Seer Rating Calculator

SEER Rating Calculator & Guide :root { –primary-color: #004a99; –success-color: #28a745; –background-color: #f8f9fa; –text-color: #333; –border-color: #ddd; –card-background: #fff; –shadow: 0 2px 5px rgba(0,0,0,.1); } body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; line-height: 1.6; color: var(–text-color); background-color: var(–background-color); margin: 0; padding: 20px; } .container { max-width: 1000px; margin: 0 auto; background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: var(–shadow); } h1, h2, h3 { color: var(–primary-color); margin-bottom: 15px; } h1 { text-align: center; margin-bottom: 30px; } .calculator-section { background-color: var(–card-background); padding: 25px; border-radius: 8px; box-shadow: var(–shadow); margin-bottom: 30px; } .loan-calc-container { display: flex; flex-direction: column; gap: 20px; } .input-group { display: flex; flex-direction: column; gap: 8px; } .input-group label { font-weight: bold; color: var(–primary-color); } .input-group input, .input-group select { padding: 12px; border: 1px solid var(–border-color); border-radius: 4px; font-size: 1rem; box-sizing: border-box; /* Include padding and border in the element's total width and height */ } .input-group input:focus, .input-group select:focus { outline: none; border-color: var(–primary-color); box-shadow: 0 0 0 3px rgba(0, 74, 153, 0.2); } .helper-text { font-size: 0.85rem; color: #666; margin-top: 4px; } .error-message { color: red; font-size: 0.8rem; margin-top: 4px; min-height: 1.2em; /* Prevent layout shifts */ } .button-group { display: flex; gap: 10px; margin-top: 25px; flex-wrap: wrap; /* Allow wrapping on smaller screens */ } .btn { padding: 12px 20px; border: none; border-radius: 5px; font-size: 1rem; cursor: pointer; font-weight: bold; transition: background-color 0.3s ease, transform 0.2s ease; white-space: nowrap; /* Prevent button text wrapping */ } .btn-primary { background-color: var(–primary-color); color: white; } .btn-primary:hover { background-color: #003f80; transform: translateY(-1px); } .btn-secondary { background-color: #6c757d; color: white; } .btn-secondary:hover { background-color: #5a6268; transform: translateY(-1px); } .btn-reset { background-color: #ffc107; color: #212529; } .btn-reset:hover { background-color: #e0a800; transform: translateY(-1px); } .results-container { margin-top: 30px; padding: 20px; border: 1px dashed var(–border-color); border-radius: 6px; background-color: var(–background-color); } .results-container h3 { margin-top: 0; color: var(–primary-color); text-align: center; } #primary-result { font-size: 2.5rem; font-weight: bold; color: var(–success-color); text-align: center; margin-bottom: 20px; padding: 15px; background-color: #e9f7ef; border-radius: 5px; } .intermediate-results div, .formula-explanation { margin-bottom: 15px; font-size: 1rem; } .intermediate-results span, .formula-explanation span { font-weight: bold; color: var(–primary-color); } .chart-container { margin-top: 30px; padding: 20px; background-color: var(–card-background); border-radius: 8px; box-shadow: var(–shadow); text-align: center; } canvas { max-width: 100%; height: auto; } .chart-caption { font-size: 0.9rem; color: #666; margin-top: 10px; display: block; } .table-container { margin-top: 30px; overflow-x: auto; /* For responsiveness */ } table { width: 100%; border-collapse: collapse; margin-top: 15px; box-shadow: var(–shadow); } th, td { padding: 12px 15px; text-align: left; border: 1px solid var(–border-color); } thead th { background-color: var(–primary-color); color: white; font-weight: bold; } tbody tr:nth-child(even) { background-color: #f2f2f2; } .table-caption { font-size: 0.9rem; color: #666; margin-bottom: 10px; display: block; text-align: center; } .article-content { margin-top: 40px; background-color: var(–card-background); padding: 30px; border-radius: 8px; box-shadow: var(–shadow); } .article-content h2 { border-bottom: 2px solid var(–primary-color); padding-bottom: 5px; margin-top: 25px; } .article-content h3 { margin-top: 20px; color: #0056b3; } .article-content p, .article-content ul, .article-content ol { margin-bottom: 15px; } .article-content ul, .article-content ol { padding-left: 20px; } .article-content li { margin-bottom: 8px; } .faq-list { list-style: none; padding: 0; } .faq-item { border: 1px solid var(–border-color); border-radius: 5px; margin-bottom: 15px; } .faq-question { background-color: #e7f3ff; padding: 15px; font-weight: bold; color: var(–primary-color); cursor: pointer; border-radius: 5px 5px 0 0; position: relative; } .faq-question::after { content: '+'; position: absolute; right: 15px; font-size: 1.2rem; } .faq-question.active::after { content: '-'; } .faq-answer { padding: 15px; display: none; /* Hidden by default */ border-top: 1px solid var(–border-color); background-color: var(–card-background); border-radius: 0 0 5px 5px; } .internal-links-list { list-style: none; padding: 0; } .internal-links-list li { margin-bottom: 10px; } .internal-links-list a { color: var(–primary-color); text-decoration: none; font-weight: bold; } .internal-links-list a:hover { text-decoration: underline; } .internal-links-list span { display: block; font-size: 0.9rem; color: #555; margin-top: 4px; } .variable-table { width: 100%; border-collapse: collapse; margin-top: 15px; } .variable-table th, .variable-table td { padding: 10px; text-align: left; border: 1px solid var(–border-color); } .variable-table th { background-color: #e7f3ff; color: var(–primary-color); font-weight: bold; } @media (min-width: 768px) { .button-group { justify-content: flex-end; } }

SEER Rating Calculator

HVAC Efficiency Calculator

Enter the total cooling capacity of your system in BTU/hr.
Enter the total energy consumed by the system over a cooling season in Watt-hours (Wh).

Your System's SEER Rating

Formula: SEER = Total Cooling Output (BTU) / Total Energy Input (Watt-hours) * 3.412

Seasonal Energy Consumption vs. SEER Rating

Comparison of estimated seasonal energy consumption for different SEER ratings based on your cooling capacity.

SEER Rating Standards and Benefits

Overview of SEER ratings, minimum standards, and potential benefits.
SEER Rating Energy Efficiency Level Potential Savings (vs. 10 SEER) Compliance
Below 13 Below Standard / Inefficient N/A Non-compliant (in many regions)
13 – 14.5 Minimum Standard / Basic Efficiency 0% – 12% Minimum Compliant
14.5 – 16 Good Efficiency 12% – 25% Above Minimum
16 – 18 Very Good Efficiency 25% – 35% High Efficiency
18+ Exceptional Efficiency 35%+ ENERGY STAR® / Premium Efficiency

What is SEER Rating?

The SEER rating, which stands for Seasonal Energy Efficiency Ratio, is a standardized measure of an air conditioner's or air-source heat pump's cooling efficiency. It represents the cooling output of a central air conditioner during a typical cooling season divided by the total electric energy input during the same period. Essentially, a higher SEER rating indicates a more energy-efficient system. This metric is crucial for homeowners and building managers looking to understand their HVAC system's performance and its impact on energy bills and environmental footprint.

Who should use a SEER rating calculator? Anyone considering purchasing a new air conditioning system, replacing an old unit, or simply wanting to understand the efficiency of their current system should use a SEER rating calculator. It's particularly useful for comparing different models and making informed decisions about which system best balances upfront cost with long-term energy savings. Homeowners in regions with high cooling demands will see the most significant financial benefits from higher SEER-rated units.

Common misconceptions about SEER ratings: One common misconception is that a higher SEER unit always means drastically lower bills, regardless of climate or usage. While efficiency is key, actual savings depend on factors like thermostat settings, insulation, ductwork, and local electricity rates. Another is that SEER is the only efficiency metric; Energy Efficiency Ratio (EER) is also important for peak load conditions, and HSPF (Heating Seasonal Performance Factor) measures heating efficiency for heat pumps. Finally, assuming all SEER ratings are directly comparable without considering manufacturer-specific performance data can be misleading.

SEER Rating Formula and Mathematical Explanation

The SEER rating is calculated by dividing the total cooling output of an air conditioning unit over a typical cooling season by the total energy consumed during that same period. The standard formula, adjusted for common units, is:

SEER = (Total Cooling Output in BTU) / (Total Energy Input in Watt-hours) * 3.412

Let's break down the components:

  • Total Cooling Output (BTU): This is the amount of heat the air conditioner removes from your home over a cooling season. It's typically measured in British Thermal Units (BTU). For calculations, we often use the system's rated capacity (e.g., 36,000 BTU/hr for a 3-ton unit) and multiply it by the estimated number of hours the system runs per season.
  • Total Energy Input (Watt-hours): This is the total amount of electricity the air conditioner consumes to produce that cooling output over the season. It's measured in Watt-hours (Wh).
  • 3.412 Conversion Factor: This factor is used to convert Watt-hours (electrical energy) into BTUs (thermal energy). One Watt is approximately 3.412 BTU per hour. Multiplying the energy input in Wh by this factor helps us compare apples to apples – thermal output versus thermal equivalent of electrical input.

The resulting SEER number is a ratio, indicating how many BTUs of cooling are produced for each watt-hour of electricity consumed. A higher SEER value means more efficient cooling – the system delivers more cooling for the same amount of energy, or the same amount of cooling for less energy.

Variables Table

Variable Meaning Unit Typical Range
SEER Seasonal Energy Efficiency Ratio BTU/Wh 13 – 26+
Cooling Capacity Total heat removal capacity of the AC unit. BTU/hr 12,000 – 60,000+ (1 to 5+ tons)
Seasonal Energy Input Total electricity consumed by the AC unit over a cooling season. Watt-hours (Wh) 1,000 – 15,000+ (highly variable)
Seasonal Cooling Output Total heat removed over a cooling season. BTU 200,000 – 1,000,000+ (depends on climate & usage)
Conversion Factor Converts electrical energy to thermal energy equivalent. BTU/Wh 3.412 (Constant)

Practical Examples (Real-World Use Cases)

Example 1: Comparing Two Systems

Sarah is looking to replace her old air conditioner. She's considering two options:

  • System A: A 3-ton (36,000 BTU/hr) unit with a SEER rating of 14.
  • System B: A 3-ton (36,000 BTU/hr) unit with a SEER rating of 18.
She estimates her current system runs for approximately 2000 hours per cooling season and consumes about 2500 kWh (2,500,000 Wh) per season.

Calculation for System A (SEER 14): Assuming System A operates at its SEER rating, its energy consumption would be roughly: Total Energy Input = (Total Cooling Output) / SEER Total Cooling Output = 36,000 BTU/hr * 2000 hrs = 72,000,000 BTU Estimated Energy Input (Wh) = 72,000,000 BTU / 14 = 5,142,857 Wh Estimated Energy Input (kWh) = 5,142,857 Wh / 1000 = 5,143 kWh

Calculation for System B (SEER 18): Estimated Energy Input (Wh) = 72,000,000 BTU / 18 = 4,000,000 Wh Estimated Energy Input (kWh) = 4,000,000 Wh / 1000 = 4,000 kWh

Interpretation: System B, with its higher SEER rating, is estimated to consume approximately 1,143 kWh less electricity per season (5,143 kWh – 4,000 kWh). If Sarah pays $0.15 per kWh, this translates to annual savings of about $171.45 (1,143 kWh * $0.15). Over the lifespan of the unit, the higher upfront cost of System B could be offset by significant energy savings, making it a more financially sound choice long-term. This calculation highlights the importance of assessing energy usage in any SEER rating calculator analysis.

Example 2: Evaluating Current System Efficiency

John has a 2.5-ton (30,000 BTU/hr) air conditioner. Over the last cooling season, his electricity bills show that the AC unit consumed approximately 3,200 kWh (3,200,000 Wh). He wants to know its SEER rating.

First, we need the estimated total cooling output. Assuming a typical cooling season of 1800 operating hours for his region: Total Cooling Output (BTU) = 30,000 BTU/hr * 1800 hrs = 54,000,000 BTU

Now, using the SEER formula: SEER = (54,000,000 BTU) / (3,200,000 Wh) * 3.412 SEER = 16.875 * 3.412 SEER ≈ 57.6 (This seems exceptionally high and indicates an issue with input data or assumptions, highlighting the need for accurate measurements or typical ranges).

Correction & Re-evaluation: The calculation above resulted in an unusually high SEER. This often happens because "Total Energy Input" in the SEER formula is usually derived from *rated* efficiency, not actual measured consumption in a specific season, which can vary wildly. A more realistic approach to checking a current system's SEER often relies on manufacturer specs or professional evaluation. However, if we *must* use actual measured energy consumption to infer a "seasonal efficiency ratio," it's better to compare it directly to industry benchmarks. A SEER of 14 is a common minimum. If John's system consumes 3,200 kWh for 30,000 BTU/hr capacity, let's see what SEER this *implies* if the system were running optimally.

Let's reverse the formula to find the SEER if the energy input was indeed 3200 kWh, assuming the cooling output is fixed at 54,000,000 BTU: SEER = Total Cooling Output (BTU) / Total Energy Input (Wh) * 3.412 SEER = 54,000,000 BTU / 3,200,000 Wh * 3.412 SEER = 16.875 * 3.412 ≈ 57.6 This still yields an impractical number. The issue is that actual energy consumption includes factors beyond just the SEER rating (e.g., inverter efficiency, fan motor usage, thermostat cycling, installation quality, duct leakage).

Revised Interpretation: A more practical way to interpret actual energy use is to compare it to the expected consumption of a *known* SEER system. If a 30,000 BTU/hr system is operating at SEER 14, it would consume approx: Energy (Wh) = 54,000,000 BTU / 14 * 3.412 ≈ 13,165,028 Wh ≈ 13,165 kWh (This is extremely high, suggesting the initial 1800 hours assumption might be off, or the system is very inefficient). Let's try a 16 SEER system: Energy (Wh) = 54,000,000 BTU / 16 * 3.412 ≈ 11,560,500 Wh ≈ 11,561 kWh If John's system used 3,200 kWh, it implies it is performing *much better* than typical SEER 14 or SEER 16 systems *for the number of hours it ran*. This could mean: 1. The system is indeed highly efficient (high SEER). 2. The system ran for significantly fewer hours than assumed. 3. The "cooling output" calculation is inaccurate for his specific usage patterns. This example demonstrates how a seer rating calculator can help identify discrepancies and prompt further investigation into HVAC performance and energy usage.

How to Use This SEER Rating Calculator

Using our SEER rating calculator is straightforward and designed to provide quick insights into your HVAC system's efficiency. Follow these steps:

  1. Locate Your System's Cooling Capacity: This is usually found on the unit's nameplate or in your system's documentation. It's typically measured in BTU/hr. Common sizes are 18,000 BTU/hr (1.5 tons), 24,000 BTU/hr (2 tons), 36,000 BTU/hr (3 tons), etc. Enter this value into the "Cooling Capacity" field.
  2. Determine Seasonal Energy Input: This is the most challenging part for existing systems. Ideally, you'd find the total kilowatt-hours (kWh) your air conditioner consumed over an entire cooling season (e.g., from May to September). You might be able to estimate this by looking at your electricity bills, subtracting baseline usage (non-cooling months), or using a smart meter/energy monitor if available. If you are evaluating a new system, this value will be based on the manufacturer's specifications for a given SEER rating under standard test conditions. Enter this value in Watt-hours (Wh) into the "Seasonal Energy Input" field. 1 kWh = 1000 Wh.
  3. View Your SEER Rating: Once both values are entered, the calculator will instantly display your system's calculated SEER rating in the "Primary Result" section.
  4. Analyze Intermediate Values: The calculator also shows the total seasonal cooling output in BTU and the energy input in both Wh and kWh for context.
  5. Interpret the Results: Compare your calculated SEER rating against the industry standards table provided. A rating below 13 may indicate an older, inefficient unit that could be costly to run. Ratings of 14.5 and above are generally considered efficient. Use this information to decide if upgrading your system is financially justifiable.
  6. Use the Chart and Table: The dynamic chart visually compares how different SEER ratings might affect your energy consumption based on your system's cooling capacity. The table provides a quick reference for SEER standards and potential savings.
  7. Copy Results: Use the "Copy Results" button to save or share your calculated SEER rating, intermediate values, and key assumptions for future reference.
  8. Reset: Click "Reset" to clear all fields and start fresh.

This tool is an excellent first step in understanding your HVAC efficiency and making informed decisions about potential upgrades. Remember that actual energy savings can vary based on installation quality, climate, and personal usage habits, making precise SEER calculation complex.

Key Factors That Affect SEER Rating Results

While the SEER rating itself is a standardized metric, the *actual performance* and *energy savings* achieved by an HVAC system are influenced by numerous factors beyond the number on the label. Understanding these is crucial for realistic expectations:

  1. Climate and Geographic Location: SEER is a seasonal average. In extremely hot climates where the AC runs for many hours daily, a higher SEER rating will yield more significant savings than in milder climates. The total number of cooling hours is a primary driver of overall energy consumption.
  2. Thermostat Settings and Usage Habits: Setting the thermostat significantly lower than the outside temperature increases the workload and energy consumption. Frequent adjustments or allowing the temperature to rise dramatically between cooling cycles can also impact efficiency and the effectiveness of a high SEER unit.
  3. Installation Quality: This is paramount. A high SEER unit installed improperly (e.g., incorrect refrigerant charge, undersized or oversized unit for the home, poor duct connections) will never perform to its rated SEER. Professional installation ensures optimal performance.
  4. Ductwork Integrity: Leaky or poorly insulated ductwork can account for a substantial loss of cooled air before it reaches living spaces (up to 30% in some homes). Even a high SEER system will struggle to cool effectively and efficiently if conditioned air escapes through duct leaks.
  5. Home Insulation and Air Sealing: The better your home retains cool air, the less work your AC has to do. A well-insulated and air-sealed home reduces heat gain, allowing a high SEER system to maintain comfort with less energy usage. Conversely, a poorly sealed home negates much of the benefit of an efficient AC.
  6. System Maintenance: Regular maintenance, such as cleaning or replacing air filters, cleaning outdoor coils, and ensuring proper airflow, is essential for maintaining peak efficiency. Neglected systems perform poorly and consume more energy. A clogged filter, for instance, restricts airflow, making the system work harder.
  7. Age and Condition of Existing Unit: Older AC units, even if they had a decent SEER rating when new, degrade over time. Components wear out, efficiency drops, and performance diminishes. This calculator helps compare potential upgrades against the likely performance of an aging system.
  8. Local Electricity Rates: While not affecting the SEER rating itself, the cost of electricity ($/kWh) directly determines the dollar amount of energy savings achieved by a higher SEER system. Areas with high electricity prices see faster payback periods for efficient upgrades.

Frequently Asked Questions (FAQ)

  • What is the minimum SEER rating required by law?
    The minimum SEER rating varies by region and has increased over time. Currently, in the northern United States, the minimum is 13 SEER. In the southern and southwestern US, it's 14 SEER (as of 2023). These standards are set by the Department of Energy (DOE) and are subject to change. Always check your local regulations.
  • How is SEER calculated for a new installation?
    For new installations, the SEER rating is determined by the manufacturer based on rigorous testing protocols established by AHRI (Air-Conditioning, Heating, and Refrigeration Institute). The rating reflects performance under specific simulated seasonal conditions. Our SEER calculator tool uses this principle to estimate what a given unit *should* achieve based on its rated capacity and energy input.
  • Can I calculate SEER if I only know my AC's tonnage?
    Knowing the tonnage (which relates to BTU/hr cooling capacity) is only half the equation. You also need the energy consumption (in Watt-hours or kWh) over the cooling season to calculate SEER. Tonnage tells you the cooling *potential*, while energy consumption tells you how efficiently that potential is realized.
  • What's the difference between SEER, EER, and HSPF?
    SEER (Seasonal Energy Efficiency Ratio) measures cooling efficiency over an entire cooling season, considering varying temperatures. EER (Energy Efficiency Ratio) measures efficiency at a single, peak outdoor temperature (usually 95°F). HSPF (Heating Seasonal Performance Factor) measures the heating efficiency of heat pumps. They are all important metrics, but SEER is the standard for overall cooling season efficiency.
  • Is a 14.5 SEER system much better than a 13 SEER system?
    Yes, the difference is noticeable. A 14.5 SEER system is approximately 11.5% more efficient than a 13 SEER system (calculated as (14.5 – 13) / 13 * 100%). This translates to tangible energy savings over time, especially in climates with long cooling seasons.
  • How long does it take for a higher SEER AC to pay for itself?
    The payback period varies greatly depending on the difference in SEER ratings, the cost of electricity in your area, climate, usage habits, and the upfront cost difference between the units. Generally, a system with a significantly higher SEER rating might pay for itself through energy savings within 5-10 years, but it can be shorter or longer. Use our energy savings calculator (link placeholder) for a more detailed analysis.
  • Can I upgrade my existing AC to have a higher SEER rating without changing the outdoor unit?
    No. The SEER rating is determined by the combination of the outdoor unit (condenser and compressor) and the indoor unit (evaporator coil). You must replace both components, or at least the matched set, to achieve a different SEER rating. Replacing only one part can lead to inefficient operation and void warranties.
  • What are ENERGY STAR certified HVAC systems?
    ENERGY STAR certified HVAC systems meet strict energy efficiency guidelines set by the U.S. Environmental Protection Agency (EPA). These systems are typically 10-15% more efficient than standard, minimum-efficiency models, offering significant energy and cost savings. They often have higher SEER ratings and incorporate other advanced efficiency features.
  • Does my SEER rating affect my home's comfort level?
    While SEER primarily measures efficiency, higher SEER systems often incorporate advanced technology that can improve comfort. This includes variable-speed compressors and fans that provide more consistent temperature control, better humidity removal, and quieter operation compared to single-stage systems found in lower SEER units.

Related Tools and Internal Resources

© 2023 Your Financial Website. All rights reserved.
var chartInstance = null; // Global variable to hold chart instance function calculateSeer() { var coolingCapacityInput = document.getElementById("coolingCapacity"); var seasonalEnergyInput = document.getElementById("seasonalEnergyInput"); var coolingCapacityError = document.getElementById("coolingCapacityError"); var seasonalEnergyInputError = document.getElementById("seasonalEnergyInputError"); var primaryResult = document.getElementById("primary-result"); var intermediateBtu = document.getElementById("intermediate-btu"); var intermediateWh = document.getElementById("intermediate-wh"); var intermediateKwh = document.getElementById("intermediate-kwh"); var coolingCapacity = parseFloat(coolingCapacityInput.value); var seasonalEnergyInputWh = parseFloat(seasonalEnergyInput.value); // Reset errors coolingCapacityError.textContent = ""; seasonalEnergyInputError.textContent = ""; primaryResult.textContent = "–"; intermediateBtu.innerHTML = ""; intermediateWh.innerHTML = ""; intermediateKwh.innerHTML = ""; // Input Validation if (isNaN(coolingCapacity) || coolingCapacity <= 0) { coolingCapacityError.textContent = "Please enter a valid cooling capacity (e.g., 36000)."; return; } if (isNaN(seasonalEnergyInputWh) || seasonalEnergyInputWh <= 0) { seasonalEnergyInputError.textContent = "Please enter a valid seasonal energy input (e.g., 3500)."; return; } var seasonalCoolingOutputBtu = coolingCapacity; // Assuming input is already BTU per season for simplicity in this calculator context, though often it's BTU/hr * hours. Re-labeling input for clarity. // If coolingCapacity is BTU/hr, we need seasonal hours. For this calculator, let's assume the user inputs total BTU for the season or understands coolingCapacity represents total seasonal BTU. // Let's refine the input label and helper text to clarify this common point of confusion. // For this implementation, we'll treat coolingCapacity input as total seasonal BTU output. var seerRating = (seasonalCoolingOutputBtu / seasonalEnergyInputWh) * 3.412; // Update results display if (!isNaN(seerRating)) { primaryResult.textContent = seerRating.toFixed(1); intermediateBtu.innerHTML = "Total Seasonal Cooling Output: " + seasonalCoolingOutputBtu.toLocaleString() + " BTU"; intermediateWh.innerHTML = "Total Seasonal Energy Input: " + seasonalEnergyInputWh.toLocaleString() + " Wh"; intermediateKwh.innerHTML = "Total Seasonal Energy Input: " + (seasonalEnergyInputWh / 1000).toLocaleString() + " kWh"; } else { primaryResult.textContent = "Error"; } updateChart(coolingCapacity); // Pass cooling capacity for chart reference } function resetCalculator() { document.getElementById("coolingCapacity").value = "36000"; // Example default: 3-ton AC document.getElementById("seasonalEnergyInput").value = "3500"; // Example default: ~3.5 kWh/season for 14 SEER 3-ton AC (very rough estimate) // Clear error messages document.getElementById("coolingCapacityError").textContent = ""; document.getElementById("seasonalEnergyInputError").textContent = ""; // Reset results display document.getElementById("primary-result").textContent = "–"; document.getElementById("intermediate-btu").innerHTML = ""; document.getElementById("intermediate-wh").innerHTML = ""; document.getElementById("intermediate-kwh").innerHTML = ""; // Reset chart if (chartInstance) { chartInstance.destroy(); chartInstance = null; } // Recalculate with default values calculateSeer(); } function copyResults() { var primaryResult = document.getElementById("primary-result").textContent; var intermediateBtu = document.getElementById("intermediate-btu").textContent; var intermediateWh = document.getElementById("intermediate-wh").textContent; var intermediateKwh = document.getElementById("intermediate-kwh").textContent; var formula = "Formula: SEER = Total Cooling Output (BTU) / Total Energy Input (Watt-hours) * 3.412"; var resultsText = "SEER Rating Calculator Results:\n\n"; resultsText += "Primary Result (SEER Rating):\n" + primaryResult + "\n\n"; resultsText += "Key Assumptions & Inputs:\n"; resultsText += "- " + intermediateBtu + "\n"; resultsText += "- " + intermediateWh + "\n"; resultsText += "- " + intermediateKwh + "\n\n"; resultsText += formula; // Use navigator.clipboard for modern browsers if (navigator.clipboard && navigator.clipboard.writeText) { navigator.clipboard.writeText(resultsText).then(function() { // Optional: Show a confirmation message alert("Results copied to clipboard!"); }).catch(function(err) { console.error("Failed to copy results: ", err); // Fallback for older browsers or if permission denied copyResultsFallback(resultsText); }); } else { copyResultsFallback(resultsText); } } function copyResultsFallback(text) { var textArea = document.createElement("textarea"); textArea.value = text; textArea.style.position = "fixed"; // Avoid scrolling to bottom of page in MS Edge. textArea.style.top = "0"; textArea.style.left = "0"; textArea.style.width = "2em"; textArea.style.height = "2em"; textArea.style.padding = "0"; textArea.style.border = "none"; textArea.style.outline = "none"; textArea.style.boxShadow = "none"; textArea.style.background = "transparent"; document.body.appendChild(textArea); textArea.focus(); textArea.select(); try { var successful = document.execCommand('copy'); var msg = successful ? 'successful' : 'unsuccessful'; // alert('Results copied ' + msg); // Optional confirmation } catch (err) { console.error('Fallback: Oops, unable to copy', err); alert("Could not copy results. Please copy manually."); } document.body.removeChild(textArea); } function updateChart(coolingCapacity) { var ctx = document.getElementById('seerChart').getContext('2d'); // Define SEER ratings to compare var seerRatings = [13, 14, 15, 16, 17, 18, 19, 20, 21, 22]; var estimatedEnergyConsumption = []; // in kWh // Assuming coolingCapacity is total seasonal BTU var seasonalCoolingOutputBtu = parseFloat(coolingCapacity); if (isNaN(seasonalCoolingOutputBtu) || seasonalCoolingOutputBtu <= 0) seasonalCoolingOutputBtu = 36000; // Default if invalid seerRatings.forEach(function(seer) { var energyWh = (seasonalCoolingOutputBtu / seer); // Simplified calculation: assumes total BTU output divided by SEER gives Wh input. var energyKwh = energyWh / 1000; estimatedEnergyConsumption.push(energyKwh); }); // Destroy previous chart instance if it exists if (chartInstance) { chartInstance.destroy(); } // Create new chart chartInstance = new Chart(ctx, { type: 'bar', // Use bar chart for better comparison of discrete values data: { labels: seerRatings.map(function(seer) { return seer + ' SEER'; }), datasets: [{ label: 'Estimated Seasonal Energy Consumption (kWh)', data: estimatedEnergyConsumption, backgroundColor: 'rgba(0, 74, 153, 0.6)', // Primary color borderColor: 'rgba(0, 74, 153, 1)', borderWidth: 1 }] }, options: { responsive: true, maintainAspectRatio: false, // Allow custom height scales: { y: { beginAtZero: true, title: { display: true, text: 'Estimated Energy Consumption (kWh)' } }, x: { title: { display: true, text: 'SEER Rating' } } }, plugins: { legend: { position: 'top', }, title: { display: true, text: 'Seasonal Energy Consumption vs. SEER Rating', font: { size: 16 } } } } }); } // Initialize calculator and chart on page load document.addEventListener('DOMContentLoaded', function() { // Set default values document.getElementById("coolingCapacity").value = "36000"; // 3-ton AC document.getElementById("seasonalEnergyInput").value = "3500"; // Example: represents ~3.5 kWh for a 14 SEER system over season calculateSeer(); // Perform initial calculation // Initialize FAQ toggles var faqQuestions = document.querySelectorAll('.faq-question'); faqQuestions.forEach(function(question) { question.addEventListener('click', function() { var answer = this.nextElementSibling; this.classList.toggle('active'); if (answer.style.display === 'block') { answer.style.display = 'none'; } else { answer.style.display = 'block'; } }); }); });

Leave a Comment