How to Calculate Vacuum Flow Rate

Vacuum Pump Flow Rate Calculator

Determine the required pumping speed for chamber evacuation

Atmospheric is ~760 Torr

Required Pumping Speed (S):

0 Liters/Minute (L/min)
0 Cubic Feet/Min (CFM)
0 m³/hour

Note: This calculation assumes an ideal system. For real-world applications, a safety factor of 1.5x to 2x is recommended to account for outgassing and conductance losses.

How to Calculate Vacuum Flow Rate

Calculating the vacuum flow rate (also known as pumping speed) is critical for sizing the correct vacuum pump for a specific chamber. If the flow rate is too low, you will never reach your target pressure within the required timeframe; if it is too high, you are overspending on equipment and energy.

The Basic Vacuum Evacuation Formula

The relationship between volume, time, pressure, and pumping speed is defined by the following physics equation:

S = (V / t) × ln(P1 / P2)

Where:

  • S: Pumping Speed (Flow Rate)
  • V: Total Volume of the system
  • t: Time required to reach the target pressure
  • P1: Starting pressure (usually atmospheric pressure)
  • P2: Final target vacuum pressure
  • ln: The natural logarithm

Example Calculation

Imagine you have a vacuum chamber with a volume of 100 Liters. You need to pull the pressure down from atmosphere (760 Torr) to a rough vacuum of 1 Torr within 2 minutes.

  1. Volume (V) = 100 L
  2. Time (t) = 2 min
  3. P1 / P2 = 760 / 1 = 760
  4. ln(760) ≈ 6.63
  5. S = (100 / 2) × 6.63 = 331.5 L/min

In this scenario, you would need a pump with a minimum effective flow rate of 331.5 L/min.

Factors Affecting Real-World Flow Rate

The calculator above provides the theoretical flow rate. In practical engineering, several factors reduce performance:

  • Conductance Losses: Narrow or long hoses between the pump and the chamber restrict flow.
  • Outgassing: Materials inside the chamber (plastics, adhesives) release gas molecules, effectively adding to the volume that needs to be pumped.
  • Leakage: Small leaks in seals or fittings introduce air back into the system.
  • Pump Curves: Pumping speed is not constant; most pumps lose efficiency as the pressure drops towards their ultimate limit.
function calculateVacuumFlow() { var v = parseFloat(document.getElementById('v_volume').value); var t = parseFloat(document.getElementById('v_time').value); var p1 = parseFloat(document.getElementById('v_p1').value); var p2 = parseFloat(document.getElementById('v_p2').value); var resultBox = document.getElementById('v_result_box'); // Validation if (isNaN(v) || isNaN(t) || isNaN(p1) || isNaN(p2) || v <= 0 || t <= 0 || p1 <= 0 || p2 = p1) { alert("Final pressure must be lower than initial pressure."); return; } // Calculation: S = (V/t) * ln(P1/P2) var ratio = p1 / p2; var lnRatio = Math.log(ratio); var flowLPM = (v / t) * lnRatio; // Unit conversions var flowCFM = flowLPM * 0.0353147; var flowM3H = flowLPM * 0.06; // Display Results document.getElementById('res_lpm').innerText = flowLPM.toFixed(2); document.getElementById('res_cfm').innerText = flowCFM.toFixed(2); document.getElementById('res_m3h').innerText = flowM3H.toFixed(2); resultBox.style.display = 'block'; }