Nec Load Calculation

NEC Load Calculation – Your Electrical Load Estimator :root { –primary-color: #004a99; –success-color: #28a745; –background-color: #f8f9fa; –text-color: #333; –border-color: #ddd; –shadow-color: rgba(0, 0, 0, 0.1); –card-background: #ffffff; –input-border: #ccc; } body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; line-height: 1.6; background-color: var(–background-color); color: var(–text-color); margin: 0; padding: 0; display: flex; flex-direction: column; align-items: center; padding-bottom: 50px; } .container { width: 100%; max-width: 960px; margin: 20px auto; padding: 25px; background-color: var(–card-background); border-radius: 8px; box-shadow: 0 4px 12px var(–shadow-color); display: flex; flex-direction: column; gap: 30px; } header { background-color: var(–primary-color); color: white; padding: 20px 0; text-align: center; width: 100%; } header h1 { margin: 0; font-size: 2.2em; font-weight: 600; } h2, h3 { color: var(–primary-color); border-bottom: 2px solid var(–primary-color); padding-bottom: 5px; margin-top: 25px; margin-bottom: 15px; font-weight: 600; } .calculator-section { display: flex; flex-direction: column; gap: 20px; } .loan-calc-container { display: flex; flex-direction: column; gap: 15px; padding: 20px; border: 1px solid var(–border-color); border-radius: 6px; background-color: #fdfdfd; } .input-group { display: flex; flex-direction: column; gap: 8px; } .input-group label { font-weight: bold; color: var(–primary-color); font-size: 0.95em; } .input-group input[type="number"], .input-group input[type="text"], .input-group select { padding: 10px 12px; border: 1px solid var(–input-border); border-radius: 4px; font-size: 1em; width: 100%; box-sizing: border-box; transition: border-color 0.3s ease; } .input-group input[type="number"]:focus, .input-group input[type="text"]:focus, .input-group select:focus { outline: none; border-color: var(–primary-color); box-shadow: 0 0 0 2px rgba(0, 74, 153, 0.2); } .input-group .helper-text { font-size: 0.85em; color: #666; margin-top: 5px; } .input-group .error-message { color: #dc3545; font-size: 0.8em; margin-top: 5px; height: 1.2em; visibility: hidden; } .input-group .error-message.visible { visibility: visible; } button { padding: 12px 20px; background-color: var(–primary-color); color: white; border: none; border-radius: 4px; font-size: 1em; cursor: pointer; transition: background-color 0.3s ease, transform 0.2s ease; margin-top: 5px; } button:hover { background-color: #003a7f; transform: translateY(-1px); } button.reset-button { background-color: #6c757d; } button.reset-button:hover { background-color: #5a6268; } button.copy-button { background-color: var(–success-color); margin-left: 10px; } button.copy-button:hover { background-color: #218838; } #results { background-color: var(–primary-color); color: white; padding: 20px; border-radius: 6px; margin-top: 20px; text-align: center; box-shadow: inset 0 2px 5px rgba(0,0,0,0.1); } #results h3 { color: white; border-bottom: 1px solid rgba(255, 255, 255, 0.5); margin-bottom: 15px; } .primary-result { font-size: 2.5em; font-weight: bold; margin-bottom: 10px; color: #ffc107; /* Accent color for primary result */ } .intermediate-results { display: flex; flex-wrap: wrap; justify-content: center; gap: 20px; margin-top: 15px; font-size: 0.9em; } .intermediate-results div { text-align: center; padding: 8px 12px; background-color: rgba(255, 255, 255, 0.15); border-radius: 4px; } .intermediate-results span { display: block; font-weight: bold; font-size: 1.2em; } #formula-explanation { margin-top: 15px; font-size: 0.9em; opacity: 0.8; } table { width: 100%; border-collapse: collapse; margin-top: 20px; box-shadow: 0 2px 6px var(–shadow-color); border-radius: 6px; overflow: hidden; } thead { background-color: var(–primary-color); color: white; } th, td { padding: 12px 15px; text-align: left; border: 1px solid var(–border-color); } th { font-weight: bold; } tbody tr:nth-child(even) { background-color: #f2f2f2; } caption { caption-side: top; text-align: left; font-weight: bold; color: var(–primary-color); margin-bottom: 10px; font-size: 1.1em; } canvas { display: block; margin: 20px auto; border: 1px solid var(–border-color); border-radius: 4px; background-color: var(–card-background); } .chart-legend { text-align: center; margin-top: 10px; font-size: 0.9em; } .chart-legend span { display: inline-block; margin: 0 15px; } .chart-legend div { display: inline-block; width: 15px; height: 15px; margin-right: 5px; vertical-align: middle; } .article-content { width: 100%; max-width: 960px; margin: 30px auto; padding: 25px; background-color: var(–card-background); border-radius: 8px; box-shadow: 0 4px 12px var(–shadow-color); text-align: left; } .article-content p { margin-bottom: 1.2em; } .article-content a { color: var(–primary-color); text-decoration: none; font-weight: 500; } .article-content a:hover { text-decoration: underline; } .article-content ul, .article-content ol { margin-left: 20px; margin-bottom: 1.2em; } .article-content li { margin-bottom: 0.5em; } .faq-item { margin-bottom: 15px; } .faq-item .question { font-weight: bold; color: var(–primary-color); cursor: pointer; display: flex; justify-content: space-between; align-items: center; padding: 8px 0; } .faq-item .question::after { content: '+'; font-size: 1.2em; transition: transform 0.3s ease; } .faq-item .question.active::after { transform: rotate(45deg); } .faq-item .answer { max-height: 0; overflow: hidden; transition: max-height 0.3s ease-out, padding 0.3s ease-out; padding: 0 0; color: #555; } .faq-item .answer.visible { max-height: 200px; /* Adjust as needed */ padding: 10px 0; } .related-tools ul { list-style: none; padding: 0; } .related-tools li { margin-bottom: 15px; padding-bottom: 10px; border-bottom: 1px dashed var(–border-color); } .related-tools li:last-child { border-bottom: none; } .related-tools span { display: block; font-size: 0.9em; color: #666; margin-top: 5px; } .sticky-results { position: sticky; top: 20px; align-self: start; /* Changed from center to start for sticky positioning */ width: 100%; /* Ensure it takes full width within its parent */ } @media (min-width: 768px) { .calculator-wrapper { display: flex; flex-direction: row; gap: 30px; } .calculator-section { flex: 1; min-width: 45%; /* Prevent it from shrinking too much */ } .sticky-results { width: 45%; /* Adjust width when alongside calculator */ flex-shrink: 0; /* Prevent shrinking */ align-self: flex-start; /* Ensure it sticks to the top */ } .container { gap: 0; /* Reset gap for the outer container if not needed with column layout */ } } @media (max-width: 767px) { .container { margin: 10px; padding: 15px; } header h1 { font-size: 1.8em; } .primary-result { font-size: 2em; } .sticky-results { position: static; /* Disable sticky on small screens */ order: -1; /* Move results to the top on mobile */ margin-bottom: 20px; } .calculator-wrapper { flex-direction: column; } }

NEC Load Calculation – Electrical Load Estimator

NEC Load Calculation Inputs

Single-Phase (120/240V) Three-Phase (120/208V) Three-Phase (277/480V)
Select the voltage system for your service.
The main breaker or fuse rating of the electrical service.
For multi-family dwellings, enter the number of separate living units.
Typical circuits for general lighting and receptacles.
Required for specific areas like kitchens, bathrooms, and laundry rooms.
Enter the count for circuits rated at 240V.
Sum of watts for large appliances not on standard circuits (e.g., electric water heater, oven).

Calculated NEC Load

Demand Load (A)
Subtotal Amps
Service Size (A)
Standard Load
Demand Load
Load Calculation Breakdown
Load Type Quantity Amperage per Circuit Total Amperage Demand Factor Demand Amps

{primary_keyword} is a critical process for ensuring electrical systems are designed and installed safely and efficiently according to the National Electrical Code (NEC). It involves calculating the anticipated electrical load a building or circuit will draw to determine the appropriate size for the electrical service, feeders, branch circuits, and protective devices. Proper load calculation is fundamental to preventing overloads, fires, and equipment damage. This estimation helps electricians, engineers, and inspectors ensure compliance with safety standards and allows for future expansion of electrical systems.

What is NEC Load Calculation?

NEC load calculation refers to the method specified in Article 220 of the National Electrical Code (NEC) used to determine the minimum electrical demand load for wiring systems, service-entrance conductors, and service equipment. It's not simply adding up the maximum capacity of every circuit; instead, it applies various demand factors and multipliers based on the type of occupancy and the nature of the loads. This allows for a more realistic assessment of the electrical system's needs, recognizing that not all connected loads will operate simultaneously at their maximum capacity.

Who should use it:

  • Electricians and Electrical Contractors: Essential for planning and installing new electrical services and systems, ensuring code compliance.
  • Electrical Engineers: Used in the design phase of buildings and electrical infrastructure to specify appropriate service sizes and components.
  • Homeowners undertaking major renovations: Useful for understanding electrical capacity needs when adding significant new appliances or living spaces.
  • Inspectors: To verify that installations meet NEC requirements for safety and capacity.

Common misconceptions:

  • "Just add up all the breaker sizes": This is a common mistake. The NEC uses demand factors, recognizing that not all loads run at full capacity simultaneously.
  • "It's only for new construction": Load calculations are often required for service upgrades, additions, or significant changes to existing systems.
  • "Demand factors are always conservative": While they aim for realism, improper application can lead to undersized systems or non-compliance.

NEC Load Calculation Formula and Mathematical Explanation

The NEC load calculation is a multi-step process, primarily detailed in NEC Article 220. The specific steps and demand factors vary based on the type of installation (residential, commercial, industrial) and the specific loads involved. For a typical dwelling unit, the calculation involves determining the general lighting load and the small-appliance/laundry loads, then applying demand factors. Larger appliances and HVAC equipment are calculated separately.

General Lighting and Small Appliance Load (Dwelling Units)

This is often the first major component calculated for residential services.

Formula:

  1. Calculate Base Load: (Number of Dwelling Units * 3 VA/sq ft * Square Footage per unit) + (Number of Small Appliance Branch Circuits * 1500 VA/circuit) + (Number of Laundry Circuits * 1500 VA/circuit)
  2. Apply Demand Factors: The first 3000 VA is calculated at 100%. The remaining load is calculated at 35%.
  3. Convert to Amps: Divide the calculated VA by the system voltage (e.g., 240V for single-phase).

Appliance Load

Individual appliance loads are calculated, often with specific NEC rules for ranges, dryers, and other fixed appliances. For this simplified calculator, we'll sum specific high-wattage appliances.

Formula:

  1. Sum Wattage: Add the wattage of specific high-wattage appliances.
  2. Apply Demand Factors (if applicable): NEC Article 220 provides specific demand factors for ranges and other appliances based on their rating and number. For simplicity here, we often treat larger appliances as their nameplate wattage or a calculated value.
  3. Convert to Amps: Divide the VA by the system voltage.

Other Loads

Circuits for HVAC, water heaters, motors, and other specific equipment are added, often without demand factors unless specifically allowed by the NEC. Standard circuit loads are often calculated at 1500 VA (120V * 15A) or 2400 VA (120V * 20A) or 240V * circuit breaker rating.

Total Calculated Load

All calculated loads (lighting, small appliance, appliance, HVAC) are summed to find the total calculated load in Amperes.

Simplified Calculator Logic (as implemented above):

  1. Calculate Base General Load: (Number of 15A circuits * 120V * 15A) + (Number of 20A circuits * 120V * 20A) + (Number of 240V circuits * calculated VA per 240V circuit). For simplicity, we often assume 1500 VA for 15A/120V, 2400 VA for 20A/120V, and a calculated VA for 240V circuits.
  2. Calculate Dwelling Unit Adjustment (NEC 220.42): For dwelling units, the first 3000 VA is at 100%, the remainder at 35%. This is applied to the general lighting and small appliance loads.
  3. Add Specific Appliances: Add the wattage of specific high-wattage appliances.
  4. Add Other Loads: Add loads for 240V appliances/circuits.
  5. Sum All Loads: Total calculated load in VA = (Adjusted General/Small Appliance Load) + (Specific Appliance Load) + (Other Loads).
  6. Convert to Amps: Total Amps = Total VA / Service Voltage.
  7. Demand Load Calculation: The calculator applies NEC-style demand factors to portions of the load to arrive at a more realistic demand amperage. For this calculator, we simplify: (Number of 15A circuits * 15A) + (Number of 20A circuits * 20A) + (Number of 240V circuits * breaker rating) + (Specific appliance amps). Then apply a simplified demand factor (e.g., 75% for loads over 10kW). The specific demand factor applied here is illustrative.
  8. Final Service Size: The calculated demand load is compared to the service amperage rating. The NEC often requires the service size to be at least the calculated load, plus potentially 125% of the continuous loads. For simplicity, we show the calculated demand load and compare it to the service rating.

Variables Table

Variables Used in Simplified NEC Load Calculation
Variable Meaning Unit Typical Range/Value
Service Type Voltage configuration of the electrical service. Type Single-Phase (120/240V), Three-Phase (120/208V, 277/480V)
Total Service Amperage Rating The maximum current capacity of the main service breaker/fuse. Amperes (A) 100, 200, 400, 600+
Num Dwelling Units Number of individual residential living spaces. Count 1+
Num 15A, 120V Circuits Number of standard 15-amp, 120-volt branch circuits. Count 0+
Num 20A, 120V Circuits Number of 20-amp, 120-volt branch circuits for specific outlets. Count 0+
Num 240V Circuits Number of 240-volt branch circuits for major appliances. Count 0+
Specific Appliance Watts Total wattage of major fixed appliances. Watts (W) 0+
Calculated Load (VA) Total apparent power demand before demand factors. Volt-Amperes (VA) Varies
Demand Load (A) Adjusted load amperage after applying NEC demand factors. Amperes (A) Varies
Service Size (A) The minimum required rating for the main service conductors and equipment. Amperes (A) Matches or exceeds Demand Load

Practical Examples (Real-World Use Cases)

Example 1: Standard Single-Family Home

Scenario: A typical single-family home with a 200-amp, 120/240V service. It has 15 general lighting/receptacle circuits, 6 kitchen/laundry 20A circuits, 2 dedicated 240V circuits (electric dryer, electric oven), and a 4000W electric water heater.

Inputs:

  • Service Type: 120/240V
  • Total Service Amperage Rating: 200 A
  • Number of Dwelling Units: 1
  • Number of 15A, 120V Circuits: 15
  • Number of 20A, 120V Circuits: 6
  • Number of 240V Circuits: 2
  • Specific Appliance Watts: 4000 W (Electric Water Heater)

Calculation Breakdown (Simplified):

  • 15 x 15A = 225A (120V circuits)
  • 6 x 20A = 120A (20A circuits)
  • 2 x 240V circuits (assume 30A each for dryer/oven) = 60A
  • Water Heater: 4000W / 240V = ~16.7A
  • Total Amps (without demand factors initially): 225 + 120 + 60 + 16.7 = 421.7A (This shows why demand factors are crucial!)
  • The calculator will apply NEC demand factors. For instance, general lighting/small appliance load might be calculated based on square footage and then adjusted. A simplified demand factor might be applied to the total calculated load.

Calculator Output (Illustrative):

  • Demand Load: ~165 A
  • Subtotal Amps: ~165 A
  • Service Size: 200 A

Interpretation: The calculated demand load of 165A is well within the 200A service capacity, indicating the 200A service is adequately sized for this home's expected usage, assuming standard NEC demand factors are applied correctly. This confirms the electrical system is safe and can handle the connected appliances.

Example 2: Small Multi-Unit Apartment Building

Scenario: A small building with 4 apartment units, each served by a main 100A, 120/240V sub-panel. The building has a single 400A, 120/240V main service. Each unit has typical loads: 10 x 15A circuits, 4 x 20A circuits, 1 x 240V range (8000W), 1 x 240V dryer (4500W).

Inputs (for one unit, then multiplied):

  • Service Type: 120/240V
  • Total Service Amperage Rating: 100 A (for sub-panel perspective)
  • Number of Dwelling Units: 1 (calculating per unit first)
  • Number of 15A, 120V Circuits: 10
  • Number of 20A, 120V Circuits: 4
  • Number of 240V Circuits: 2 (Range, Dryer)
  • Specific Appliance Watts: 0 W (Assuming Range/Dryer watts are handled by 240V circuit calculation)

Calculation Breakdown (Per Unit, Simplified):

  • 10 x 15A = 150A
  • 4 x 20A = 80A
  • Range (8000W): 8000W / 240V = 33.3A
  • Dryer (4500W): 4500W / 240V = 18.75A
  • The NEC has specific rules for calculating loads for multiple dwelling units, often involving demand factors for kitchens, laundry, and general lighting based on the number of units.
  • Let's assume the calculator determines a demand load of approx. 70A per unit after applying NEC rules.

Total Building Load:

  • Calculated Demand Load per Unit: ~70 A
  • Total Demand Load for 4 Units: 4 units * 70 A/unit = 280 A

Calculator Output (for the Main Service):

  • Demand Load: ~280 A
  • Subtotal Amps: ~280 A
  • Service Size: 400 A

Interpretation: A 400A main service is calculated to be sufficient for the 4-unit building, with a demand load of approximately 280A. This ensures the main service conductors and equipment can safely handle the aggregate, yet diversified, electrical demand of all units operating concurrently under expected conditions. This calculation is vital for ensuring the overall building infrastructure is robust and compliant, preventing common electrical issues in multi-unit dwellings.

How to Use This NEC Load Calculation Calculator

Our NEC Load Calculation tool simplifies the process of estimating your electrical system's demand. Follow these steps for an accurate assessment:

  1. Select Service Type: Choose the voltage and phase configuration of your main electrical service (e.g., 120/240V Single-Phase for most homes).
  2. Enter Service Amperage Rating: Input the rating of your main circuit breaker or fuse (e.g., 100A, 200A). This is the total capacity available.
  3. Specify Dwelling Units: If calculating for a multi-unit dwelling, enter the total number of separate living units. For a single-family home, enter '1'.
  4. Input Circuit Counts: Accurately count the number of each type of branch circuit:
    • 15A, 120V circuits (general lighting, outlets)
    • 20A, 120V circuits (kitchen small appliances, laundry, bathroom)
    • 240V circuits (electric ranges, dryers, ovens, water heaters, large HVAC units)
  5. Add Specific Appliance Watts: Sum the wattage ratings (from the nameplate) of any major fixed appliances that don't have their own dedicated 240V circuit count, or that have exceptionally high power draw (e.g., electric furnaces, large water heaters).
  6. View Results: The calculator will automatically update the "Demand Load," "Subtotal Amps," and the recommended "Service Size."
  7. Interpret the Output:
    • Demand Load (A): This is the calculated maximum current your system is expected to draw, after applying NEC demand factors.
    • Subtotal Amps: In this simplified model, it often matches the Demand Load.
    • Service Size (A): This represents the minimum required rating for your main service conductors and equipment based on the calculated demand load. Ensure your actual installed service rating is equal to or greater than this value.
  8. Use the Table and Chart: The table breaks down how each input contributes to the total load, and the chart visually represents the distribution of loads.
  9. Copy Results: Use the "Copy Results" button to save or share your calculation summary, including key assumptions.
  10. Reset: Click "Reset" to clear current inputs and return to default values.

Decision-Making Guidance: If your calculated "Service Size" is greater than your current "Total Service Amperage Rating," it indicates you likely need a service upgrade. This ensures safety and prevents nuisance tripping of your main breaker. Always consult with a qualified electrician for final design and installation.

Key Factors That Affect NEC Load Calculation Results

Several factors influence the outcome of an NEC load calculation, impacting the required service size and overall electrical system design. Understanding these can help in accurately using the calculator and interpreting results:

  1. Type of Occupancy: Residential, commercial, and industrial settings have vastly different load profiles and thus different NEC calculation methods and demand factors. A home's load differs significantly from a factory or an office building.
  2. Connected Load (Total Amperage/Wattage): The sum of all potential loads is the starting point. More circuits, higher wattage appliances, and larger HVAC systems naturally increase the calculated load. This is the most direct input.
  3. Demand Factors: These are multipliers specified by the NEC that reduce the calculated load. They are based on the statistical improbability that all connected loads will operate at maximum capacity simultaneously. Applying the correct demand factors is crucial for accurate sizing and avoids oversizing, which can be costly. For example, NEC 220.42 applies demand factors to general lighting and small appliance loads in dwelling units.
  4. Voltage and Phase System: The available voltage (120V, 240V, 208V, 480V) and phase configuration (single-phase, three-phase) directly affect the amperage calculation (Amps = Watts / Volts for single-phase, or Amps = Watts / (Volts * √3) for three-phase). Three-phase systems are generally more efficient for larger commercial loads.
  5. Continuous vs. Non-Continuous Loads: The NEC requires conductors and overcurrent protection devices to be sized at 125% of the continuous load (loads expected to operate for 3 hours or more) plus 100% of the non-continuous load. This detail is often simplified in basic calculators but is critical for professional design.
  6. Future Expansion Considerations: While the NEC specifies minimum requirements, it's wise to consider future needs. Planning for additional circuits or a potential service upgrade can save significant costs and effort later. Some electrical professionals advise slightly oversizing the initial service based on anticipated growth, though this must still align with NEC principles.
  7. Harmonics and Non-Linear Loads: Modern electronic equipment (computers, LEDs, variable frequency drives) can introduce harmonic currents, which increase the effective current and heat in conductors and transformers. Standard NEC calculations might not fully account for these, potentially requiring specialized analysis for large commercial/industrial facilities.
  8. Specific NEC Article Requirements: Different sections of the NEC address specific types of loads (e.g., ranges, dryers, HVAC, electric vehicle charging stations, swimming pools) with unique calculation rules and demand factors. Our calculator uses a simplified approach for these.

Frequently Asked Questions (FAQ)

What is the difference between Connected Load and Demand Load?
Connected Load is the sum of the ratings of all electrical equipment connected to a system. Demand Load is the maximum load expected to be served by the system at any one time, taking into account the likelihood of simultaneous operation (using demand factors). The demand load is typically less than the connected load.
Does the NEC require load calculations for service upgrades?
Yes, NEC Article 220 generally requires load calculations for any new electrical service or service upgrade to ensure the new service is adequately sized for the connected load, including applicable demand factors.
How does the number of dwelling units affect the load calculation?
For multiple dwelling units, the NEC applies specific demand factors to reduce the total calculated load. For example, larger loads like kitchens and laundry circuits may have different demand factors applied based on the number of units, reflecting that not all units will use these heavily at the same time.
What is a VA (Volt-Ampere) and why is it used?
VA represents apparent power, which is the product of voltage and current (V x A). It's used in AC circuits because it accounts for both real power (Watts, doing actual work) and reactive power (required by inductive or capacitive components). For resistive loads like simple heating elements, VA is equal to Watts. For most electrical calculations, especially AC, VA is the foundational unit before applying power factors or demand factors.
Can I just use my main breaker size as the required service size?
No. Your main breaker size is the *available* capacity. The NEC load calculation determines the *required minimum* capacity. Your actual service size must be equal to or greater than the calculated demand load (plus considerations for continuous loads). If your calculated load exceeds your current breaker size, an upgrade is necessary.
What are typical demand factors for residential services?
For dwelling units, NEC 220.42 specifies demand factors for the general lighting, small-appliance, and laundry loads. The first 3000 VA is calculated at 100%, and the remainder is calculated at 35%. Specific appliances like ranges also have their own demand factors based on size and quantity per NEC 220.55.
Is this calculator a substitute for professional electrical design?
This calculator provides an estimate based on common NEC principles and simplified rules. It is intended for informational purposes and should not replace a detailed load calculation performed by a qualified electrician or engineer, especially for complex installations, commercial buildings, or critical systems. Always adhere to local codes and consult professionals.
What happens if my calculated load exceeds my service rating?
If your calculated demand load exceeds your current main service amperage rating, it indicates your service is undersized for the connected load. This poses a safety risk, potentially leading to overloaded wiring, overheating, and fire hazards. You will likely need to upgrade your electrical service to a higher amperage rating.
How do electric vehicle (EV) charging loads factor in?
EV charging is considered a continuous load by the NEC. Dedicated circuits for EV chargers must be sized at 125% of the charger's rating. When calculating the total service load, the EV charger circuit's demand (often 125% of its rated amperage) is added to the overall calculation, potentially requiring a larger service size. This calculator simplifies this by treating it under general or 240V circuits, but professional calculations must account for NEC 625.
// — Helper Functions — function validateInput(id, min, max) { var input = document.getElementById(id); var errorElement = document.getElementById(id + 'Error'); var value = parseFloat(input.value); errorElement.textContent = "; errorElement.classList.remove('visible'); input.style.borderColor = '#ccc'; if (isNaN(value)) { errorElement.textContent = 'Please enter a valid number.'; errorElement.classList.add('visible'); input.style.borderColor = '#dc3545'; return false; } if (value max) { errorElement.textContent = 'Value is too high.'; errorElement.classList.add('visible'); input.style.borderColor = '#dc3545'; return false; } return true; } function getInputValue(id, defaultValue) { var input = document.getElementById(id); var value = parseFloat(input.value); return isNaN(value) ? defaultValue : value; } function setResults(demandAmps, subTotalAmps, serviceSize, assumptions) { document.getElementById('primaryResult').textContent = demandAmps.toFixed(1) + ' A'; document.getElementById('demandLoadAmps').querySelector('span').textContent = demandAmps.toFixed(1); document.getElementById('subTotalAmps').querySelector('span').textContent = subTotalAmps.toFixed(1); document.getElementById('serviceSizeAmps').querySelector('span').textContent = serviceSize.toFixed(0); document.getElementById('keyAssumptions').textContent = "Assumptions: " + assumptions; } function updateFormulaExplanation(text) { document.getElementById('formula-explanation').textContent = text; } function updateLoadTable(data) { var tableBody = document.getElementById('loadTableBody'); tableBody.innerHTML = "; // Clear existing rows var voltage = parseFloat(document.getElementById('serviceType').value.split('/')[1]); if (isNaN(voltage)) voltage = 240; // Default to 240V if split fails var totalLoadVA = 0; var standardLoadAmps = 0; var demandLoadAmps = 0; // Add rows for calculated loads data.forEach(function(item) { var row = tableBody.insertRow(); row.insertCell(0).textContent = item.type; row.insertCell(1).textContent = item.quantity; row.insertCell(2).textContent = item.ampsPerCircuit ? item.ampsPerCircuit.toFixed(1) : '-'; var totalCircuitAmps = item.quantity * (item.ampsPerCircuit || 0); row.insertCell(3).textContent = totalCircuitAmps.toFixed(1); var demandFactor = item.demandFactor || 1.0; // Default to 100% if not specified row.insertCell(4).textContent = demandFactor === 1.0 ? '100%' : (demandFactor * 100).toFixed(0) + '%'; var demandCircuitAmps = totalCircuitAmps * demandFactor; row.insertCell(5).textContent = demandCircuitAmps.toFixed(1); totalLoadVA += demandCircuitAmps * voltage; // Use demand amps * voltage for total VA standardLoadAmps += totalCircuitAmps; // Sum of actual circuit amperages demandLoadAmps += demandCircuitAmps; // Sum of demand amperages if (item.type.includes("Lighting") || item.type.includes("Small Appliance")) { // Mark these for potential demand factor application later if needed } }); // Add a row for specific appliances if they exist var specificApplianceWatts = getInputValue('specificApplianceWatts', 0); if (specificApplianceWatts > 0) { var applianceAmps = specificApplianceWatts / voltage; // Simplified: assume 100% demand for this calculator's specific appliance calculation unless NEC states otherwise var applianceDemandFactor = 1.0; var demandApplianceAmps = applianceAmps * applianceDemandFactor; var row = tableBody.insertRow(); row.insertCell(0).textContent = "Specific High-Wattage Appliances"; row.insertCell(1).textContent = "1"; // Represents the aggregate row.insertCell(2).textContent = '-'; row.insertCell(3).textContent = applianceAmps.toFixed(1); row.insertCell(4).textContent = applianceDemandFactor === 1.0 ? '100%' : (applianceDemandFactor * 100).toFixed(0) + '%'; row.insertCell(5).textContent = demandApplianceAmps.toFixed(1); totalLoadVA += demandApplianceAmps * voltage; demandLoadAmps += demandApplianceAmps; } // Recalculate totals based on final demand amps var finalDemandLoadAmps = demandLoadAmps; // Apply a global demand factor if needed (simplified approach) // NEC 220.42 covers dwelling units: first 3000 VA at 100%, remainder at 35%. // Let's apply this logic conceptually here. var serviceVoltage = getInputValue('serviceType', '120/240').includes('240') ? 240 : 120; // Use 240V for single phase, need to be careful with 3 phase if(document.getElementById('serviceType').value === '120/208') serviceVoltage = 208; if(document.getElementById('serviceType').value === '277/480') serviceVoltage = 480; var lightingAndSmallApplianceAmps = 0; var otherLoadsAmps = 0; data.forEach(function(item) { if (item.type.includes("Lighting") || item.type.includes("Small Appliance")) { lightingAndSmallApplianceAmps += item.quantity * (item.ampsPerCircuit || 0); } else { otherLoadsAmps += item.quantity * (item.ampsPerCircuit || 0) * (item.demandFactor || 1.0); // Apply demand factor if already defined for these } }); if (specificApplianceWatts > 0) { otherLoadsAmps += (specificApplianceWatts / serviceVoltage) * 1.0; // Assume 100% demand factor for specific appliances for simplicity here } var lightingAndSmallApplianceVA = lightingAndSmallApplianceAmps * serviceVoltage; var adjustedLightingAndSmallApplianceVA = Math.min(lightingAndSmallApplianceVA, 3000) + Math.max(0, lightingAndSmallApplianceVA – 3000) * 0.35; var adjustedLightingAndSmallApplianceAmps = adjustedLightingAndSmallApplianceVA / serviceVoltage; finalDemandLoadAmps = adjustedLightingAndSmallApplianceAmps + otherLoadsAmps; // Ensure finalDemandLoadAmps isn't lower than the sum of individual demands if the above calculation yields less finalDemandLoadAmps = Math.max(finalDemandLoadAmps, demandLoadAmps); // Ensure demand load is at least the sum of the amperage for the 240V circuits and specific appliances, as these are often not subject to the same demand factors as general lighting. var minimumDemandBase = 0; data.forEach(function(item){ if (item.type.includes('240V') || item.type.includes('Appliance')) { minimumDemandBase += item.quantity * (item.ampsPerCircuit || 0) * (item.demandFactor || 1.0); } }); if (specificApplianceWatts > 0) { minimumDemandBase += (specificApplianceWatts / serviceVoltage) * 1.0; // Assume 100% demand factor } finalDemandLoadAmps = Math.max(finalDemandLoadAmps, minimumDemandBase); // Adjust calculation for 3-phase var serviceType = document.getElementById('serviceType').value; var phaseMultiplier = (serviceType.startsWith('3')) ? Math.sqrt(3) : 1; // Recalculate based on phase var totalAmperageRating = getInputValue('totalAmperage', 200); var numDwellingUnits = getInputValue('numDwellingUnits', 1); var num120V15A = getInputValue('num120V15A', 10); var num120V20A = getInputValue('num120V20A', 5); var num240V = getInputValue('num240V', 3); var specificApplianceWatts = getInputValue('specificApplianceWatts', 3000); var calculatedDemandAmps = 0; var subTotalAmpsValue = 0; var loadDataForTable = []; var lightingLoadAmps = 0; var smallApplianceLoadAmps = 0; var laundryLoadAmps = 0; var applianceLoadAmps = 0; var specificApplianceLoadAmps = 0; // Based on NEC 220 Part III for Dwelling Units (Simplified) // Step 1: Calculate loads as per 220.40, 220.41 var generalLightingVA = (numDwellingUnits * 3 * 1500); // Assuming 1500 sq ft per unit as a baseline, NEC 220.42 requires sq ft. Using 3VA/sqft * 1500 sqft. var applianceCircuitLoadVA = (num120V20A * 1500) + (num120V15A * 1500) + (num240V * 2400); // Simplified: assuming 2400VA for each 240V circuit for calculation base. // Sum specific appliance watts and convert to VA var specificApplianceVA = specificApplianceWatts; // Assuming watts given are already VA or power factor is 1. // NEC 220.42 Demand Factors for Lighting / Small Appliances var first3000VA = Math.min(generalLightingVA + applianceCircuitLoadVA, 3000); // Simplified: combining general and small appliance for 3000VA base. var remainingVA = Math.max(0, (generalLightingVA + applianceCircuitLoadVA) – 3000); var adjustedGeneralLoadVA = first3000VA + (remainingVA * 0.35); // Convert to amps var serviceVoltage = 240; // Default for 120/240V if (serviceType === '120/208') serviceVoltage = 208; if (serviceType === '277/480') serviceVoltage = 480; var adjustedGeneralLoadAmps = adjustedGeneralLoadVA / serviceVoltage; // Add other loads (240V circuits, specific appliances) – often without demand factors unless NEC specifies var otherLoadsAmpsTotal = 0; if (num240V > 0) { var volts240 = 240; // Standard voltage for these calculations var ampsPer240V = 30; // Assuming typical 30A for ranges/dryers; NEC Table 220.55 has specific factors for ranges > 12kW if (serviceType === '120/208') volts240 = 208; // Use system voltage if (serviceType === '277/480') volts240 = 480; // A more robust calculation would sum individual 240V appliances and apply NEC 220.55 for ranges. // Simplified: Sum amperage directly and then potentially apply a demand factor. var total240VA = num240V * ampsPer240V * volts240; // Simplified base VA var demandFactor240 = 1.0; // Default, but NEC 220.55 has complex factors for multiple ranges. // Let's use the direct input amperage for 240V circuits for clarity in the table var ampsFor240Circuit = 30; // Assume 30A for typical 240V appliance circuits like dryer/oven var totalAmpsFrom240Circuits = num240V * ampsFor240Circuit; otherLoadsAmpsTotal += totalAmpsFrom240Circuits; // Add to the sum of calculated amps loadDataForTable.push({ type: "240V Appliance Circuits", quantity: num240V, ampsPerCircuit: ampsFor240Circuit, demandFactor: demandFactor240 }); } if (specificApplianceWatts > 0) { var specificApplianceAmps = specificApplianceWatts / serviceVoltage; var demandFactorSpecificAppliance = 1.0; // Assume 100% demand for simplicity here otherLoadsAmpsTotal += specificApplianceAmps * demandFactorSpecificAppliance; specificApplianceLoadAmps = specificApplianceAmps; // Store for table loadDataForTable.push({ type: "Specific High-Wattage Appliances", quantity: 1, ampsPerCircuit: null, demandFactor: demandFactorSpecificAppliance }); // Qty 1 represents the sum } // Add lighting and small appliance circuits to table data if (num120V15A > 0) loadDataForTable.push({ type: "15A, 120V Circuits (General)", quantity: num120V15A, ampsPerCircuit: 15, demandFactor: 1.0 }); if (num120V20A > 0) loadDataForTable.push({ type: "20A, 120V Circuits (Small App/Laundry)", quantity: num120V20A, ampsPerCircuit: 20, demandFactor: 1.0 }); // Calculate demand load based on NEC methodology var calculatedDemandAmpsFinal = 0; var subTotalAmpsValueFinal = 0; // Lighting/Small Appliance Demand Calculation (NEC 220.42) var totalLightingSmallApplianceAmps = (num120V15A * 15) + (num120V20A * 20); // Base amps var totalLightingSmallApplianceVA = totalLightingSmallApplianceAmps * serviceVoltage; var adjustedLightingSmallApplianceVA = Math.min(totalLightingSmallApplianceVA, 3000) + Math.max(0, totalLightingSmallApplianceVA – 3000) * 0.35; var demandLoadFromLightingSmallAppliance = adjustedLightingSmallApplianceVA / serviceVoltage; // Sum other loads (240V circuits, specific appliances) var demandLoadFromOther = 0; if (num240V > 0) { var ampsPer240Circuit = 30; // Default assumption demandLoadFromOther += num240V * ampsPer240Circuit; // Typically treated at 100% unless specific NEC rules apply (e.g. ranges > 12kW) loadDataForTable.find(item => item.type.includes("240V")).ampsPerCircuit = ampsPer240Circuit; // Update table if found } if (specificApplianceWatts > 0) { demandLoadFromOther += (specificApplianceWatts / serviceVoltage); // Assume 100% demand factor for specific appliance watts input loadDataForTable.find(item => item.type.includes("Specific High-Wattage")).ampsPerCircuit = (specificApplianceWatts / serviceVoltage).toFixed(1); // Update table } calculatedDemandAmpsFinal = demandLoadFromLightingSmallAppliance + demandLoadFromOther; subTotalAmpsValueFinal = calculatedDemandAmpsFinal; // For this simplified calc, subtotal is the demand load // Apply 125% rule for continuous loads if applicable (Simplified) // This calculator doesn't explicitly identify continuous loads, so we'll skip this complex step for now. // Compare to service rating var serviceSizeAmps = Math.max(totalAmperageRating, calculatedDemandAmpsFinal); // Minimum service size is the calculated demand load // Adjust for 3-phase loads – standard calculation often assumes single phase unless explicitly for 3-phase loads if (serviceType.startsWith('3')) { // For 3-phase, the VA calculation and amp conversion differ. // The calculator inputs are simplified. For a true 3-phase calc, VA = sqrt(3) * V_line * I_line // Amps = VA / (sqrt(3) * V_line) // This simplified calculator's inputs primarily model single-phase dwelling units. // We'll adjust the final output conceptually. The inputs (15A, 20A, 240V) are more typical of single-phase residential. // For 3-phase, loads are usually specified in VA or kW directly. // Let's assume the user is modelling a single-phase load within a 3-phase system, or the inputs are representative. // If it was truly a 3-phase load calculation, inputs would be different (e.g., kW, VA per phase). // Simple adjustment: If it's 3-phase, the demand load might be higher relative to the same VA. // However, the core calculation methodology here is geared towards residential single-phase. // Let's keep the amps calculation as is but note the limitation. // A common practice for 3-phase is to sum VA and then divide by (Voltage_Line_to_Line * sqrt(3)). // Since our inputs are Amps, we'll proceed with Amp sums. } // Final checks and table updates updateLoadTable(loadDataForTable); // Use the generated loadDataForTable setResults(calculatedDemandAmpsFinal, subTotalAmpsValueFinal, serviceSizeAmps, "Based on simplified NEC Article 220 methodology for dwelling units. Demand factors applied."); updateChart(calculatedDemandAmpsFinal, demandLoadFromOther, serviceVoltage, serviceType.startsWith('3')); } function updateChart(demandLoad, otherLoadsAmps, voltage, isThreePhase) { var ctx = document.getElementById('loadChart').getContext('2d'); if (window.myChart) { window.myChart.destroy(); } var totalLoadAmps = demandLoad; // Use the final calculated demand load // Calculate the components represented in the table for the chart var lightingSmallApplianceDemand = 0; var otherLoadsDemand = 0; var tableRows = document.getElementById('loadTableBody').rows; for (var i = 0; i 0.1) { // Adjust if there's a slight difference due to rounding // Rebalance if necessary, or use the primary calculated value for total // For simplicity, let's ensure the chart reflects the main calculated demand load by adjusting one component if needed. // Or better, ensure the calculation logic feeding the table IS the one used for the main result. // Assuming `totalLoadAmps` is the definitive calculated demand load: otherLoadsDemand = totalLoadAmps – lightingSmallApplianceDemand; // Re-calculate other loads demand based on main result if (otherLoadsDemand < 0) otherLoadsDemand = 0; // Ensure non-negative lightingSmallApplianceDemand = totalLoadAmps – otherLoadsDemand; if (lightingSmallApplianceDemand serviceRating; var maxDisplayValue = Math.max(totalLoadAmps, serviceRating) * 1.1; // Extend y-axis slightly beyond max if (overLimit) { // Adjust dataset data to show overload visually if needed, or just scale Y axis chartData.datasets[0].data = [lightingSmallApplianceDemand]; chartData.datasets[1].data = [otherLoadsDemand]; maxDisplayValue = totalLoadAmps * 1.1; // Scale based on actual demand if overloaded } window.myChart = new Chart(ctx, { type: 'bar', data: chartData, options: { responsive: true, maintainAspectRatio: false, scales: { y: { beginAtZero: true, title: { display: true, labelString: 'Amperes (A)' }, max: maxDisplayValue // Auto scales based on data } }, plugins: { title: { display: true, text: 'Demand Load Breakdown by Component' }, legend: { display: false // Using custom legend below } } } }); } function calculateNECLoad() { // Validate inputs first var isValid = true; isValid = validateInput('totalAmperage', 0) && isValid; isValid = validateInput('numDwellingUnits', 0) && isValid; isValid = validateInput('num120V15A', 0) && isValid; isValid = validateInput('num120V20A', 0) && isValid; isValid = validateInput('num240V', 0) && isValid; isValid = validateInput('specificApplianceWatts', 0) && isValid; if (!isValid) { // Clear results if inputs are invalid setResults('–', '–', '–', 'Please correct errors.'); updateLoadTable([]); // Clear table updateChart(0, 0, 240, false); // Clear chart updateFormulaExplanation("Invalid inputs detected. Please correct errors."); return; } var serviceType = document.getElementById('serviceType').value; var totalAmperageRating = getInputValue('totalAmperage', 200); var numDwellingUnits = getInputValue('numDwellingUnits', 1); var num120V15A = getInputValue('num120V15A', 10); var num120V20A = getInputValue('num120V20A', 5); var num240V = getInputValue('num240V', 3); var specificApplianceWatts = getInputValue('specificApplianceWatts', 3000); var serviceVoltage = 240; // Default for 120/240V if (serviceType === '120/208') serviceVoltage = 208; if (serviceType === '277/480') serviceVoltage = 480; // — Core Calculation Logic (Simplified NEC Article 220 for Dwelling Units) — // This is a simplified implementation. Real NEC calculations are complex and have many nuances. // Step 1: Calculate Base Loads in VA // General lighting load based on square footage is often used, but not provided. We'll use VA/circuit as a proxy. // NEC 220.42: Lighting load = 3 VA per square foot. For this calculator, we approximate based on circuit count. // Let's assume 1500 VA per 15A/120V circuit and 1500 VA per 20A/120V circuit for general calculation base, // and a base VA for 240V circuits before specific appliance watts. var baseLightingSmallApplianceVA = (num120V15A * 1500) + (num120V20A * 1500); // Base VA for general / small appliance circuits var base240VApplianceVA = num240V * 2400; // Assume 2400 VA base for each 240V circuit (e.g., 10A @ 240V) var specificApplianceVA = specificApplianceWatts; // Watts provided is treated as VA // Combine general/small appliance loads for demand factor application var combinedLightingApplianceVA = baseLightingSmallApplianceVA; // Step 2: Apply Demand Factors (NEC 220.42 for Dwelling Units) var demandLoadVA = 0; var lightingDemandFactor = 1.0; // Default var applianceDemandFactor = 1.0; // Default var first3000VA = Math.min(combinedLightingApplianceVA, 3000); var remainingVA = Math.max(0, combinedLightingApplianceVA – 3000); var adjustedLightingApplianceVA = first3000VA + (remainingVA * 0.35); // Step 3: Calculate Amperage for each component var demandLoadAmps = 0; var subTotalAmpsValue = 0; var loadBreakdown = []; // For table // Lighting & Small Appliance Demand Amps var lightingSmallApplianceDemandAmps = adjustedLightingApplianceVA / serviceVoltage; demandLoadAmps += lightingSmallApplianceDemandAmps; loadBreakdown.push({ type: "Lighting & Small Appliance", quantity: num120V15A + num120V20A, ampsPerCircuit: 15, demandFactor: 0.35 }); // Representing the calculated demand aspect // 240V Appliance Loads if (num240V > 0) { var typical240VAmp = 30; // Assume typical 30A breaker for common 240V appliances like dryer/oven // NEC 220.55 has specific demand factors for ranges based on size and quantity. // For simplicity, we'll sum the amperage and potentially apply a demand factor. // Let's calculate the raw amps first for the table. var raw240Amps = num240V * typical240VAmp; loadBreakdown.push({ type: "240V Appliance Circuits", quantity: num240V, ampsPerCircuit: typical240VAmp, demandFactor: 1.0 }); // Show base amps // Add to demand load – assuming 100% demand for simplicity here, unless NEC demands otherwise. // Real NEC would apply factors from Table 220.55. Let's use raw amps for demand calculation for now. demandLoadAmps += raw240Amps; } // Specific High-Wattage Appliance Loads if (specificApplianceWatts > 0) { var specificApplianceAmps = specificApplianceWatts / serviceVoltage; // Assume 100% demand factor for specific appliances not covered by other rules. demandLoadAmps += specificApplianceAmps; loadBreakdown.push({ type: "Specific High-Wattage Appliances", quantity: 1, ampsPerCircuit: specificApplianceAmps.toFixed(1), demandFactor: 1.0 }); } subTotalAmpsValue = demandLoadAmps; // In this simplified model, subtotal is the calculated demand load // Final Service Size Calculation // The service size must be sufficient for the calculated demand load. // NEC also requires 125% of continuous loads. This calculator simplifies this. var requiredServiceSize = Math.max(totalAmperageRating, demandLoadAmps); // Update table and results display updateFormulaExplanation("Calculated demand load based on simplified NEC Article 220 methodology for dwelling units, applying demand factors to lighting and small appliance loads."); var finalLoadBreakdown = []; // Populate table with calculated values and correct demand factors // Lighting/Small Appliance var totalBaseLightingApplianceAmps = (num120V15A * 15) + (num120V20A * 20); var totalBaseLightingApplianceVA = totalBaseLightingApplianceAmps * serviceVoltage; var adjVA_LS = Math.min(totalBaseLightingApplianceVA, 3000) + Math.max(0, totalBaseLightingApplianceVA – 3000) * 0.35; var demandLS_Amps = adjVA_LS / serviceVoltage; finalLoadBreakdown.push({ type: "Lighting & Small Appliance", quantity: num120V15A + num120V20A, ampsPerCircuit: null, demandFactor: 0.35 }); // Indicate demand factor applied // 240V Appliances var total240DemandAmps = 0; if (num240V > 0) { var typical240VAmp = 30; total240DemandAmps = num240V * typical240VAmp; // Assuming 100% demand factor for simplicity finalLoadBreakdown.push({ type: "240V Appliance Circuits", quantity: num240V, ampsPerCircuit: typical240VAmp, demandFactor: 1.0 }); } // Specific Appliances var specificApplianceDemandAmps = 0; if (specificApplianceWatts > 0) { specificApplianceDemandAmps = specificApplianceWatts / serviceVoltage; // Assuming 100% demand factor finalLoadBreakdown.push({ type: "Specific High-Wattage Appliances", quantity: 1, ampsPerCircuit: specificApplianceDemandAmps.toFixed(1), demandFactor: 1.0 }); } // Recalculate final demand load sum var finalDemandLoad = demandLS_Amps + total240DemandAmps + specificApplianceDemandAmps; var finalSubTotal = finalDemandLoad; var finalServiceSize = Math.max(totalAmperageRating, finalDemandLoad); updateLoadTable(finalLoadBreakdown); // Update table with calculated data setResults(finalDemandLoad, finalSubTotal, finalServiceSize, "Based on simplified NEC Article 220 dwelling unit calculations."); updateChart(finalDemandLoad, total240DemandAmps + specificApplianceDemandAmps, serviceVoltage, serviceType.startsWith('3')); // Pass other loads component for chart } function resetCalculator() { document.getElementById('serviceType').value = '120/240'; document.getElementById('totalAmperage').value = '200'; document.getElementById('numDwellingUnits').value = '1'; document.getElementById('num120V15A').value = '10'; document.getElementById('num120V20A').value = '5'; document.getElementById('num240V').value = '3'; document.getElementById('specificApplianceWatts').value = '3000'; // Clear error messages var errorElements = document.querySelectorAll('.error-message'); errorElements.forEach(function(el) { el.textContent = "; el.classList.remove('visible'); }); var inputs = document.querySelectorAll('.input-group input, .input-group select'); inputs.forEach(function(input) { input.style.borderColor = '#ccc'; }); calculateNECLoad(); // Recalculate with default values } function copyResults() { var primaryResult = document.getElementById('primaryResult').textContent; var demandLoad = document.getElementById('demandLoadAmps').querySelector('span').textContent; var subTotalAmps = document.getElementById('subTotalAmps').querySelector('span').textContent; var serviceSize = document.getElementById('serviceSizeAmps').querySelector('span').textContent; var assumptions = document.getElementById('keyAssumptions').textContent; var table = document.getElementById('loadTableBody'); var tableContent = "Load Calculation Breakdown:\n"; tableContent += "————————————————–\n"; tableContent += "Load Type | Qty | Amps/Circuit | Total Amps | Demand Factor | Demand Amps\n"; tableContent += "————————————————–\n"; for (var i = 0; i < table.rows.length; i++) { var row = table.rows[i]; var cells = row.cells; tableContent += `${cells[0].textContent.padEnd(30)} | ${cells[1].textContent.padEnd(3)} | ${cells[2].textContent.padEnd(12)} | ${cells[3].textContent.padEnd(10)} | ${cells[4].textContent.padEnd(13)} | ${cells[5].textContent}\n`; } tableContent += "————————————————–\n"; var chartInfo = "Chart data represents breakdown of Demand Load components.\n"; var textToCopy = `— NEC Load Calculation Results —\n\n`; textToCopy += `Primary Result (Required Service Size): ${primaryResult}\n`; textToCopy += `Calculated Demand Load: ${demandLoad}\n`; textToCopy += `Subtotal Amps: ${subTotalAmps}\n\n`; textToCopy += `${assumptions}\n\n`; textToCopy += `${tableContent}\n`; textToCopy += `${chartInfo}\n`; navigator.clipboard.writeText(textToCopy).then(function() { alert('Results copied to clipboard!'); }, function(err) { console.error('Failed to copy: ', err); alert('Failed to copy results. Please copy manually.'); }); } // Initialize calculator on page load window.onload = function() { calculateNECLoad(); setupFAQ(); }; // Chart.js initialization (needs to be defined if not already present globally) // Placeholder if Chart.js is intended to be used externally. For pure native, this would be SVG/Canvas draw logic. // Since we are using Canvas, we need Chart.js or direct Canvas API drawing. // Assuming Chart.js is available via CDN or local include. For this example, we'll assume it's available. // If not, we'd need to draw bars directly onto canvas using its 2D API. // For a self-contained HTML, we'll rely on the native Canvas API without Chart.js. // —- REPLACING Chart.js logic with native Canvas API —- function updateChart(demandLoad, otherLoadsAmps, voltage, isThreePhase) { var canvas = document.getElementById('loadChart'); var ctx = canvas.getContext('2d'); canvas.height = 250; // Set a fixed height for the canvas ctx.clearRect(0, 0, canvas.width, canvas.height); // Clear previous drawings var serviceRating = getInputValue('totalAmperage', 200); var totalDemand = demandLoad; // Using the calculated final demand load var lightingSmallApplianceDemand = 0; var otherLoadsDemand = 0; // Retrieve data from the table to accurately represent chart components var tableRows = document.getElementById('loadTableBody').rows; for (var i = 0; i 0.1) { // Adjust components if they don't sum correctly to the main result // Prioritize the main result's accuracy. If lighting/SA is calculated and matches table, adjust others. otherLoadsDemand = totalDemand – lightingSmallApplianceDemand; if (otherLoadsDemand < 0) otherLoadsDemand = 0; // Ensure non-negative lightingSmallApplianceDemand = totalLoadAmps – otherLoadsDemand; // Recalculate lighting/SA based on total if (lightingSmallApplianceDemand < 0) lightingSmallApplianceDemand = 0; } var maxVal = Math.max(totalDemand, serviceRating) * 1.15; // Scale Y-axis var barWidth = 50; var gapWidth = 20; var chartHeight = canvas.height – 60; // Padding at bottom var chartWidth = canvas.width – 60; // Padding at sides var xStart = (canvas.width – (barWidth * 2 + gapWidth)) / 2; // Draw Y-axis and labels ctx.beginPath(); ctx.moveTo(xStart, 20); ctx.lineTo(xStart, canvas.height – 40); ctx.strokeStyle = '#ccc'; ctx.stroke(); // Draw labels for Y-axis var numLabels = 5; for (var i = 0; i serviceRating) { var serviceRatingY = canvas.height – 40 – (serviceRating / maxVal) * chartHeight; ctx.beginPath(); ctx.moveTo(xStart – 10, serviceRatingY); ctx.lineTo(xStart + barWidth * 2 + gapWidth + 10, serviceRatingY); ctx.setLineDash([5, 5]); ctx.strokeStyle = '#dc3545'; // Red for overload ctx.stroke(); ctx.setLineDash([]); // Reset dash ctx.fillStyle = '#dc3545'; ctx.textAlign = 'left'; ctx.fillText('Service Rating: ' + serviceRating + ' A (Undersized)', xStart + barWidth * 2 + gapWidth + 15, serviceRatingY); } else { // Indicate current service rating if not overloaded var serviceRatingY = canvas.height – 40 – (serviceRating / maxVal) * chartHeight; ctx.beginPath(); ctx.moveTo(xStart – 10, serviceRatingY); ctx.lineTo(xStart + barWidth * 2 + gapWidth + 10, serviceRatingY); ctx.setLineDash([2, 2]); ctx.strokeStyle = '#6c757d'; // Gray for reference ctx.stroke(); ctx.setLineDash([]); // Reset dash ctx.fillStyle = '#6c757d'; ctx.textAlign = 'left'; ctx.fillText('Service Rating: ' + serviceRating + ' A', xStart + barWidth * 2 + gapWidth + 15, serviceRatingY); } // Update legend document.querySelector('.chart-legend .span:nth-of-type(1) div').style.backgroundColor = '#004a99'; document.querySelector('.chart-legend .span:nth-of-type(2) div').style.backgroundColor = '#28a745'; } function setupFAQ() { var questions = document.querySelectorAll('.faq-item .question'); questions.forEach(function(q) { q.addEventListener('click', function() { var answer = this.nextElementSibling; this.classList.toggle('active'); if (answer.style.maxHeight) { answer.style.maxHeight = null; answer.style.paddingBottom = '0'; } else { // Set max-height to the scroll height to ensure it fits content answer.style.maxHeight = answer.scrollHeight + "px"; answer.style.paddingBottom = '10px'; // Add some padding when open } }); }); }

Leave a Comment