours = 600 mL/hr

Safety Considerations

Clinical guidelines (KDOQI) often suggest that UF rates should generally not exceed 10 to 13 mL/kg/hr. Removing fluid faster than the body can refill the vascular space from the interstitial tissue can lead to sudden drops in blood pressure and organ ischemia.

function calculateUF() { var preWeight = parseFloat(document.getElementById('preWeight').value); var dryWeight = parseFloat(document.getElementById('dryWeight').value); var intake = parseFloat(document.getElementById('fluidIntake').value) || 0; var rinse = parseFloat(document.getElementById('rinseBack').value) || 0; var duration = parseFloat(document.getElementById('txDuration').value); var resultArea = document.getElementById('resultArea'); var totalGoalSpan = document.getElementById('totalGoal'); var ufRateSpan = document.getElementById('ufRateResult'); var safetyWarning = document.getElementById('safetyWarning'); if (isNaN(preWeight) || isNaN(dryWeight) || isNaN(duration) || duration maxSafeRate) { safetyWarning.innerHTML = "Caution: The calculated rate (" + ufRate.toFixed(0) + " mL/hr) exceeds the suggested safety threshold for this patient's dry weight (" + maxSafeRate.toFixed(0) + " mL/hr). Consult a physician regarding treatment duration or dry weight goals."; safetyWarning.style.display = 'block'; } else { safetyWarning.style.display = 'none'; } // Smooth scroll to result resultArea.scrollIntoView({ behavior: 'smooth', block: 'nearest' }); }