Voltage Calculator Drop

Voltage Drop Calculator & Guide – Calculate Electrical Wire Voltage Loss :root { –primary-color: #004a99; –success-color: #28a745; –background-color: #f8f9fa; –text-color: #333; –border-color: #ddd; –card-background: #fff; –shadow: 0 2px 5px rgba(0,0,0,0.1); } body { font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif; background-color: var(–background-color); color: var(–text-color); line-height: 1.6; margin: 0; padding: 0; } .container { max-width: 1000px; margin: 20px auto; padding: 20px; background-color: var(–card-background); border-radius: 8px; box-shadow: var(–shadow); } header { background-color: var(–primary-color); color: white; padding: 20px 0; text-align: center; margin-bottom: 20px; border-radius: 8px 8px 0 0; } header h1 { margin: 0; font-size: 2.2em; } .calculator-section { margin-bottom: 40px; padding: 30px; border: 1px solid var(–border-color); border-radius: 8px; background-color: var(–card-background); box-shadow: var(–shadow); } .calculator-section h2 { color: var(–primary-color); text-align: center; margin-top: 0; margin-bottom: 25px; } .input-group { margin-bottom: 20px; display: flex; flex-direction: column; align-items: flex-start; } .input-group label { display: block; margin-bottom: 8px; font-weight: bold; color: var(–primary-color); } .input-group input[type="number"], .input-group select { width: calc(100% – 20px); padding: 12px; border: 1px solid var(–border-color); border-radius: 4px; font-size: 1em; box-sizing: border-box; } .input-group input[type="number"]:focus, .input-group select:focus { outline: none; border-color: var(–primary-color); box-shadow: 0 0 0 2px rgba(0, 74, 153, 0.2); } .input-group .helper-text { font-size: 0.85em; color: #666; margin-top: 5px; } .input-group .error-message { color: red; font-size: 0.8em; margin-top: 5px; display: none; /* Hidden by default */ } .button-group { display: flex; justify-content: space-between; margin-top: 25px; gap: 10px; } .button-group button { padding: 12px 20px; border: none; border-radius: 5px; cursor: pointer; font-size: 1em; transition: background-color 0.3s ease; flex-grow: 1; } .btn-calculate { background-color: var(–primary-color); color: white; } .btn-calculate:hover { background-color: #003366; } .btn-reset { background-color: #6c757d; color: white; } .btn-reset:hover { background-color: #5a6268; } .btn-copy { background-color: #ffc107; color: #212529; } .btn-copy:hover { background-color: #e0a800; } #results-container { margin-top: 30px; padding: 25px; border: 1px solid var(–border-color); border-radius: 8px; background-color: var(–card-background); box-shadow: var(–shadow); text-align: center; } #results-container h3 { color: var(–primary-color); margin-top: 0; margin-bottom: 20px; } .result-item { margin-bottom: 15px; padding: 10px; border-radius: 5px; } .result-item:nth-child(odd) { background-color: #e9ecef; } .result-item span { font-weight: bold; font-size: 1.1em; } .primary-result { background-color: var(–success-color); color: white; padding: 15px; margin-bottom: 20px; border-radius: 5px; font-size: 1.5em; font-weight: bold; } .formula-explanation { font-size: 0.9em; color: #555; margin-top: 15px; padding-top: 15px; border-top: 1px dashed #ccc; } .chart-container { margin-top: 30px; padding: 25px; border: 1px solid var(–border-color); border-radius: 8px; background-color: var(–card-background); box-shadow: var(–shadow); text-align: center; } .chart-container h3 { color: var(–primary-color); margin-top: 0; margin-bottom: 20px; } canvas { max-width: 100%; height: auto; } .table-container { margin-top: 30px; padding: 25px; border: 1px solid var(–border-color); border-radius: 8px; background-color: var(–card-background); box-shadow: var(–shadow); overflow-x: auto; } .table-container h3 { color: var(–primary-color); margin-top: 0; margin-bottom: 20px; text-align: center; } table { width: 100%; border-collapse: collapse; margin-top: 15px; } th, td { padding: 12px 15px; text-align: left; border-bottom: 1px solid var(–border-color); } th { background-color: var(–primary-color); color: white; font-weight: bold; } tr:nth-child(even) { background-color: #f2f2f2; } caption { font-size: 0.9em; color: #555; margin-bottom: 10px; caption-side: top; text-align: left; } .article-section { margin-top: 40px; padding: 30px; border: 1px solid var(–border-color); border-radius: 8px; background-color: var(–card-background); box-shadow: var(–shadow); } .article-section h2, .article-section h3 { color: var(–primary-color); margin-bottom: 15px; } .article-section h2 { font-size: 1.8em; border-bottom: 2px solid var(–primary-color); padding-bottom: 5px; } .article-section h3 { font-size: 1.4em; margin-top: 25px; } .article-section p { margin-bottom: 15px; } .article-section ul, .article-section ol { margin-left: 20px; margin-bottom: 15px; } .article-section li { margin-bottom: 8px; } .faq-item { margin-bottom: 15px; padding: 10px; border-left: 3px solid var(–primary-color); background-color: #f0f8ff; border-radius: 4px; } .faq-item strong { color: var(–primary-color); } .internal-links { margin-top: 30px; padding: 25px; border: 1px solid var(–border-color); border-radius: 8px; background-color: var(–card-background); box-shadow: var(–shadow); } .internal-links h3 { color: var(–primary-color); margin-top: 0; margin-bottom: 20px; text-align: center; } .internal-links ul { list-style: none; padding: 0; } .internal-links li { margin-bottom: 10px; padding: 8px; border-bottom: 1px dashed #eee; } .internal-links li:last-child { border-bottom: none; } .internal-links a { color: var(–primary-color); text-decoration: none; font-weight: bold; } .internal-links a:hover { text-decoration: underline; } .internal-links p { font-size: 0.9em; color: #555; margin-top: 5px; } .highlight { background-color: var(–success-color); color: white; padding: 2px 5px; border-radius: 3px; } .error-highlight { border-color: red !important; } .tooltip { position: relative; display: inline-block; cursor: help; border-bottom: 1px dotted #004a99; } .tooltip .tooltiptext { visibility: hidden; width: 220px; background-color: #555; color: #fff; text-align: center; border-radius: 6px; padding: 5px 10px; position: absolute; z-index: 1; bottom: 125%; left: 50%; margin-left: -110px; opacity: 0; transition: opacity 0.3s; font-size: 0.85em; line-height: 1.4; } .tooltip .tooltiptext::after { content: ""; position: absolute; top: 100%; left: 50%; margin-left: -5px; border-width: 5px; border-style: solid; border-color: #555 transparent transparent transparent; } .tooltip:hover .tooltiptext { visibility: visible; opacity: 1; }

Voltage Drop Calculator

Calculate electrical wire voltage loss accurately and easily.

Voltage Drop Calculator

The electrical current flowing through the wire.
Resistance of the wire material per unit length (e.g., Ohms per meter or foot).
The total length of the wire run (same units as resistance per unit length).
The nominal voltage of the electrical system.

Calculation Results

Total Wire Resistance: Ohms
Voltage Drop (Volts): V
Voltage Drop (% of System Voltage): %
Voltage Drop: — V
Formula Used: Voltage Drop (Vd) = Current (I) × Total Wire Resistance (R_total)
Where R_total = Resistance per Unit Length × Wire Length × 2 (for round trip). Percentage Drop = (Voltage Drop / System Voltage) × 100.

Voltage Drop vs. Wire Length

This chart visualizes how voltage drop increases with wire length for the given current and wire resistance.

Wire Resistance Data (Approximate)

Approximate resistance values for common conductors at 20°C (per 1000 ft or 305 m). Use specific manufacturer data for precise calculations.
Conductor Material AWG/kcmil Resistance (Ohms/1000ft) Resistance (Ohms/km)
Copper146.3820.9
Copper124.0213.2
Copper102.538.30
Copper81.615.28
Aluminum126.3820.9
Aluminum104.0213.2
Aluminum82.538.30

What is Voltage Drop?

Voltage drop, often referred to as electrical voltage loss, is a fundamental concept in electrical engineering and a critical consideration for anyone designing or maintaining electrical systems. It represents the reduction in electrical potential (voltage) that occurs as current flows through a conductor, such as a wire or cable. This reduction is primarily due to the inherent resistance of the conductor material itself. Think of it like friction in a water pipe; as water flows, some energy is lost due to the pipe's resistance, slowing the flow. Similarly, as electrical current flows through a wire, the wire's resistance causes a portion of the electrical energy to be dissipated as heat, leading to a lower voltage at the destination compared to the source.

Who Should Use a Voltage Drop Calculator?

A voltage drop calculator is an indispensable tool for a wide range of professionals and DIY enthusiasts involved in electrical work. This includes:

  • Electricians: To ensure installations comply with electrical codes and to guarantee proper operation of equipment.
  • Electrical Engineers: For designing power distribution systems, sizing conductors, and optimizing system efficiency.
  • HVAC Technicians: To ensure motors and control systems receive adequate voltage for reliable operation.
  • Homeowners and DIYers: When extending circuits, installing new appliances, or setting up low-voltage systems (like landscape lighting) to prevent performance issues.
  • Industrial Maintenance Personnel: To troubleshoot power quality issues and maintain machinery.

Common Misconceptions about Voltage Drop

Several misunderstandings can lead to improper electrical system design:

  • "Voltage drop is always negligible": While it might be small in short, heavy-gauge wires, it becomes significant in longer runs or with smaller gauge wires, especially under heavy loads.
  • "Only AC systems experience voltage drop": Voltage drop occurs in both AC and DC circuits due to conductor resistance. The calculation method might vary slightly for AC due to impedance, but resistance is the primary factor.
  • "It's just a minor inconvenience": Excessive voltage drop can cause equipment malfunction, overheating, reduced efficiency, and even premature failure.
  • "Using thicker wire completely eliminates the problem": While thicker wires (lower gauge number) have less resistance, cost and installation constraints often necessitate finding an optimal balance.

Voltage Drop Formula and Mathematical Explanation

Understanding the voltage drop formula is key to using the calculator effectively and diagnosing electrical issues. The fundamental principle is Ohm's Law (V = I × R), applied to the resistance of the conductor.

Step-by-Step Derivation

  1. Calculate Total Wire Resistance (R_total): The resistance of a wire is proportional to its length and the resistivity of its material, and inversely proportional to its cross-sectional area. For simplicity in calculators, we often use a pre-defined resistance per unit length. Since current travels to the load and back, the total effective length is twice the physical length of the wire run.
    R_total = (Resistance per Unit Length) × (Wire Length) × 2
  2. Calculate Voltage Drop (Vd): Using Ohm's Law, the voltage drop across the total wire resistance is the product of the current flowing through it and the total resistance.
    Vd = Current (I) × R_total
  3. Calculate Percentage Voltage Drop: To understand the severity of the drop relative to the system's nominal voltage, we express it as a percentage.
    Percentage Drop = (Vd / System Voltage) × 100%

Variable Explanations

  • Current (I): The amount of electrical charge flowing per unit time, measured in Amperes (A). This is typically the maximum expected load current.
  • Resistance per Unit Length: The inherent resistance of the conductor material per unit of length (e.g., Ohms per meter or Ohms per foot). This depends on the material (copper, aluminum) and the wire gauge.
  • Wire Length: The total one-way distance from the power source to the load, measured in the same units used for resistance per unit length (e.g., meters or feet).
  • System Voltage (Vs): The nominal voltage supplied by the source (e.g., 120V, 240V, 12V DC).
  • Total Wire Resistance (R_total): The combined resistance of the wire conductor for the complete circuit path (go and return).
  • Voltage Drop (Vd): The amount of voltage lost due to the resistance of the wire.
  • Percentage Voltage Drop: The voltage drop expressed as a percentage of the system voltage.

Variables Table

Key Variables in Voltage Drop Calculation
Variable Meaning Unit Typical Range / Notes
ICurrentAmperes (A)0.1A to 1000A+ (depends on application)
RunitResistance per Unit LengthOhms/Unit Lengthe.g., 0.001 to 0.1 Ohms/meter; 0.0003 to 0.03 Ohms/foot
LWire LengthUnits (meters, feet)1 to 1000+ (depends on distance)
VsSystem VoltageVolts (V)1.5V (batteries) to 120V, 240V, 480V+ (mains)
RtotalTotal Wire ResistanceOhms (Ω)Calculated value, typically small (e.g., 0.1 to 10 Ω)
VdVoltage DropVolts (V)Calculated value, ideally < 3-5% of Vs
% DropPercentage Voltage Drop%0% to 100% (ideally < 3-5%)

Practical Examples (Real-World Use Cases)

Let's illustrate the importance of calculating voltage drop with practical scenarios:

Example 1: Landscape Lighting Circuit

Scenario: You're installing a 12V DC landscape lighting system. The transformer is located 100 feet away from the furthest light fixture. The total current draw for all lights on this run is 15 Amps. You're considering using 12 AWG copper wire, which has a resistance of approximately 0.004 Ohms per foot.

Inputs:

  • Current (I): 15 A
  • Wire Resistance per Unit Length: 0.004 Ohms/foot
  • Wire Length (L): 100 feet
  • System Voltage (Vs): 12 V

Calculation:

  • Total Wire Resistance (R_total) = 0.004 Ω/ft × 100 ft × 2 = 0.8 Ω
  • Voltage Drop (Vd) = 15 A × 0.8 Ω = 12 V
  • Percentage Drop = (12 V / 12 V) × 100% = 100%

Interpretation: A 100% voltage drop means the lights would receive virtually 0 volts! This is a critical failure. The wire is far too thin for the distance and current. You would need to significantly increase the wire gauge (e.g., to 8 AWG or even 6 AWG) or move the transformer closer to reduce the voltage drop.

Example 2: Workshop Power Outlet

Scenario: You need to run a 240V circuit to a new outlet in your workshop, 75 feet away. The outlet will power a welder that draws 30 Amps. You're considering 10 AWG copper wire (resistance approx. 0.00253 Ohms per foot).

Inputs:

  • Current (I): 30 A
  • Wire Resistance per Unit Length: 0.00253 Ohms/foot
  • Wire Length (L): 75 feet
  • System Voltage (Vs): 240 V

Calculation:

  • Total Wire Resistance (R_total) = 0.00253 Ω/ft × 75 ft × 2 = 0.3795 Ω
  • Voltage Drop (Vd) = 30 A × 0.3795 Ω = 11.385 V
  • Percentage Drop = (11.385 V / 240 V) × 100% = 4.74%

Interpretation: A 4.74% voltage drop is borderline. Many codes recommend keeping voltage drop below 3% for branch circuits and 5% for feeders. While the welder might function, its performance could be slightly degraded, and it's close to the acceptable limit. Using a thicker wire (e.g., 8 AWG) would reduce this drop further, ensuring optimal performance and compliance.

How to Use This Voltage Drop Calculator

Our voltage drop calculator is designed for simplicity and accuracy. Follow these steps:

  1. Identify Your Inputs: Gather the necessary information about your electrical circuit.
  2. Enter Current (Amps): Input the maximum expected current the circuit will carry. This is often determined by the load's power rating (Watts) and system voltage (Volts) using P=VI.
  3. Enter Wire Resistance: Find the resistance per unit length for your specific wire type (copper or aluminum) and gauge (AWG). This data is often found in electrical codebooks or manufacturer specifications. You can use the table provided as a reference, but always verify for your exact wire.
  4. Enter Wire Length: Measure the total one-way distance from the power source to the load. Ensure the units (e.g., feet, meters) match those used for the wire resistance.
  5. Enter System Voltage: Input the nominal voltage of your electrical system (e.g., 12V, 24V, 120V, 240V).
  6. Click Calculate: The calculator will instantly display the total wire resistance, the calculated voltage drop in Volts, and the percentage of voltage drop relative to the system voltage.

How to Read Results

  • Total Wire Resistance: A measure of how much the wire impedes current flow. Higher values mean more energy loss.
  • Voltage Drop (Volts): The actual amount of voltage lost along the wire.
  • Voltage Drop (%): This is the most crucial metric for determining acceptability. Generally, aim for less than 3% for branch circuits and 5% for feeders to ensure efficient and reliable operation of equipment.
  • Primary Result: A highlighted display of the calculated voltage drop in Volts for quick reference.

Decision-Making Guidance

Use the percentage voltage drop to make informed decisions:

  • < 3%: Generally acceptable for most circuits, especially lighting and sensitive electronics.
  • 3% – 5%: May be acceptable for motor loads or feeders, but consider upsizing the wire for better performance and efficiency.
  • > 5%: Unacceptable. You MUST increase the wire size (use a lower AWG number or larger kcmil), reduce the wire length, or decrease the current load to bring the voltage drop within acceptable limits.

Key Factors That Affect Voltage Drop Results

Several factors influence the amount of voltage drop in an electrical circuit. Understanding these helps in accurate calculation and system design:

  1. Conductor Resistance (Material & Gauge): This is the most direct factor. Copper has lower resistance than aluminum. Thicker wires (lower AWG numbers) have less resistance than thinner wires. The calculator uses resistance per unit length, which encapsulates both material and gauge.
  2. Wire Length: Voltage drop is directly proportional to the length of the wire. Longer runs result in higher resistance and thus greater voltage drop. This is why the "go and return" path is doubled in the calculation.
  3. Current Load: Voltage drop is directly proportional to the current flowing through the wire (Ohm's Law). Higher current demands lead to a larger voltage drop for the same wire resistance. Ensure you use the maximum expected load current.
  4. Temperature: The resistance of most conductors increases with temperature. While standard calculations often use a reference temperature (like 20°C or 75°C), significant temperature variations in the installation environment can slightly alter the actual voltage drop.
  5. Frequency (for AC circuits): In AC circuits, especially at higher frequencies or with larger conductors, inductive reactance and skin effect can add to the total impedance, slightly increasing the effective resistance and thus the voltage drop beyond what pure resistance calculations show. This calculator primarily focuses on resistive drop for simplicity, which is dominant in most low-frequency power applications.
  6. Connection Quality: Poorly made connections (loose terminals, corroded lugs, undersized splices) introduce additional resistance into the circuit. This "contact resistance" can significantly increase local voltage drop and create hotspots, posing a fire hazard.
  7. System Voltage: While not directly part of the Vd calculation, the system voltage is critical for determining the *acceptability* of the voltage drop. A 2V drop is minor on a 480V system (0.4%) but significant on a 12V system (16.7%).

Frequently Asked Questions (FAQ)

Q1: What is the maximum acceptable voltage drop?
A1: Electrical codes often recommend a maximum of 3% voltage drop for branch circuits (from the panel to the outlet/fixture) and 5% total voltage drop for feeders and branch circuits combined (from the service entrance). However, specific applications might have tighter requirements.
Q2: Does voltage drop affect AC and DC circuits differently?
A2: The fundamental cause (resistance) is the same. However, AC circuits also have impedance (reactance from inductance and capacitance), and effects like the skin effect (current concentrating on the conductor's surface at higher frequencies) can slightly alter the effective resistance. This calculator primarily uses resistive calculations, suitable for most common AC and DC power distribution scenarios.
Q3: Can I use the voltage drop percentage for my 12V system?
A3: Yes, absolutely. Low-voltage systems (like automotive, solar, or landscape lighting) are often *more* sensitive to voltage drop because the absolute voltage is so low. A 5% drop on 12V is only 0.6V, but it can significantly impact performance. Always use the percentage calculation relative to the system voltage.
Q4: What happens if the voltage drop is too high?
A4: High voltage drop can lead to under-powered equipment (dim lights, slow motors, malfunctioning electronics), increased energy waste (dissipated as heat in the wires), and potentially overheating of conductors and connections, posing a fire risk.
Q5: How does wire material (copper vs. aluminum) affect voltage drop?
A5: Copper has significantly lower resistivity than aluminum. This means for the same gauge and length, a copper wire will have less resistance and therefore a lower voltage drop compared to an aluminum wire. Copper is generally preferred for smaller gauge wires due to its conductivity and ease of termination.
Q6: Should I use the length of the conduit or the wire length?
A6: Always use the actual length of the wire run. If the wire is pulled through a conduit, the wire length might be longer than the conduit length due to slack or bends. Measure the wire path carefully.
Q7: Does the calculator account for wire temperature?
A7: This calculator uses standard resistance values typically based on a reference temperature (e.g., 20°C). Actual resistance varies with temperature. For installations in extreme temperatures, you might need to consult more detailed engineering tables or use temperature-adjusted resistance values.
Q8: What is "resistance per unit length"?
A8: It's a property of the wire material and its cross-sectional area (gauge). It tells you how much resistance a specific length of that wire offers. Common units are Ohms per 1000 feet (Ω/1000ft) or Ohms per kilometer (Ω/km). Ensure your input units match the data you use.
© 2023 Your Website Name. All rights reserved. Disclaimer: This calculator provides estimates. Always consult with a qualified electrician and adhere to local electrical codes.
var chartInstance = null; // Global variable to hold chart instance function getElement(id) { return document.getElementById(id); } function validateInput(inputId, errorId, minValue, maxValue, unit) { var input = getElement(inputId); var errorElement = getElement(errorId); var value = parseFloat(input.value); var isValid = true; errorElement.style.display = 'none'; input.classList.remove('error-highlight'); if (isNaN(value)) { errorElement.textContent = 'Please enter a valid number.'; errorElement.style.display = 'block'; input.classList.add('error-highlight'); isValid = false; } else if (value maxValue) { errorElement.textContent = 'Value is too high. Max allowed: ' + maxValue + ' ' + unit; errorElement.style.display = 'block'; input.classList.add('error-highlight'); isValid = false; } return isValid ? value : null; } function calculateVoltageDrop() { var current = validateInput('current', 'currentError', 0); var resistancePerUnitLength = validateInput('resistancePerUnitLength', 'resistancePerUnitLengthError', 0); var wireLength = validateInput('wireLength', 'wireLengthError', 0); var systemVoltage = validateInput('systemVoltage', 'systemVoltageError', 1); // System voltage must be at least 1V if (current === null || resistancePerUnitLength === null || wireLength === null || systemVoltage === null) { // Clear results if validation fails getElement('totalWireResistance').textContent = '–'; getElement('voltageDrop').textContent = '–'; getElement('voltageDropPercentage').textContent = '–'; getElement('primaryResult').textContent = 'Voltage Drop: — V'; if (chartInstance) { chartInstance.destroy(); chartInstance = null; } return; } var totalWireResistance = resistancePerUnitLength * wireLength * 2; var voltageDrop = current * totalWireResistance; var voltageDropPercentage = (voltageDrop / systemVoltage) * 100; getElement('totalWireResistance').textContent = totalWireResistance.toFixed(4); getElement('voltageDrop').textContent = voltageDrop.toFixed(2); getElement('voltageDropPercentage').textContent = voltageDropPercentage.toFixed(2); getElement('primaryResult').textContent = 'Voltage Drop: ' + voltageDrop.toFixed(2) + ' V'; updateChart(wireLength, voltageDrop); } function resetCalculator() { getElement('current').value = '10'; getElement('resistancePerUnitLength').value = '0.001'; getElement('wireLength').value = '50'; getElement('systemVoltage').value = '120'; // Clear errors getElement('currentError').style.display = 'none'; getElement('resistancePerUnitLengthError').style.display = 'none'; getElement('wireLengthError').style.display = 'none'; getElement('systemVoltageError').style.display = 'none'; getElement('current').classList.remove('error-highlight'); getElement('resistancePerUnitLength').classList.remove('error-highlight'); getElement('wireLength').classList.remove('error-highlight'); getElement('systemVoltage').classList.remove('error-highlight'); calculateVoltageDrop(); // Recalculate with default values } function copyResults() { var currentVal = getElement('current').value; var resPerUnitVal = getElement('resistancePerUnitLength').value; var lengthVal = getElement('wireLength').value; var sysVoltVal = getElement('systemVoltage').value; var totalRes = getElement('totalWireResistance').textContent; var voltDrop = getElement('voltageDrop').textContent; var voltDropPerc = getElement('voltageDropPercentage').textContent; var resultsText = "— Voltage Drop Calculation Results —\n\n"; resultsText += "Inputs:\n"; resultsText += "- Current: " + currentVal + " A\n"; resultsText += "- Resistance per Unit Length: " + resPerUnitVal + " Ohms/Unit\n"; resultsText += "- Wire Length: " + lengthVal + " Units\n"; resultsText += "- System Voltage: " + sysVoltVal + " V\n\n"; resultsText += "Calculated Values:\n"; resultsText += "- Total Wire Resistance: " + totalRes + " Ohms\n"; resultsText += "- Voltage Drop: " + voltDrop + " V\n"; resultsText += "- Voltage Drop Percentage: " + voltDropPerc + " %\n\n"; resultsText += "Formula: Vd = I * (R_unit * L * 2); %Drop = (Vd / Vs) * 100"; // Use a temporary textarea to copy text var textArea = document.createElement("textarea"); textArea.value = resultsText; textArea.style.position = "fixed"; textArea.style.left = "-9999px"; document.body.appendChild(textArea); textArea.focus(); textArea.select(); try { var successful = document.execCommand('copy'); var msg = successful ? 'Results copied!' : 'Copy failed!'; alert(msg); } catch (err) { alert('Oops, unable to copy'); } document.body.removeChild(textArea); } function updateChart(currentLength, currentDrop) { var ctx = getElement('voltageDropChart').getContext('2d'); // Destroy previous chart instance if it exists if (chartInstance) { chartInstance.destroy(); } // Generate data points for the chart (e.g., 5 points from 0 to currentLength) var dataPoints = []; var step = currentLength / 4; // Create 5 points including start and end for (var i = 0; i 0 && dataPoints[dataPoints.length – 1].length !== currentLength) { var resistancePerUnitLength = parseFloat(getElement('resistancePerUnitLength').value); var current = parseFloat(getElement('current').value); var calculatedDrop = current * (resistancePerUnitLength * currentLength * 2); dataPoints.push({ length: currentLength, drop: calculatedDrop }); } var labels = dataPoints.map(function(point) { return point.length.toFixed(0); }); var voltageDrops = dataPoints.map(function(point) { return point.drop.toFixed(2); }); chartInstance = new Chart(ctx, { type: 'line', data: { labels: labels, datasets: [{ label: 'Voltage Drop (V)', data: voltageDrops, borderColor: 'var(–primary-color)', backgroundColor: 'rgba(0, 74, 153, 0.1)', fill: true, tension: 0.1 }] }, options: { responsive: true, maintainAspectRatio: false, scales: { x: { title: { display: true, text: 'Wire Length (Units)' } }, y: { title: { display: true, text: 'Voltage Drop (Volts)' }, beginAtZero: true } }, plugins: { legend: { position: 'top', }, title: { display: true, text: 'Voltage Drop vs. Wire Length' } } } }); } // Initial calculation on page load window.onload = function() { calculateVoltageDrop(); };

Leave a Comment